1、Designation: G 51 95 (Reapproved 2005)Standard Test Method forMeasuring pH of Soil for Use in Corrosion Testing1This standard is issued under the fixed designation G 51; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of l
2、ast revision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a procedure for determining thepH of a soil in corrosion testing. The principle use of the tes
3、tis to supplement soil resistivity measurements and therebyidentify conditions under which the corrosion of metals in soilmay be accentuated (see G 57 78 (1984).1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the us
4、er of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE 691 Practice for Conducting an Inte
5、rlaboratory Study toDetermine the Precision of a Test MethodG57 Method for Field Measurement of Soil ResistivityUsing the Wenner Four-Electrode Method3. Significance and Use3.1 Information on pH of soil is used as an aid in evaluatingthe corrosivity of a soil environment. Some metals are moresensiti
6、ve to the pH of their environment than others, andinformation on the stability of a metal as a function of pH andpotential is available in the literature.34. Apparatus4.1 pH MetersA portable, battery-powered pH meter isnecessary for field measurements. Most instruments can alsofunction as a high-imp
7、edance voltmeter. An LCD display ispreferred for its readability in a bright, outdoor environment.4.2 Calomel and Glass Electrodes:4.2.1 Use a saturated calomel reference electrode or itsequivalent in the pH determination. A few crystals of solidpotassium chloride should always be present within the
8、 cham-ber surrounding the calomel to assure that the solution issaturated under the conditions of use. The design of theelectrode must permit the formation of a fresh liquid junctionbetween the solution of potassium chloride and the buffer ortest soil for each test and allow traces of soil to be rea
9、dilyremoved by washing.4.2.2 A glass electrode of rugged construction is required.The performance of the glass electrode is satisfactory if itfurnishes the correct pH value (60.1 pH unit) for standardbuffered solutions.4.2.3 A combination electrode consisting of a saturatedcalomel reference electrod
10、e and a glass electrode (4.2.1 and4.2.2) combined as a single electrode is acceptable. However,the requirements outlined above are equally applicable to theelectrodes used in this combination unit.4.3 Subsurface ProbeWhen pH measurements below thesurface of the soil are required, it is necessary to
11、use a probe ofsuitable length which will allow measurements to be made atthe depth of interest. This probe consists of a glass electrode ora combination electrode in a rubber housing at the end of aplastic tube. One type of probe is illustrated in Fig. 1.4.4 Soil ThermometerSome pH electrodes have t
12、empera-ture compensation built in as part of the pH electrode, but mostdo not (see manufacturers specifications). A thermometer ofrugged construction is required for soil use, and a stainlesssteel sheathed thermometer is preferred. Metal sheathed ther-mometers come in different lengths, and a length
13、 appropriatefor the depth of interest should be chosen.5. Reagents and Materials5.1 During the calibration procedure for the pH meter,standard buffered solutions of known pH are necessary. Thesesolutions, or tablets to make up these solutions, can bepurchased from chemical supply companies or pH equ
14、ipmentmanufacturers.6. Sampling6.1 By the nature of the measurement, pH is determined fora small volume of soil at each reading, and it is important thatat least three measurements at different locations be made and1This test method is under the jurisdiction of ASTM Committee G01 onCorrosion of Meta
15、ls, and is the direct responsibility of Subcommittee G01.10 onCorrosion in Soils.Current edition approved Oct. 1, 2005. Published October 2005. Originallyapproved in 1977. Last previous edition approved in 2000 as G 51 95 (2000).2For referenced ASTM standards, visit the ASTM website, www.astm.org, o
16、rcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Pourbaix, M., “Atlas of Electrochemical Equilibria in Aqueous Solutions,”Pergamon Press, 1966.1Copyright ASTM International, 100 Ba
17、rr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.a simple average calculated. The regions of interest, surface,subsurface, or both, where applicable, must be sampled.7. Calibration and Standardization7.1 Test for LinearityPrior to field use, or periodicallywhen used exte
18、nsively in the field, test the apparatus forlinearity of response. This procedure is as follows:7.1.1 Turn on the instrument, allow to warm up thoroughly,and bring to electrical balance in accordance with the manu-facturers instructions. Before use, clean and rinse the glass andcalomel electrodes in
19、 distilled water.47.1.2 At least two standard buffered pH solutions that spanthe soil pH to be measured are required. From practicalexperience standard solutions of pH 4, 7, and 8 are recom-mended. For the test, the temperature of these solutions shallnot differ from each other by more than 5C. A la
20、boratorythermometer can be used for these measurements.7.1.3 Adjust the temperature compensating dial on the pHmeter to the standard solution temperature.7.1.4 Immerse the electrodes in a small volume of the firstknown standard solution. Now adjust the pH meter to read thisknown pH.7.1.5 Remove the
21、electrodes from the first standard solution,and rinse in distilled water. Immerse the electrodes in thesecond known standard solution and read the pH value. Judgethe system to be operating satisfactorily if the reading obtainedfor the second standard agrees within 60.1 unit of the assignedpH.7.2 Cal
22、ibration of pH MeterCalibrate the pH meter im-mediately before use. If a series of measurements are to bemade, repeat the calibration procedure at intervals of about 30min. Perform the pH meter calibration as follows:7.2.1 Use a standard pH solution in the range of the pH ofthe soil to be tested, if
23、 such information is known beforehand.Otherwise, begin with a standard solution having a pH of 7.Stabilize the temperature of the solution so that it matches thetemperature of the soil to within 10C.7.2.2 Immerse the electrodes in the known standard solutionand calibrate the meter in accordance with
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMG5119952005STANDARDTESTMETHODFORMEASURINGPHOFSOILFORUSEINCORROSIONTESTING 测量 腐蚀 试验 土壤 PH 测试 方法 PDF

链接地址:http://www.mydoc123.com/p-540649.html