《ASTM F2865-2013 Standard Guide for Classifying the Degrees of Ingress of Dust and Water into a Membrane Switch《灰尘和水对膜片开关浸入程度的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2865-2013 Standard Guide for Classifying the Degrees of Ingress of Dust and Water into a Membrane Switch《灰尘和水对膜片开关浸入程度的标准指南》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2865 13Standard Guide forClassifying the Degrees of Ingress of Dust and Water into aMembrane Switch1This standard is issued under the fixed designation F2865; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year o
2、f last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide establishes a classification system and refer-ences test methods for verifying the degrees of:1.1.1 The i
3、ngress of dust into the internal layers of amembrane switch.1.1.2 Ingress of water into the internal layers of a membraneswitch.1.1.3 Where external test methods are referenced, this guidespecifies the special conditions that shall be considered inapplying these tests to membrane switches and how th
4、e resultsare interpreted.1.2 This guide references test methods that can be used toestablish the ingress classification of a membrane switch.1.3 This guide utilizes the test methods and reportingstructure of IEC 60529 (Degrees of Protection Provided byEnclosures) modified for membrane switches.2. Re
5、ferenced Documents2.1 ASTM Standards:2F1578 Test Method for Contact Closure Cycling of a Mem-brane SwitchF1595 Practice for Viewing Conditions for Visual Inspectionof Membrane SwitchesF1680 Test Method for Determining Circuit Resistance of aMembrane SwitchF1689 Test Method for Determining the Insula
6、tion Resis-tance of a Membrane SwitchF2592 Test Method for Measuring the Force-Displacementof a Membrane Switch2.2 IEC Standard:360529 Degrees of Protection Provided by Enclosures3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 membrane switch, na momentary switching devicein w
7、hich at least one contact is on, or made of, a flexiblesubstrate.4. Classification System4.1 The ingress classification of a membrane switch isdesignated by the MSIP code:4.1.1 MSIP 6 5 A4.1.1.1 MSIP = Membrane Switch Ingress classification.4.1.1.2 1st Numeral = Dust Protection Code (see Table 1).4.
8、1.1.3 2nd Numeral = Water (Liquid) Protection Code (seeTable 2).4.1.1.4 A = If “A” is present then method or media deviatesfrom this guide and is reported.4.1.2 The MSIP code comprises a series of numerals. Eachnumeral represents the level of ingress offered by the mem-brane switch to each contamina
9、nt. In this guide when address-ing only the 1st or 2nd numeral the other numeral is replacedwith an “X” for clarity. For example, MSIP X5 refers only totesting for water ingression. The “X” notation is not used as afinal designation. If testing is not completeda“0”isused forthat numeral (see Table 1
10、 and Table 2).4.1.3 The numeric designations for dust and water are basedon those classified under IEC 60529.5. Significance and Use5.1 Ingression protection classifications are widely used bymanufacturers for specifying the level of protection offered byenclosures.5.2 An example of such a classific
11、ation scheme is IEC60529. Membrane switch manufacturers are often asked tomeet these standards, however the test methods specifiedwithin these standards do not address considerations specific tomembrane switches.5.3 The MSIP classification system considers the membraneswitch separately from the test
12、ing and IP codes used forclassifying the enclosure when subject to similar test condi-tions.1This guide is under the jurisdiction of ASTM Committee F01 on Electronicsand is the direct responsibility of Subcommittee F01.18 on Membrane Switches.Current edition approved Jan. 1, 2013. Published January
13、2013. Originallyapproved in 2011. Last previous edition approved in 2011 as F2865-11. DOI:10.1520/F2865-13.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the stand
14、ards Document Summary page onthe ASTM website.3Available from International Electrotechnical Commission (IEC), 3, rue deVaremb, P.O. Box 131, CH-1211 Geneva 20, Switzerland, http:/www.iec.ch.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United St
15、ates15.4 Ingression testing can be useful to identify designdeficiencies.6. Interferences6.1 The membrane switch shall be tested in a mounted statespecified in this guide because this is a classification of themembrane switch only without consideration of the enclosure.6.2 The length of time between
16、 the manufacture of themembrane switch and the performance of the test.6.3 The temperature at which the test is being conducted.7. Conditioning7.1 Unless otherwise specified in a relevant productstandard, the test samples for each test shall be in a clean andnew condition, and mounted to the testing
17、 backer for 24 h.7.2 The testing backer must be a rigid transparent backer tobetter observe the ingression of dust or water into the switch.Testing backer with geometries other than flat shall be re-ported.8. Test Method for Ingress of Dust into a MembraneSwitch8.1 Apparatus:8.1.1 Dust Chamber: Refe
18、rence IEC 60529 Section 13.4.8.1.2 Dust Media:8.1.2.1 For MSIP5X and MSIP6X : Reference IEC 60529Section 13.4.8.1.2.2 MSIP5XA and MSIP6XA: Media to be specified.8.1.2.3 Mounting SurfaceThe testing backer must be rigidand transparent and compatible with the mounting adhesive.Testing backer with geome
19、tries other than flat shall be re-ported.8.2 Pre-Test Setup:8.2.1 Measurements and Process Testing should be con-ducted on switches nearest the weakest point for ingress ofdust, such as the first switch cavity adjacent to an external ventchannel.8.2.2 Measure the circuit resistance per Test Method F
20、1680.8.2.3 Measure the insulation resistance per Test MethodF1680.8.2.4 For additional setup requirement see IEC 60529 Sec-tion 13.4.8.2.5 Perform visual inspection per Practice F1595 andestablish visual baseline to establish pre-test condition.8.3 In Process Test:8.3.1 For ingress of dust, numerals
21、 5 and 6, the test iscarried out according to Category 2 (testing at atmosphericpressure) per IEC 60529 Section 13.4.TABLE 1 1st Numeral = Dust Protection CodeNumerals or Letters Degree of Ingress Requirement Summary Test Equipment0 Not tested or no ingressprevention demonstratednone N/A1,2,3,4ANot
22、applicable to membraneswitchesnone N/A5 Dust protected Ingress of dust is not totally prevented.The switch operates as declared andthe post-test circuit resistance change isless than +30 % of pre-test, and belowthe maximum circuit resistance asspecified by the manufacturer.IEC 60529 Dust ChamberCate
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF28652013STANDARDGUIDEFORCLASSIFYINGTHEDEGREESOFINGRESSOFDUSTANDWATERINTOAMEMBRANESWITCH 灰尘 膜片 开关

链接地址:http://www.mydoc123.com/p-539620.html