ASTM F2592-2009 Standard Test Method for Measuring the Force-Displacement of a Membrane Switch《测量薄膜开关的力位移的标准试验方法》.pdf
《ASTM F2592-2009 Standard Test Method for Measuring the Force-Displacement of a Membrane Switch《测量薄膜开关的力位移的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2592-2009 Standard Test Method for Measuring the Force-Displacement of a Membrane Switch《测量薄膜开关的力位移的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2592 09Standard Test Method forMeasuring the Force-Displacement of a Membrane Switch1This standard is issued under the fixed designation F 2592; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of forcedisplacement characteristics of a membrane switch.1.1.1 This test method replaces
3、 Test Method F 1570 (TactileRatio). Tactile Response Slope better represents the character-ization of tactile sensation, previously called “Tactile Ratio” inTest Method F 1570.1.1.2 This test method replaces Test Method F 1682(Travel).1.1.3 This test method replaces Test Method F 1597 (Ac-tuation an
4、d Contact Force).1.1.4 This test method replaces Test Method F 1997 (SwitchSensitivity).1.2 Force displacement hysterisis loop curve can be used inthe determination of Actuation Force, Displacement, ContactForce, Return Force, and Tactile Response Slope.1.3 This standard does not purport to address
5、all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Terminology2.1 Definitions:2.1.1 break displacement (Tb)th
6、e displacement at contactbreak.2.1.2 break force (Fb)the force at contact break.2.1.3 circuit resistanceelectrical resistance as measuredbetween two test points whose internal contacts, when heldclosed, complete a circuit.2.1.4 closure (make)the event at which a specified resis-tance is achieved.2.1
7、.5 contact breakpoint at which circuit resistance ishigher than specified resistance on return.2.1.6 contact displacement (Tc)the displacement at con-tact closure.2.1.7 contact force (Fc)the force at contact closure.2.1.8 displacementmeasured distance of movement whenmembrane is depressed.2.1.8.1 Di
8、scussionDisplacement is sometimes referred toas “switch travel.”2.1.9 Fmaxan applied force, maximum force measuredprior to or including point (Fmin) (see Fig. 1).2.1.9.1 DiscussionSometimes referred to as ActuationForce.2.1.10 Fminan applied force, minimum force seen be-tween Fmax and point at which
9、 probe movement ceases.2.1.10.1 DiscussionFmax can equal Fmin.2.1.11 force-displacement hysteresis curverelationshipbetween force applied and displacement of a membrane switchin terms of the actuation and return (recovery).2.1.11.1 DiscussionUsually expressed as a line graph;sometimes referred to as
10、 Force-Travel curve (see Fig. 1).2.1.12 membrane switcha momentary switching device inwhich at least one contact is on, or made of, a flexiblesubstrate.2.1.13 non-tactile switchswitch that does not have atactile response and therefore has a response slope equal tozero because Fmax and Fmin are the s
11、ame (see Fig. 2).2.1.14 return min force (Frmin)minimum force seenduring return cycle before reaching Frmax.2.1.15 return max force (Frmax)maximum force mea-sured during return cycle after achieving Frmin.2.1.16 specified resistancemaximum allowable resistanceas measured between two terminations who
12、se internal switchcontacts are held closed to complete a circuit.2.1.17 switch teasing (break)the displacement measure-ment on the force-displacement curve between contact break(Fb) and return force (Frmin).2.1.18 switch teasing (make)the displacement measure-ment on the force-displacement curve bet
13、ween contact force(Fc) and minimum force (Fmin).2.1.19 tactile recovery sloperate of change of return forcewith respect to displacement, as measured between TFrminand TFrmax (see Fig. 3).2.1.20 tactile responsea physical sensation, caused by asudden collapse or snapback, or both, of a membrane switc
14、h.2.1.21 tactile response sloperate of change of appliedforce with respect to displacement, as measured betweenTfmax and Tfmin (see Figs. 3 and 4).1This test method is under the jurisdiction of ASTM Committee F01 onElectronics and is the direct responsibility of Subcommittee F01.18 on MembraneSwitch
15、es.Current edition approved June 15, 2009. Published July 2009. Originallyapproved in 2006. Last previous edition approved in 2008 as F 2592-08.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.2.1.22 tactile switcha switch that has a
16、tactile responseand therefore has a response slope less than zero (negativeslope).2.1.23 TfmaxDisplacement at Fmax.2.1.24 TfminDisplacement at Fmin.2.1.25 Tfrmaxdisplacement at Frmax.2.1.26 Tfrmindisplacement at Frmin.3. Significance and Use3.1 The force and displacement values when converted to asl
17、ope are useful in quantifying the differences in tactileresponse among membrane switches.3.2 Specified resistance is useful to manufacturers and userswhen designing membrane switch interface circuitry.3.3 Actuation force and contact force are useful to manu-facturers and users in determining the sui
18、tability, reference andaesthetics of a membrane switch in a given application.3.4 The tendency of a switch to make or break electricalcontact at unexpected moments during closure or release canbe a sign of a poor design. The degree of teasing can rangefrom a simple annoyance to a failure of critical
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF25922009STANDARDTESTMETHODFORMEASURINGTHEFORCEDISPLACEMENTOFAMEMBRANESWITCH 测量 薄膜开关 位移 标准 试验 方法

链接地址:http://www.mydoc123.com/p-539048.html