《ASTM F2387-2004(2012) Standard Specification for Manufactured Safety Vacuum Release Systems (SVRS) for Swimming Pools Spas and Hot Tubs《游泳池 温泉和热浴盆的人造安全真空释放系统 (SVRS) 的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2387-2004(2012) Standard Specification for Manufactured Safety Vacuum Release Systems (SVRS) for Swimming Pools Spas and Hot Tubs《游泳池 温泉和热浴盆的人造安全真空释放系统 (SVRS) 的标准规范》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2387 04 (Reapproved 2012)Standard Specification forManufactured Safety Vacuum Release Systems (SVRS) forSwimming Pools, Spas and Hot Tubs1This standard is issued under the fixed designation F2387; the number immediately following the designation indicates the year oforiginal adoption o
2、r, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.INTRODUCTIONThe U.S. Consumer Product Safety Commission is aware of 138 swimming pool and
3、spa drainsuction entrapments between 1985 and 2001. During this time, 35 deaths due to drain suctionentrapment have been confirmed, including 15 deaths due to hair entrapment, 15 deaths due to bodyentrapment and five deaths due to entrapment of an unknown type.With the understanding of the potential
4、 hazard and despite the lack of extensive epidemiologicaldata, the manufacturers, consumers, and users supported by CPSC staff decided on February 6, 2001to proceed with dedicated time, expense, and effort toward development of a voluntary safety standardto reduce the possibilities of injuries due t
5、o swimming pool, spa, and hot tub body and limbentrapment.If a cover or grate is unfastened, missing or broken, exposure to the drain suction force couldproduce evisceration. Even though it is expected that safety vacuum release devices may help inreducing cases of evisceration, the devices are not
6、designed for nor intended to do so. More directefforts are related to the use of proper drain covers, 12 by 12 in. or larger drain covers, pool covers,and so forth. “Layered protection” should be used as outlined in CPSCs “Guidelines for AddressingPotential Entrapment Hazards Associated with Swimmin
7、g Pools and Spas.”This specification is not intended to and does not address hair entrapment.Field fabricated vent pipes are excluded from this specification and will be addressed in a separatestandard under development.1. Scope1.1 This specification covers requirements for safetyvacuum release syst
8、ems (SVRS) for use on swimming pools,spas, hot tubs, and wading pools.1.2 This specification is intended to reduce the risk ofdrowning or entrapment by providing a rapid detection andrapid release of vacuum or preventing a dangerous vacuumaltogether when a person becomes entrapped at the suctionoutl
9、et serving a pumping system.1.3 The values stated in customary English units are to beregarded as the standard. Any values in parentheses are givenfor information only.1.4 The following safety hazards caveat pertains only to thetest methods section, Section 5, of this specification. Thisstandard doe
10、s not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standa
11、rds:2D2466 Specification for Poly(Vinyl Chloride) (PVC) PlasticPipe Fittings, Schedule 40D2468 Specification for Acrylonitrile-Butadiene-Styrene(ABS) Plastic Pipe Fittings, Schedule 403D2855 Practice for Making Solvent-Cemented Joints withPoly(Vinyl Chloride) (PVC) Pipe and FittingsF402 Practice for
12、 Safe Handling of Solvent Cements, Prim-ers, and Cleaners Used for Joining Thermoplastic Pipe andFittings1This specification is under the jurisdiction of ASTM Committee F15 onConsumer Products and is the direct responsibility of Subcommittee F15.51 onSafety Vacuum Release Systems for Swimming Pools,
13、 Spas and Hot Tubs.Current edition approved Aug. 1, 2012. Published August 2012. Originallyapproved in 2003. Last previous edition approved in 2004 as F2387 04. DOI:10.1520/F2387-04R12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceast
14、m.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohoc
15、ken, PA 19428-2959, United States.2.2 ASME Standard:4ANSI/ASME B1.20.1 Pipe Threads, General Purpose, Inch2.3 Federal Document:5CPSC Document Guidelines for Addressing Potential En-trapment Hazards Associated with Swimming Pools andSpas2.4 NSF Document:6NSF 50 Circulatory System Components and Relat
16、ed Ma-terials for Swimming Pools, Spas, Hot Tubs72.5 UL Standards:8UL 1081 Standard for Safety for Swimming Pool Pumps,Filters and ChlorinatorsUL 746A Plastics Testing3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 high vacuum occurrenceevent where the operatingvacuum normally
17、 present within a pool circulation systemsuddenly increases due to a suction outlet blockage.3.1.2 interrupter element (IE)pad or mat used to simulatean entrapment event by blocking the suction outlet completely.3.1.3 non-mechanical SVRSSVRS with no moving parts.3.1.4 readily affxedto be easily retr
18、ofitted to existingsystems where an entrapment hazard is possible using ap-proved pipe fittings or approved adapters, or both.3.1.5 return inletappurtenance for conveying water re-turned to the pool.3.1.6 safety vacuum release system (SVRS)system ordevice capable of providing vacuum release at a suc
19、tion outletcaused by a high vacuum occurrence due to a suction outletblockage. SVRS devices must allow for the vacuum releasewith or without suction outlet cover(s) in place, and shalloperate in such a way as to not defeat or disengage other layersof protection installed to protect against suction e
20、ntrapment.3.1.7 suction outletappurtenance for conveying water outof a pool, spa, hot tub, whirlpool, therapy unit or similarfixture.3.1.8 test actuator (TA)device used to lower the inter-rupter element (IE) in a uniform manner and rate.4. Requirements4.1 General:4.1.1 Exposed surfaces shall be free
21、 from rough or sharpedges.4.1.2 An SVRS shall not be made dysfunctional without theuse of tools.4.1.3 Manufacturers shall evaluate all materials for expo-sure and environmental conditions (chemicals, etc.) expectedto be encountered in the use condition over a period of time toinsure long term durabi
22、lity and operation. NSF 50 andUL 1081 may be used as guidelines.4.1.4 Materials exposed to outdoor elements shall be UVresistant and capable of withstanding ambient temperaturesbetween -40 and 140F (in accordance with 4.1.15 and 4.2.2).4.1.5 Under normal system operating conditions, the SVRSshall no
23、t adversely affect pump suction, system pressure,system flow, or other equipment performance.4.1.5.1 An SVRS must provide the means to protect thepump against consequential damage by a pump running drydue to a loss of prime.4.1.6 An SVRS shall latch or lock out in the open or off(safe) position foll
24、owing a high vacuum occurrence until reset.Systems such as non-mechanical SVRSs that have no movingparts do not require this latch or lock out feature.4.1.7 SVRSs, following a high vacuum occurrence, shall bemanually reset or automatically reset to its original safeposition without requiring special
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF238720042012STANDARDSPECIFICATIONFORMANUFACTUREDSAFETYVACUUMRELEASESYSTEMSSVRSFORSWIMMINGPOOLSSPASANDHOTTUBS

链接地址:http://www.mydoc123.com/p-538570.html