《ASTM F2384-2005 Standard Specification for Wrought Zirconium-2 5Niobium Alloy for Surgical Implant Applications (UNS R60901)《用于外科植入物的锻造锆-2 5铌合金的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2384-2005 Standard Specification for Wrought Zirconium-2 5Niobium Alloy for Surgical Implant Applications (UNS R60901)《用于外科植入物的锻造锆-2 5铌合金的标准规范》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2384 05Standard Specification forWrought Zirconium-2.5Niobium Alloy for Surgical ImplantApplications (UNS R60901)1This standard is issued under the fixed designation F 2384; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revi
2、sion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the chemical, mechanical, andmetallurgical requirements for wrought zirco
3、nium-2.5niobiumalloy to be used in the manufacture of surgical implants (1).21.2 The values stated in inch-pound units are to be regardedas the standard. The SI equivalents in parentheses may beapproximate.2. Referenced Documents2.1 ASTM Standards:3B 550/B 550M Specification for Zirconium and Zircon
4、iumAlloy Bar and WireE8 Test Methods for Tension Testing of Metallic MaterialsE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with SpecificationsE112 Test Methods for Determining Average Grain SizeE 1552 Test Method for Determining Hafnium in Zirco-nium and Zirconium A
5、lloys Using the D-C Argon PlasmaSpectrometerF67 Specification for Unalloyed Titanium for SurgicalImplant Applications (UNS R50250, UNS R50400, UNSR50550, UNS R50700)F 748 Practice for Selecting Generic Biological Test Meth-ods for Materials and Devices2.2 ISO Standard:4ISO 6829 Metallic Materials Te
6、nsile Testing at AmbientTemperature2.3 American Society for Quality Standard:5ASQ C1 Specification of General Requirements for a Qual-ity Program3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 annealed, adjmaterial that exhibits a recrystalizedgrain structure.3.1.2 lot, nthe t
7、otal number of mill products producedfrom the same melt heat under the same conditions at essen-tially the same time.4. Product Classification4.1 barrounds, flats or shapes from 0.1875 to 4 in. (4.76to 101.60 mm) in diameter or thickness (other sizes and shapesby special order).4.2 wirerounds or fla
8、ts less than 0.1875 in. (4.76 mm) indiameter or thickness.5. Ordering Information5.1 Include with inquiries and orders for material under thisspecification the following information:5.1.1 Quantity,5.1.2 ASTM designation and date of issue,5.1.3 Grade (if applicable),5.1.4 Form (bar, or wire),5.1.5 Co
9、ndition (see 6.3),5.1.6 Mechanical properties (if applicable for special con-ditions),5.1.7 Finish (see 6.2),5.1.8 Applicable dimension including size, thickness, width,or drawing number,5.1.9 Special tests, if any, and5.1.10 Other requirements.6. Materials and Manufacture6.1 Materials covered by th
10、is specification shall be pro-duced by multiple vacuum melting in arc furnaces, electronbeam melting, or other melting processes conventionally usedfor reactive metals.1This specification is under the jurisdiction of ASTM Committee F04 onMedical and Surgical Materials and Devices and is the direct r
11、esponsibility ofSubcommittee F04.12 on Metallurgical Materials.Current edition approved Jan. 1, 2005. Published January 2005.2The boldface numbers in parentheses refer to the list of references at the end ofthis standard.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact
12、 ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.5Available from American Society
13、for Quality (ASQ), 600 N. Plankinton Ave.,Milwaukee, WI 53203.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.2 FinishThe mill product may be furnished to theimplant manufacturer as descaled or pickled, abrasivelyblasted, chemicall
14、y milled, ground, machined, peeled, pol-ished, or as specified by the purchaser.6.3 ConditionBarstock shall be furnished in the annealedcondition unless otherwise specified.7. Chemical Requirements7.1 The heat analysis shall conform to the chemical com-position of Table 1. Ingot analysis may be used
15、 for reporting allchemical requirements, except hydrogen, oxygen, and nitro-gen. Samples for hydrogen, oxygen and nitrogen shall be takenfrom the finished mill product. The supplier shall not shipmaterial with chemistry outside the requirements specified inTable 1.7.1.1 Requirements for the major an
16、d minor elementalconstituents are listed in Table 1. Also listed are importantresidual elements. Analysis for elements not listed in Table 1 isnot required to verify compliance with this specification.7.2 Product Analysis:7.2.1 Product analysis tolerances do not broaden the speci-fied heat analysis
17、requirements but cover variations betweenlaboratories in the measurement of chemical content. Theproduct analysis tolerances shall conform to the producttolerances in Table 2.7.2.2 The product analysis is either for the purpose ofverifying the composition of a heat or manufacturing lot, or todetermi
18、ne variations in the composition within the heat.7.2.3 Acceptance or rejection of a heat or manufacturing lotof material may be made by the purchaser on the basis of thisproduct analysis.7.3 For referee purposes, use Test Method E 1552 or otheranalytical methods, or both, as agreed upon between thep
19、urchaser and the supplier.7.4 The samples for chemical analysis shall be representa-tive of the material being tested. The utmost care must be usedin sampling zirconium for chemical analysis because of itsaffinity for elements such as oxygen, nitrogen, and hydrogen.In cutting samples for analysis, t
20、herefore, the operation shouldbe carried out insofar as possible in a dust-free atmosphere.Cutting tools should be clean and sharp. Samples for analysisshould be stored in suitable containers.8. Mechanical Requirements8.1 The material supplied under this specification shallconform to the mechanical
21、property requirements in Table 3.8.2 Specimens for tension tests shall be machined from barin the longitudinal direction and tested in accordance with TestMethods E8. Tensile properties shall be determined using astrain rate of 0.003 to 0.007 in./in./min (mm/mm/min) throughyield and then the crosshe
22、ad speed may be increased so as toproduce fracture in approximately one additional minute.8.3 Number of TestsPerform a minimum of two tensiontests from each lot (see 3.1.2). Should either of the two testspecimens not meet the specified requirements, test two addi-tional test pieces representative of
23、 the same lot in the samemanner. The lot will be considered in compliance only if bothadditional test pieces meet the specified requirements.8.4 Tension test results for which any specimen fracturesoutside the gage length shall be considered acceptable, if boththe elongation and reduction of area me
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF23842005STANDARDSPECIFICATIONFORWROUGHTZIRCONIUM25NIOBIUMALLOYFORSURGICALIMPLANTAPPLICATIONSUNSR60901

链接地址:http://www.mydoc123.com/p-538563.html