BS 5540-6-1990 Evaluating particulate contamination of hydraulic fluids - Method of calibrating liquid automatic particle-count instruments (using mono-sized latex spheres)《液压油颗粒污染.pdf
《BS 5540-6-1990 Evaluating particulate contamination of hydraulic fluids - Method of calibrating liquid automatic particle-count instruments (using mono-sized latex spheres)《液压油颗粒污染.pdf》由会员分享,可在线阅读,更多相关《BS 5540-6-1990 Evaluating particulate contamination of hydraulic fluids - Method of calibrating liquid automatic particle-count instruments (using mono-sized latex spheres)《液压油颗粒污染.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 5540-6: 1990 Evaluating particulate contamination of hydraulic fluids Part 6: Method of calibrating liquid automatic particle-count instruments (using mono-sized latex spheres)BS5540-6:1990 This British Standard, having been prepared under the directionof the Machinery andCompone
2、nts Standards PolicyCommittee, was publishedunder the authorityofthe Board of BSIandcomes intoeffect on 31 December 1990 BSI 07-1999 The following BSI references relate to the work on this standard: Committee reference MCE/18 Draft for comment 88/72515 DC ISBN 0 580 19178 8 Committees responsible fo
3、r this British Standard The preparation of this British Standard was entrusted by the Machinery and Components Standards Policy Committee (MCE/-) to Technical Committee MCE/18, upon which the following bodies were represented: Advanced Manufacturing Technology Research Institute Association of Briti
4、sh Mining Equipment Companies Bath University Library British Compressed Air Society British Fluid Power Association British Steel Industry Department of Trade and Industry (National Engineering Laboratory) Institution of Mechanical Engineers Ministry of Defence The following bodies were also repres
5、ented in the drafting of the standard, through subcommittees and panels: British Hydromechanics Research Association British Railways Board Society of Motor Manufacturers and Traders Ltd. Amendments issued since publication Amd. No. Date CommentsBS5540-6:1990 BSI 07-1999 i Contents Page Committees r
6、esponsible Inside front cover Foreword ii 0 Introduction 1 1 Scope 1 2 Definitions 1 3 Apparatus 2 4 Materials 2 5 Preliminary procedures 3 6 Calibration procedures 4 Figure 1 Typical example of percentage distribution curve for38.8m spheres 7 Publication(s) referred to Inside back coverBS5540-6:199
7、0 ii BSI 07-1999 Foreword This Part of BS5540 has been prepared under the direction of the Machinery and Components Standards Policy Committee and is one of a series relating to the evaluation of particulate contamination in hydraulic fluids. This Part of BS5540 describes a method of calibrating liq
8、uid automatic particle counters working on the light obscuration principle, using mono-sized latex spheres. Other Parts in the series are as follows. Part 1: Qualifying and controlling of cleaning methods for sample containers; Part 2: Method of calibrating liquid automatic particle-count instrument
9、s (using AC Fine Test Dust contaminant); Part 3: Methods of bottling fluid samples; Part 4: Method of defining levels of contamination (solid contamination code); Part 5: Method of reporting contamination analysis data. A British Standard does not purport to include all the necessary provisions of a
10、 contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages1 to8, an inside back
11、 cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS5540-6:1990 BSI 07-1999 1 0 Introduction In hydraulic fluid power applications power is transmitted and con
12、trolled through a liquid under pressure within an enclosed circuit. The liquid is both a lubricant and power-transmitting medium. The presence of solid contamination particles in the liquid interferes with the ability of the fluid to lubricate and causes wear to the hydraulic components. The extent
13、of contamination in the liquid has a direct bearing on the performance and reliability of the system and has to be controlled to levels that are considered appropriate for the system. Quantitative determination of particulate contamination requires precision in obtaining the sample and determining t
14、he extent of contamination. The liquid automatic particle counter working on the light obscuration principle has become an accepted means of determining the extent of contamination. The accuracy of repeatability and reproducibility of particle count data is affected by both the procedures used and t
15、he method of calibration. 1 Scope This Part of BS5540 describes a method for the calibration of liquid automatic particle counters (APCs) working on the light obscuration principle. It establishes a uniform and precise method of calibrating these instruments which will enhance the degree of reproduc
16、ibility of particle count data between laboratories. The calibration material used is mono-sized latex spheres whose size can be verified by a number of different methods. The particle size parameter reported is the equivalent optical diameter based upon the projected area of a spherical particle. T
17、he method described first confirms the maximum concentration limits of the instrument being calibrated, verifies the particle size distribution of the latex spheres and, finally, enables the instrument to be calibrated in an accurate and precise manner. The calibration curve of an APC is the referen
18、ce that relates the particle size to the electrical threshold settings of the instrument. The development of the calibration curve is of primary importance in establishing the accurate sizing of particles being counted. A procedure is described that enables the voltage threshold value for any partic
19、le size within the sizing range of the sensor to be obtained. This method is intended for application to any APC working on the light obscuration principle in which particles interrupt the passage of light from a source to a detector. It assumes that the counter is equipped with at least two channel
20、s with adjustable voltage thresholds. Although this Part of BS5540 is intended for fluid power applications, it may also be applicable to other fields where this method of calibration is considered appropriate. NOTEThe titles of the publications referred to in this standard are listed on the inside
21、back cover. 2 Definitions For the purposes of this Part of BS5540 the following definitions apply. 2.1 agglomerate two or more particles that are in intimate contact and can not be separated by the small shear forces generated by gentle stirring 2.2 channel a particle size range as set into the liqu
22、id automatic particle counter 2.3 coincidence the presence of more than one particle within the sensing volume at the same time 2.4 dynamic sizing range the diameter of the smallest particle detected compared to the diameter of the largest particle passing through the sensor NOTEThis is usually quot
23、ed by the instrument manufacturer. 2.5 equivalent optical diameter the diameter reported by the counting/sizing device in use. It is the diameter of a sphere giving the same optical response as the particle 2.6 light obscuration the reduction of intensity of a light beam through the sensing volume c
24、aused by adsorption and/or scattering of the light by a single particle 2.7 minimum particle size the diameter of the smallest latex sphere used in the calibration procedure that is also within the size range that can be resolved by the counterBS5540-6:1990 2 BSI 07-1999 2.8 mono-sized latex spheres
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS554061990EVALUATINGPARTICULATECONTAMINATIONOFHYDRAULICFLUIDSMETHODOFCALIBRATINGLIQUIDAUTOMATICPARTICLECOUNTINSTRUMENTSUSINGMONOSIZEDLATEXSPHERES

链接地址:http://www.mydoc123.com/p-545176.html