ATIS 0300085-2008 Test Specification for Product Label Scanning.pdf
《ATIS 0300085-2008 Test Specification for Product Label Scanning.pdf》由会员分享,可在线阅读,更多相关《ATIS 0300085-2008 Test Specification for Product Label Scanning.pdf(20页珍藏版)》请在麦多课文档分享上搜索。
1、 ATIS-0300085 ATIS Standard on - TEST SPECIFICATION FOR PRODUCT LABEL SCANNING As a leading technology and solutions development organization, ATIS brings together the top global ICT companies to advance the industrys most-pressing business priorities. Through ATIS committees and forums, nearly 200
2、companies address cloud services, device solutions, emergency services, M2M communications, cyber security, ehealth, network evolution, quality of service, billing support, operations, and more. These priorities follow a fast-track development lifecycle from design and innovation through solutions t
3、hat include standards, specifications, requirements, business use cases, software toolkits, and interoperability testing. ATIS is accredited by the American National Standards Institute (ANSI). ATIS is the North American Organizational Partner for the 3rd Generation Partnership Project (3GPP), a fou
4、nding Partner of oneM2M, a member and major U.S. contributor to the International Telecommunication Union (ITU) Radio and Telecommunications sectors, and a member of the Inter-American Telecommunication Commission (CITEL). For more information, visit. Notice of Disclaimer however, individual compani
5、es may inform the manufacturer of test results. This test specification does not intend to test for battery life, ergonomics, reliability of data. D.4 Expected Results The expected results of all tests for imagers or lasers are: 2. resolution of scanner the ability to read 5 mil and 7 mil symbols 3.
6、 determination of difficulty in reading a symbol first scan yield 4. determination of missed or duplicate scans to help determine the accuracy of the scanner 5. performance on symbols that are close together and symbols that are far apart is similar ATIS-0300085 6 D.5 Submission of Test Data The fol
7、lowing shall be returned to the ATIS once testing is complete: 1. Appendix A Scanner Information Worksheet. A separate form should be completed for each scanner used in testing. 2. Appendix B Scanner Test Reporting Worksheet. A separate form should be completed for each test performed. 3. Saved Data
8、 Capture Spreadsheet. See Appendix C for specific instructions on using the Data Capture Spreadsheet for data capture. 4. Test Panel. If test panel is lost or damaged, company that was in possession of the panel will either recreate or replace the test panel. The estimated cost to replace the panel
9、from a third party supplier is $600. Contact the BCSC Committee Administrator, for more information on the recreation or replacement of the panel. The packaging used to ship the Test Panel to the company participating in testing should be reused to return items to AIDC. The Test Panel shipment shoul
10、d be insured for $600. The items above should be returned to: AIDC Committee Administrator 1200 G Street NW, Suite 500 Washington, DC 20005 (202) 628-6380 or via email at AIDCatis.org. ATIS-0300085 7 Test: Preliminary Setup Procedures TITLE: Preliminary Setup Procedure Scan Symbols on Panel PURPOSE:
11、 To ensure that the setup and configuration of readers begins at a known point and to verify data transmission is enabled. PRE-TEST CONDITIONS (Environment): Scanners should not transmit non printable characters. CONFIGURATION: The scanner should be configured to factory defaults and then optimized
12、for best read performance. The scanner should be configured to block transmissions of characters ASCII DEC less than 032 (block non printable character transmissions) and transmit an Enter key event after each symbol transmission. To ensure optimal performance of the Data Matrix symbology by all ima
13、gers, the rectangular form of Data Matrix shall be turned off for these tests. TARGETING ZONE SETTING (If applicable): Not needed for preliminary setup testing. TEST DESCRIPTION: 1. Person performing these preliminary setup procedures should be the person performing testing. The purpose of this prel
14、iminary setup procedure is to accustom the tester to using the scanner. 2. Person using the scanner will scan all symbols from left to right beginning with the top row, as noted in D.1, Test Process. 3. Person using the scanner should verify that the scanner is reading and transmitting the data. a.
15、If there is difficulty reading and/or transmitting data with the scanner being used, person scanning should consider if adjustments are needed, if the scanner should be used for testing, or if a different scanner should be selected to perform testing. Person performing testing may also consider cont
16、acting the manufacturer for further assistance. b. If the person performing testing is satisfied with scanner performance, proceed with testing. 4. See Appendix C for instructions on the Data Capture Spreadsheet configuration. EXPECTED RESULT: 1. Determination of scanner to be used for testing. 2. H
17、elping the person performing scanning to accustom themselves to the use of the scanner. ATIS-0300085 8 Test #1: Depth of Field test REFERENCE: TITLE: Depth of Field test PURPOSE: Determine ease of use of the scanner to scan plug in cards in a central office environment. PRE-TEST CONDITIONS: Environm
18、ent: Describe the lighting conditions in the area that the test is performed on the Scanner Information Worksheet, located in Appendix A. CONFIGURATION: Ensure that the reader is configured in optimal setup for performance on test symbols. Make note of all non-default settings in Appendix A TEST DES
19、CRIPTION: 1. Select several test samples of differing size and density on the Test Matrix 2. Maintain orientation of the scanner and determine closest range and farthest range which the scanner is capable of decoding each symbol 3. Determine “sweet spot” where performance is optimal 4. Reorient the
20、same code and calculate near and far as well as optimal distance EXPECTED RESULT: 1. Depth of Field on properly configured Imagers will be slightly less than that of laser scanners. ATIS-0300085 9 Test #2: Imager Test #1 TITLE: Imager Test Scan All Symbols on Panel PURPOSE: To analyze the ability of
21、 imagers to scan plug in cards in a central office environment. PRE-TEST CONDITIONS (Environment): Describe the lighting conditions in the area that the test is performed on the Scanner Information Worksheet, located in Appendix A. CONFIGURATION: Describe the interface type on the Scanner Informatio
22、n Worksheet, located in Appendix A. User should perform the Preliminary Setup Procedures to ensure that data is being transmitted correctly to the Data Capture Spreadsheet. Ensure that the reader is configured in optimal setup for performance on test symbols. Make note of all non-default settings on
23、 the Scanner Information Worksheet in Appendix A. NOTE: Data Matrix and MicroPDF417 shall be ENABLED. Performance is impacted by these symbologies. TARGETING ZONE SETTING (If applicable): If your scanner has a targeting zone setting, please provide the setting on the Scanner Information Worksheet, l
24、ocated in Appendix A. TEST DESCRIPTION: 1. Person not performing scanning should record the start and stop time of Imager Test #1, approximate distance from the face of the scanner to the symbol, as well as note any difficulties that the person scanning symbols is having capturing content. The start
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ATIS03000852008TESTSPECIFICATIONFORPRODUCTLABELSCANNINGPDF

链接地址:http://www.mydoc123.com/p-541005.html