ASTM F2343-2015 Standard Test Method for Livestock Meat and Poultry Evaluation Devices《牲畜 肉和禽类评价设备的标准试验方法》.pdf
《ASTM F2343-2015 Standard Test Method for Livestock Meat and Poultry Evaluation Devices《牲畜 肉和禽类评价设备的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2343-2015 Standard Test Method for Livestock Meat and Poultry Evaluation Devices《牲畜 肉和禽类评价设备的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2343 09F2343 15Standard Test Method forLivestock, Meat, and Poultry Evaluation Devices1This standard is issued under the fixed designation F2343; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revisi
2、on. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers test methods used to determine the accuracy of electronic devices that evaluate composition orquality con
3、stituents of livestock, meat, and poultry.1.2 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility
4、of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F2463 Terminology for Livestock, Meat, and Poultry Evaluation Systems2.2 NIST Standard:3NIST Handbook 44
5、Electronic Livestock, Meat, and Poultry Evaluation Systems and/or Devices3. Terminology3.1 For definitions relating to livestock, meat, and poultry evaluation systems, see Terminology F2463.3.2 Definitions of Terms Specific to This Standard:3.2.1 error, ndifference between the “true” value of a refe
6、rence material and the indication received from an electronicevaluation device or system.3.2.2 meat, nall edible products and edible by-products harvested by the meat-packing industry.3.2.3 reference material, nphysical object used as a basis for comparison or calibration.3.2.4 test, nprocedure for
7、determining a characteristic by direct measurement.3.2.5 tolerance, nvalue fixing the limit of allowable error or departure from true performance or value.3.2.6 value, measurement, ndata point or indication representing the outcome of a measurement or observation.4. Significance and Use4.1 Character
8、istics of livestock, meat, and poultry can be used to determine value. Devices have been and are currently underdevelopment to evaluate these characteristics. The use of this test method will assist manufacturers, users, and regulatingauthorities to refer to uniform test methods to determine if the
9、devices are accurate.5. Apparatus5.1 Reference materials may include, but are not limited to, test blocks to verify linear measurements for ultrasound and linearprobes, “phantom carcasses” to verify non-linear measurements used in devices that use magnetic energy absorption, photographicplates for v
10、isual imaging devices, or other means to verify a characteristic.1 This test method is under the jurisdiction ofASTM Committee F10 on Livestock, Meat, and Poultry Evaluation Systems and is the direct responsibility of SubcommitteeF10.20 on Device Performance Criteria.Current edition approved Sept. 1
11、, 2009April 1, 2015. Published September 2009May 2015. Originally approved in 2004. Last previous edition approved in 20082009 asF2343 08.F2343 09. DOI: 10.1520/F2343-09.10.1520/F2343-15.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceas
12、tm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from National Institute of Standards and Technology (NIST), 100 Bureau Dr., Stop 1070, Gaithersburg, MD 20899-1070, http:/www.nist.gov.This document is not an AST
13、M standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In al
14、l cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.2 Manufacturers provide reference materials to use in the initial setup a
15、nd calibration of evaluating devices before use; thesereference materials can be used as standards for ensuring accuracy after they are verified and documented by an independent thirdparty. Reference material shall be uniquely identified (for example, serial number) and retained for additional testi
16、ng andcalibration to ensure the accuracy of the device as it is being used over time.5.3 Verification of the reference material requires: (1) that the reference materials stated measurements are accurate (thisrequires that the error of the labeled measurements can not be greater than one-third of th
17、e smallest allowable error acceptablewhen the reference material is used to verify an evaluating device), and (2) the reference material is an appropriate proxy for thecharacteristic being evaluated by the device or system (the reference material is considered appropriate if it is has been designedt
18、o be used as a reference material, and it is constructed to retain its characteristics for a reasonable period of time under conditionsof normal use).6. Calibration and Standardization6.1 Reference MaterialThe user is responsible for ensuring that all reference materials used to test its evaluating
19、device havebeen verified as accurate by an independent third party. The frequency of this verification shall be every two years or less.6.1.1 When an evaluation device or system is being calibrated at initial setup or adjusted after it has been found to be out oftolerance, the user shall ensure that
20、 the device is adjusted as close as practicable to the indications of the reference material.7. ProcedureProcedures7.1 The production daily test for evaluating devices require a minimum of three readings from each third of the normal operatingrange of the device.7.2 Autofom Test Procedures:7.2.1 Tra
21、nsducer Test:7.2.1.1 Dry the transducer array so that no water is left.7.2.1.2 Test function is activated on the control panel.7.2.1.3 Wait 1 min to check that none of the transducers are starting automatically.7.2.1.4 Put some gel on the test block (reference material).7.2.1.5 The transducer is che
22、cked with the test block.7.2.1.6 Remove gel from transducer.7.2.1.7 Repeat 7.2.1.4 7.2.1.6 on all 16 transducers. Take ten measurements with the test block for each required measurementon each transducer.7.2.2 After each transducer test, the results will be recorded. At the end of a test series, the
23、 latest result from each transducerwill be written on the last line. If a transducer is approved more than nine times, an “X” will indicate ten or more approved tests.7.2.3 A complete test of the transducers requires that the test block be correctly placed on each transducer. It is important thatthe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF23432015STANDARDTESTMETHODFORLIVESTOCKMEATANDPOULTRYEVALUATIONDEVICES 牲畜 禽类 评价 设备 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-538455.html