ASTM F2495-2005(2011) Standard Test Method for Determining Energy Consumption of MFDs with Copying Capability and Similar Office Imaging Equipment《测定有复印能力的多功能显示器和类似的办公成像设备能量消耗的标准试验.pdf
《ASTM F2495-2005(2011) Standard Test Method for Determining Energy Consumption of MFDs with Copying Capability and Similar Office Imaging Equipment《测定有复印能力的多功能显示器和类似的办公成像设备能量消耗的标准试验.pdf》由会员分享,可在线阅读,更多相关《ASTM F2495-2005(2011) Standard Test Method for Determining Energy Consumption of MFDs with Copying Capability and Similar Office Imaging Equipment《测定有复印能力的多功能显示器和类似的办公成像设备能量消耗的标准试验.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2495 05 (Reapproved 2011)Standard Test Method forDetermining Energy Consumption of MFDs with CopyingCapability and Similar Office Imaging Equipment1This standard is issued under the fixed designation F2495; the number immediately following the designation indicates the year oforiginal
2、adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This procedure provides a test method by which multi-functional devi
3、ces (MFDs) with electro-photographic copyingcapability and similar office imaging equipment may be ratedfor energy consumption.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish a
4、ppro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 International Standards:ISO/IEC 11159 Minimum Information to be Included inSpecification SheetsCopying Machines2ISO 554 Standard Atmospheres for Conditioning and
5、/orTesting Specifications22.2 Federal Energy Management Program (FEMP) web-site:http:/www.eere.energy.gov/femp/technologies/eep_standby_power.cfm#sleep3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 optional devicesany device added to improve thefunctionality of the base unit.
6、 They include an automaticdocument feeder (ADF), sorter, finisher and expansionmemory.3.1.2 copier speed, first copy (X)one of the convenientlevels for which the machines speed is measured. This iscalculated based on the amount of time, a1(sec), counted in anormal operating mode from the beginning o
7、f pressing theprint button of the machine to the end of ejecting the first copy,X = 60/ a1(ipm). For MFDs with ADF, the amount of time, a1shall be used, counted from pressing the print button afterplacing an original or originals on the ADF to the end ofejecting the first copy.3.1.3 copier speed, mu
8、lti copy (Y)one of the convenientlevels for which the machines speed is measured. This iscalculated based on the amount of time, a2(sec), counted in anormal operating mode from the end of ejecting the first copyafter pressing the print button of the machine to the end ofejecting the remaining copies
9、 (b), Y =(b) 60/a2(ipm).Normally, the value declared in the machines specificationsshall be used.3.1.4 ready modethe condition that exists when the ma-chine is ready for copying, but has not yet started copying, andhas not entered an energy-saver mode, either.3.1.5 copying cyclethe condition that ex
10、ists from thebeginning to the end of a nominal job cycle (1 h) to produce acopy or copies. According to the machines multi copy speed(Y) declared in the specifications, the following are listed in JobTables: nominal monthly volumes assumed, nominal volumesper day and combinations of the number of jo
11、bs as18 day (1 h)nominal jobs, the number of originals per job and the numberof copies per original.3.1.6 copying energythe amount of energy needed inexcess of ready mode energy during a copying cycle.3.1.7 copying timethe amount of time that the nominaljobs are run when testing copying energy durin
12、g a copyingcycle.3.1.8 wake-up energythe amount of energy needed inexcess of ready mode energy when the machine recovers froma standard work days first sleep stand-by mode.3.1.9 energy-saver modethe condition that exists when themachine is not making copies and is consuming less powerthan when the m
13、achine is in a ready mode. The machine goesinto this mode after it completes a job such as copying and nojob is scheduled in a specified time period. Since the Interna-tional Energy Star Program has been used widely in the world,this has caused MFDs to have this mode. This standardparticularly desig
14、nates this condition as an energy-saver modein operating hours (9 h) of a standard work day.3.1.9.1 DiscussionThe International Energy Star Programstipulates that the machine shall be set to enter an energy-saver1This test method is under the jurisdiction ofASTM Committee F05 on BusinessImaging Prod
15、ucts and is the direct responsibility of Subcommittee F05.04 onElectrostatic Imaging Products.Current edition approved Oct. 1, 2011. Published September 2012. Originallyapproved in 2005. Last previous edition approved in 2005 as F249505. DOI:10.1520/F2495-05R11.2Available from American National Stan
16、dards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1mode 15 minutes or less after the end of a job such as copying.However, on the assumption that the machine is used in
17、 anetworked environment, considering the fact that shorter pass-ing time has been set than before because a recovery triggereasily takes place and recovery time tends to be reduced, thistest method stipulates that the machine shall stay in a readymode for 10 minutes after the end of a job such as co
18、pying upuntil it starts passing to the energy-saver mode. The recoverytime from the energy-saver mode to the ready mode shall be setto 30 seconds or less. Energy-saver mode design to fulfill thisrecovery time is left to the manufacturers discretion. This testmethod provides energy calculations on th
19、e assumption that thepassing time is 10 minutes. If setting of the time shorter than 10minutes is accepted by users in the future, the procedure of thistest method will be reviewed.3.1.10 sleep stand-by modethe condition with less energyconsumption than the energy-saver mode in 3.1.9. The machineent
20、ers the energy-saver mode 10 minutes after the end of a jobsuch as copying and then enters a sleep stand-by mode, if noadditional job is scheduled in a specified time period.Normally, this sleep stand-by mode stays for a whole day ofSaturday and Sunday weekends other than standard work days.As for s
21、tandard work days, the machine stays in this mode atnight as a night stand-by condition. It is calculated by subtract-ing the 9 hours of operation from the 24 hours in a day.3.1.11 energy-saver recovery timethe amount of time thatthe machine takes to enter the ready mode after it comes out ofthe ene
22、rgy-saver mode in the 9-h operating condition of astandard work day.3.1.12 energy-saver mode timethe amount of time that themachine is in an energy-saver mode in the 9-hour operatingcondition of a standard work day.3.1.13 lunch breakone hour assigned to a lunch break thatexists between 4-h morning a
23、nd 4-h afternoon in the 9-hoperating condition of a standard work day. The machine staysin an energy-saver mode during this time period.3.1.14 jobmaking a copy or copies from one or moreoriginals without interruption or delay between originals. Sincetarget machines are MFDs with copying capability,
24、copyingshall be used for rating to represent all the jobs.3.1.15 machine energythe energy obtained by subtractingenergy consumed for copying (3.1.6) from total energy con-sumed in a standard month where the machine is plugged-in 24h/day including the 9-h operating condition.3.1.16 nominal copies per
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF249520052011STANDARDTESTMETHODFORDETERMININGENERGYCONSUMPTIONOFMFDSWITHCOPYINGCAPABILITYANDSIMILAROFFICEIMAGINGEQUIPMENT

链接地址:http://www.mydoc123.com/p-538849.html