《ASTM F2625-2007 Standard Test Method for Measurement of Enthalpy of Fusion Percent Crystallinity and Melting Point of Ultra-High-Molecular Weight Polyethylene by Means of Different.pdf》由会员分享,可在线阅读,更多相关《ASTM F2625-2007 Standard Test Method for Measurement of Enthalpy of Fusion Percent Crystallinity and Melting Point of Ultra-High-Molecular Weight Polyethylene by Means of Different.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2625 07Standard Test Method forMeasurement of Enthalpy of Fusion, Percent Crystallinity,and Melting Point of Ultra-High-Molecular WeightPolyethylene by Means of Differential Scanning Calorimetry1This standard is issued under the fixed designation F 2625; the number immediately followi
2、ng the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method d
3、iscusses the measurement of the heatof fusion and the melting point of ultra-high-molecular weightpolyethylene (UHMWPE), and the subsequent calculation ofthe percentage of crystallinity.1.2 This test method can be used for UHMWPE in powderform, consolidated form, finished product, or a used product.
4、 Itcan also be used for irradiated or chemically-crosslinkedUHMWPE.1.3 This test method does not suggest a desired range ofcrystallinity or melting points for specific applications.1.4 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informatio
5、nonly.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Refere
6、nced Documents2.1 ASTM Standards:2D 3418 Test Method for Transition Temperatures of Poly-mers By Differential Scanning CalorimetryE 793 Test Method for Enthalpies of Fusion and Crystalli-zation by Differential Scanning CalorimetryE 967 Test Method for Temperature Calibration of Differ-ential Scannin
7、g Calorimeters and Differential ThermalAnalyzersE 968 Practice for Heat Flow Calibration of DifferentialScanning CalorimetersE 1953 Practice for Description of Thermal Analysis andRheology Apparatus3. Terminology3.1 Symbols:3.1.1 DHf, ntheoretical heat of fusion of 100 % crystallinematerial (J/g).3.
8、1.2 DHs, nmass normalized heat of fusion of the testsample (J/g).3.1.3 Tp, nmelting temperature at the peak of the meltingendotherm (C).3.1.4 To, nonset temperature of the melting endotherm(C).3.1.5 %X, npercentage of crystallinity of material.4. Summary of Test Method4.1 This test method consists o
9、f placing a known mass ofUHMWPE in a sample pan and heating the sample pan at acontrolled temperature while measuring the heat flow to thesample pan and an empty reference pan. The area under themelting endotherm, indicative of the enthalpy of melting, isnormalized with the sample mass. This value i
10、s then normal-ized with the theoretical enthalpy of melting of 100 % crystal-line polyethylene to determine the percentage of crystallinity inthe test sample.5. Significance and Use5.1 The crystallinity of UHMWPE will influence its me-chanical properties, such as creep and stiffness. The reportedcry
11、stallinity will depend on the integration range used todetermine the heat of fusion, and the theoretical heat of fusionof 100 % crystalline polyethylene used to calculate the percent1This test method is under the jurisdiction of ASTM Committee F04 on Medicaland Surgical Materials and Devices and is
12、the direct responsibility of SubcommitteeF04.15 on Material Test Methods.Current edition approved Feb. 1, 2007. Published February 2007.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume in
13、formation, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.crystallinity in an unknown specimen. Differential scanningcalorimetry is an effective means of accurately mea
14、suring bothheat of fusion and melting temperature.5.2 This test method is useful for both process control andresearch.6. Interferences6.1 As machining processes can affect the crystalline struc-ture of UHMWPE, care should be taken to obtain a represen-tative sample away from the surface of a compone
15、nt if bulkmeasurements are desired.6.2 The integration range used to measure the area of themelting endotherm will affect the measured value, as canheating rate. Therefore, the same ranges and test conditionsmust be used to ensure comparative results between laborato-ries.6.3 The sample must not be
16、too tall, as temperature gradi-ents can then be generated in the sample, leading to erroneousresults. It is suggested that the sample height should be lessthan 2 mm.7. Apparatus7.1 Differential scanning calorimeter (DSC), as described inTest Method D 3418 and Practice E 1953.7.2 Aluminum DSC sample
17、pans, crimpable. Pans withventing holes are optional. The same type of pan must be usedfor the sample and reference pan.7.3 Analytical balance, accurate to 60.01 mg.NOTE 1According to Test Method E 793, the repeatability standarddeviation for the enthalpy of fusion of a polyolefin is 1.2 % when usin
18、g abalance resolution of 0.01 mg.8. Sampling, Test Specimens, and Test Units8.1 The UHMWPE test specimen can be in the form ofpowder, flake, film, or pellet.8.2 If a specimen is to be cut from a larger piece ofpolyethylene, it is recommended that a clean, sharp razor bladeor other equivalent tool is
19、 used to cut a slice. The specimenmust not be cut with a tool that generates enough heat to meltthe UHMWPE. A core borer or punch can also be used to cuta sample from a film of UHMWPE.8.3 The specimen should be fairly flat to ensure goodthermal contact with the sample pan.8.4 It is recommended that
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF26252007STANDARDTESTMETHODFORMEASUREMENTOFENTHALPYOFFUSIONPERCENTCRYSTALLINITYANDMELTINGPOINTOFULTRAHIGHMOLECULARWEIGHTPOLYETHYLENEBYMEANSOFDIFFERENTPDF

链接地址:http://www.mydoc123.com/p-539129.html