《ASTM F2865-2011 Standard Guide for Classifying the Degrees of Ingression Protection Provided by a Membrane Switch《对薄膜开关的进入保护程度进行分类的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2865-2011 Standard Guide for Classifying the Degrees of Ingression Protection Provided by a Membrane Switch《对薄膜开关的进入保护程度进行分类的标准指南》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2865 11Standard Guide forClassifying the Degrees of Ingression Protection Providedby a Membrane Switch1This standard is issued under the fixed designation F2865; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide establishes a classification system and refer-ences test methods for verifying the degrees of protecti
3、onprovided by a membrane switch against the following:1.1.1 The ingress of dust into a membrane switch.1.1.2 Ingress of water into a membrane switch, or the entryinto the finished product on which it is mounted.1.1.3 It can be expanded to incorporate the degrees ofprotection from other environmental
4、 contaminants (such as saltfog) as these tests are developed either by ASTM, or existingtest methods developed by other organizations are determinedto be appropriate.1.1.4 Where external test methods are referenced, this guidespecifies the special conditions that shall be considered inapplying these
5、 tests to membrane switches and how the resultsare interpreted.1.1.5 The IP rating is based on the switch construction onlyand does not consider the effects of the switch body as a sealantfor the enclosure.1.1.6 For ingress of dust, numerals 5 and 6, the test iscarried out according to category 2 (t
6、esting at atmosphericpressure).1.2 This guide references appropriate test methods forverifying that a membrane switch satisfies the level of protec-tion specified by a given classification.1.3 This guide is a modification of the classification systemdescribed within IEC 60529 Degrees of Protection O
7、fferedBy An Electronic Enclosure.2. Referenced Documents2.1 ASTM Standards:2F1578 Test Method for Contact Closure Cycling of aMembrane SwitchF1680 Test Method for Determining Circuit Resistance of aMembrane SwitchF1689 Test Method for Determining the Insulation Resis-tance of a Membrane SwitchF2592
8、Test Method for Measuring the Force-Displacementof a Membrane Switch2.2 IEC Standard:360529 Degrees of Protection Offered by an ElectronicEnclosure3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 membrane switch, na momentary switching devicein which at least one contact is on,
9、 or made of, a flexiblesubstrate.4. Classification System4.1 The degree of protection provided by a membraneswitch is designated by the MS-IP code:4.1.1 MSAIP654.1.1.1 MS = membrane switch.4.1.1.2 A = If “A” is present in code then method or mediadeviates from this standard.4.1.1.3 IP = Standard Ing
10、ress Protection designation.4.1.1.4 1st Numeral = Dust Protection Code (see Table 1).4.1.1.5 2nd Numeral = Water (Liquid) Protection Code (seeTable 2).4.1.2 The MSIP code comprises a series of numerals. Eachnumeral represents the level of ingress protection offered bythe membrane switch to each cont
11、aminant. In this standardwhen addressing only the 1st or 2nd numeral the other numeralis replaced with an “X” for clarity. For example, MSIP X5would refer only to testing for water ingression. The “X”notation is not used as a final designation. If testing is notcompleteda“0”isused for that numeral (
12、see Table 1 andTable 2).4.1.3 It is intended that the classification scheme be ex-panded by the addition of further numerals to the sequence toincorporate tests for other contaminants. Deviation from thestandard are declared.4.1.4 The numeric designations for dust and water are basedon those classif
13、ied under IEC 60529.1This guide is under the jurisdiction of ASTM Committee F01 on Electronicsand is the direct responsibility of Subcommittee F01.18 on Membrane Switches.Current edition approved July 1, 2011. Published August 2011. DOI: 10.1520/F2865-11.2For referenced ASTM standards, visit the AST
14、M website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from International Electrotechnical Commission (IEC), 3, rue deVaremb, P.O. Box 131, CH-1211 Ge
15、neva 20, Switzerland, http:/www.iec.ch.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Significance and Use5.1 Ingression protection classifications are widely used bymanufacturers for specifying the level of protection offered by
16、electronic enclosures.5.2 An example of such a classification scheme is IEC60529. Membrane switch manufacturers are often asked tomeet these standards, however the test methods specifiedwithin these standards do not address considerations specific tomembrane switches.5.3 A single classification sche
17、me such as this is an impor-tant means of integrating the various standards that relate toingression protection specifically for membrane switches.5.4 Ingression testing can be useful to identify designdeficiencies.6. Interferences6.1 The membrane switch should not be tested in itsun-mounted state.
18、The switch sample or a representativecoupon of the switch should be mounted onto the final end-useenclosure, panel, bezel, or agreed upon material.6.1.1 Discussion Assembly Specimen ThisASTM test istrying to provide a practical world analog for the results hereinobtained, as a result, the unit under
19、 test (UUT) must be in thefinal mounted condition. The test is able to show flame-resistance in the final assembly as it interacts with themembrane switchs construction.6.2 The roughness, flatness, and existence of residues on thesubstrate surface to which the membrane switch is mounted.6.3 The leng
20、th of time between the lamination of themembrane switch layers together to make the switch.6.4 The length of time between the lamination of themembrane switch to the substrate and the performance on thetest.6.5 The temperature at which the test is being conducted.7. Conditioning7.1 Unless otherwise
21、specified in a relevant product stan-dard, the test samples for each test shall be in a clean and newcondition.7.2 It is preferred that the switch is mounted on a rigidtransparent backer to better observe the ingression of dust orwater into the switch, however when required and declared, theparts sh
22、all be mounted on the enclosure in the manner stated bythe manufacturer.8. Test Method for Ingress of Dust into a MembraneSwitch8.1 Apparatus:8.1.1 Dust Chamber: Reference IEC 60529 Section 13.4.8.1.2 Dust Media:8.1.2.1 For MSIP5X and MSIP6X : Reference IEC 60529Section 13.4.8.1.2.2 For all MSAIP5X
23、and MSAIP6X media to bespecified.8.1.3 Mounting SurfaceThe mounting surface shall bedeclared as the material, surface and any irregularities in theflat surface.8.1.4 EnclosureIf the switch and end product enclosureare tested together to demonstrate the switches ability to seal anopening then the fol
24、lowing must be followed: The mountingTABLE 1 1st Numeral = Dust Protection CodeNumerals or Letters Meaning for the protection of Requirement Summary Test Equipment0 Not tested/or no protection none N/A1,2,3 Not applicable to membrane switches none N/A4 Solid objects (no venting to thelocations outsi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF28652011STANDARDGUIDEFORCLASSIFYINGTHEDEGREESOFINGRESSIONPROTECTIONPROVIDEDBYAMEMBRANESWITCH 薄膜开关

链接地址:http://www.mydoc123.com/p-539619.html