BS 2690-117-1983 Methods of testing water used in industry - Long-chain fatty amines spectrophotometric method《工业用水试验方法 第117部分 长链脂肪胺 分光光度法》.pdf
《BS 2690-117-1983 Methods of testing water used in industry - Long-chain fatty amines spectrophotometric method《工业用水试验方法 第117部分 长链脂肪胺 分光光度法》.pdf》由会员分享,可在线阅读,更多相关《BS 2690-117-1983 Methods of testing water used in industry - Long-chain fatty amines spectrophotometric method《工业用水试验方法 第117部分 长链脂肪胺 分光光度法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 2690-117: 1983 Methods of testing Water used in industry Part 117: Long-chain fatty amines: spectrophotometric method IMPORTANT NOTE. It is essential that this Part be read in conjunction with the information in Part 100 of this standard, “Foreword, scope and general requirements
2、”, which is published separately. UDC 628.1:663.63.01:543.3:543.42.062:547.233BS2690-117:1983 This British Standard, having been prepared under the directionof the Environment andPollution Standards Committee, was published underthe authority of the BoardofBSI and comes intoeffecton 31 May 1983 BSI
3、07-1999 The following BSI references relate to the work on this standard: Committee reference EPC/37 Special announcement in BSINews March 1983 ISBN 0 580 11973 4 A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for
4、 their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages1 and 2, an inside back cover and a back cover. This standard has been updated
5、 (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date of issue CommentsBS 2690-117:1983 BSI 07-1999 i Contents Page 0 Introduction 1 1 Scope 1 2 Range 1 3 Principle 1
6、4 Interferences 1 5 Reagents 1 6 Treatment of apparatus 1 7 Sampling 1 8 Preparation of calibration graph 2 9 Procedure 2 10 Calculation 2 Publications referred to Inside back coverii blankBS2690-117:1983 BSI 07-1999 1 0 Introduction BS 2690-115, BS 2690-116 and BS 2690-117 together supersede BS 269
7、0-8:1969. This Part is a revision of clause 4. 1 Scope The method described is for the determination of long-chain fatty amines in industrial waters by a spectrophotometric method. 2 Range From 5 4g to 200 4g of long-chain fatty amine, expressed as octadecylamine, in a test portion not exceeding 100
8、 mL. 3 Principle The primary, secondary and tertiary forms of long-chain fatty amines react with methyl orange atpH 3 to 4 to form yellow complexes which are extracted into dichloromethane and determined colorimetrically. The calibration graph is prepared with the fatty amine that is added to the st
9、eam plant under investigation. As octadecylamine is the most commonly added fatty amine, it is used in the following method. 4 Interferences Cyclohexylamine, morpholine and ammonia do not interfere. Detergents interfere seriously and shall not be used for cleaning any glassware used in the test. 5 R
10、eagents 5.1 Buffer solution. Dissolve 125 g of potassium chloride and 70 g of sodium acetate trihydrate in500 mL of water. Add 300 mL of glacial acetic acid and dilute to 1 L with water. The pH value is 3.4. 5.2 Dichloromethane WARNING. Dichloromethane is harmful by inhalation. Avoid breathing its v
11、apour and contact with skin and eyes. 5.3 Propan-2-ol 5.4 Methyl orange solution. Dissolve 100 mg of methyl orange in 200 mL of water and add 50 mL of industrial methylated spirits (see 3.8 of BS 2690-100:1978). 5.5 Octadecylamine standard solutions 5.5.1 Octadecylamine stock solution. Weigh 0.500 g
12、 of octadecylamine into a 250 mL beaker, add 50 mL of glacial acetic acid and stir to dissolve. Transfer the solution to a 500 mL one-mark volumetric flask and dilute to the mark with water. Mix well. 5.5.2 Octadecylamine working solution. Dilute10.0mL of the octadecylamine stock solution(5.5.1) wit
13、h water to the mark in a1000mL one-mark volumetric flask(1mLN 104g of octadecylamine). Prepare this solution fresh before each calibration. 6 Treatment of apparatus Long-chain fatty amines tend to be absorbed on to glass surfaces and therefore all glassware apart from the optical cells shall be sili
14、cone-coated. This can be done by first cleaning the glassware with chromic acid and then rinsing the clean and dry surface of the glassware with a proprietary silicone emulsion, in accordance with the manufacturers instructions. The coating will usually last for about6 months and the glassware shall
15、 be re-treated when a normal water meniscus appears. 7 Sampling If the temperature of the water being sampled is above 30 C, the sampling line shall contain a small, permanently fixed, stainless steel cooling coil capable of reducing the temperature of the sample to about 25 C to 30 C. The sampling
16、line shall be kept as short as possible and the sample allowed to run to waste for at least 30 min before collection. Run the sample into a stoppered 250 mL silicone-coated glass bottle and analyse immediately.BS2690-117:1983 2 BSI 07-1999 8 Preparation of calibration graph Add 0, 1.0, 2.0, 5.0, 10.
17、0, 15.0 and 20.0 mL of the octadecylamine working solution (5.5.2) to a series of 150 mL separating funnels. This will correspond to 0, 10, 20, 50, 100, 150 and 200 4g of octadecylamine in a separating funnel. Treat the contents of each funnel as follows. Dilute to 100 mL with water, add 4.0 mL of t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS26901171983METHODSOFTESTINGWATERUSEDININDUSTRYLONGCHAINFATTYAMINESSPECTROPHOTOMETRICMETHOD 工业用水 试验

链接地址:http://www.mydoc123.com/p-543209.html