ASTM F2625-2010 Standard Test Method for Measurement of Enthalpy of Fusion Percent Crystallinity and Melting Point of Ultra-High-Molecular Weight Polyethylene by Means of Different.pdf
《ASTM F2625-2010 Standard Test Method for Measurement of Enthalpy of Fusion Percent Crystallinity and Melting Point of Ultra-High-Molecular Weight Polyethylene by Means of Different.pdf》由会员分享,可在线阅读,更多相关《ASTM F2625-2010 Standard Test Method for Measurement of Enthalpy of Fusion Percent Crystallinity and Melting Point of Ultra-High-Molecular Weight Polyethylene by Means of Different.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2625 10Standard Test Method forMeasurement of Enthalpy of Fusion, Percent Crystallinity,and Melting Point of Ultra-High-Molecular WeightPolyethylene by Means of Differential Scanning Calorimetry1This standard is issued under the fixed designation F2625; the number immediately following
2、 the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method disc
3、usses the measurement of the heatof fusion and the melting point of ultra-high-molecular weightpolyethylene (UHMWPE), and the subsequent calculation ofthe percentage of crystallinity.1.2 This test method can be used for UHMWPE in powderform, consolidated form, finished product, or a used product. It
4、can also be used for irradiated or chemically-crosslinkedUHMWPE.1.3 This test method does not suggest a desired range ofcrystallinity or melting points for specific applications.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandar
5、d.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced
6、 Documents2.1 ASTM Standards:2D3418 Test Method for Transition Temperatures and En-thalpies of Fusion and Crystallization of Polymers byDifferential Scanning CalorimetryE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodE793 Test Method for Enthalpies of
7、Fusion and Crystalli-zation by Differential Scanning CalorimetryE967 Test Method for Temperature Calibration of Differen-tial Scanning Calorimeters and Differential Thermal Ana-lyzersE968 Practice for Heat Flow Calibration of DifferentialScanning CalorimetersE1953 Practice for Description of Thermal
8、 Analysis andRheology Apparatus3. Terminology3.1 Symbols:3.1.1 DHf, ntheoretical heat of fusion of 100 % crystallinematerial (J/g).3.1.2 DHs, nmass normalized heat of fusion of the testsample (J/g).3.1.3 Tp, nmelting temperature at the peak of the meltingendotherm (C).3.1.4 To, nonset temperature of
9、 the melting endotherm(C).3.1.5 %X, npercentage of crystallinity of material.4. Summary of Test Method4.1 This test method consists of placing a known mass ofUHMWPE in a sample pan and heating the sample pan at acontrolled temperature while measuring the heat flow to thesample pan and an empty refer
10、ence pan. The area under themelting endotherm, indicative of the enthalpy of melting, isnormalized with the sample mass. This value is then normal-ized with the theoretical enthalpy of melting of 100 % crystal-line polyethylene to determine the percentage of crystallinity inthe test sample.5. Signif
11、icance and Use5.1 The crystallinity of UHMWPE will influence its me-chanical properties, such as creep and stiffness. The reportedcrystallinity will depend on the integration range used to1This test method is under the jurisdiction of ASTM Committee F04 on Medicaland Surgical Materials and Devices a
12、nd is the direct responsibility of SubcommitteeF04.15 on Material Test Methods.Current edition approved Dec. 1, 2010. Published December 2010. Originallyapproved in 2007. Last previous edition approved in 2007 as F2625 07. DOI:10.1520/F2625-10.2For referenced ASTM standards, visit the ASTM website,
13、www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.de
14、termine the heat of fusion, and the theoretical heat of fusionof 100 % crystalline polyethylene used to calculate the percentcrystallinity in an unknown specimen. Differential scanningcalorimetry is an effective means of accurately measuring bothheat of fusion and melting temperature.5.2 This test m
15、ethod is useful for both process control andresearch.6. Interferences6.1 As machining processes can affect the crystalline struc-ture of UHMWPE, care should be taken to obtain a represen-tative sample away from the surface of a component if bulkmeasurements are desired.6.2 The integration range used
16、 to measure the area of themelting endotherm will affect the measured value, as canheating rate. Therefore, the same ranges and test conditionsmust be used to ensure comparative results between laborato-ries.6.3 The sample must not be too tall, as temperature gradi-ents can then be generated in the
17、sample, leading to erroneousresults. It is suggested that the sample height should be lessthan 2 mm.7. Apparatus7.1 Differential scanning calorimeter (DSC), as described inTest Method D3418 and Practice E1953.7.2 Aluminum DSC sample pans, crimpable. Pans withventing holes are optional. The same type
18、 of pan must be usedfor the sample and reference pan.7.3 Analytical balance, accurate to 60.01 mg.NOTE 1According to Test Method E793, the repeatability standarddeviation for the enthalpy of fusion of a polyolefin is 1.2 % when using abalance resolution of 0.01 mg.8. Sampling, Test Specimens, and Te
19、st Units8.1 The UHMWPE test specimen can be in the form ofpowder, flake, film, or pellet.8.2 If a specimen is to be cut from a larger piece ofpolyethylene, it is recommended that a clean, sharp razor bladeor other equivalent tool is used to cut a slice. The specimenmust not be cut with a tool that g
20、enerates enough heat to meltthe UHMWPE. A core borer or punch can also be used to cuta sample from a film of UHMWPE.8.3 The specimen should be fairly flat to ensure goodthermal contact with the sample pan.8.4 It is recommended that a minimum of three specimensper test location are tested.NOTE 2“Test
21、 location” is defined as the location on the sample wherethe DSC analysis is performed.9. Preparation of Apparatus9.1 The DSC test chamber should be purged with drynitrogen, argon, or helium at a controlled flow rate during alltests. The same rate and gas should be used for all calibrationsand tests
22、. A purge rate of 10 to 50 ml/min is recommended.10. Calibration and Standardization10.1 Calibrate the temperature and heat flow signals of theDSC according to Test Method E967 and Practice E968,respectively. Typically, pure indium is used as a referencematerial. Both onset of the melting endotherm
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF26252010STANDARDTESTMETHODFORMEASUREMENTOFENTHALPYOFFUSIONPERCENTCRYSTALLINITYANDMELTINGPOINTOFULTRAHIGHMOLECULARWEIGHTPOLYETHYLENEBYMEANSOFDIFFERENTPDF

链接地址:http://www.mydoc123.com/p-539130.html