1、Designation: F 2237 03An American National StandardStandard Test Method forPerformance of Upright Overfired Broilers1This standard is issued under the fixed designation F 2237; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method evaluates the energy consumption andcooking performance of overfired broilers. The food servic
3、eoperator can use this evaluation to select an overfired broilerand understand its performance and energy consumption.1.2 This test method is applicable to gas and electric uprightoverfired broilers having input rates greater than 60,000 Btu/h(gas overfired broilers) or 10kW (electric overfired broi
4、lers).1.3 The overfired broiler can be evaluated with respect tothe following (where applicable):1.3.1 Energy input rate (see 10.2),1.3.2 Temperature uniformity of the broiler cavity (see10.3),1.3.3 Preheat energy consumption and time (see 10.4),1.3.4 Pilot energy rate (if applicable) (see 10.5),1.3
5、.5 Idle energy rate (see 10.6), and1.3.6 Cooking energy efficiency and production capacity(see 10.7).1.4 The values stated in inch-pound units are to be regardedas standard. The SI units given in parentheses are for informa-tion only.1.5 This test method may involve hazardous materials,operations, a
6、nd equipment. This standard does not purport toaddress all of the safety concerns, if any, associated with itsuse. It is the responsibility of the user of this standard toestablish appropriate safety and health practices and deter-mine the applicability of regulatory limitations prior to use.2. Refe
7、renced Documents2.1 ASTM Standards:A 36/A 36M Specification for Carbon Structural Steel2D 3588 Practice for Calculating Heat Value, Compressibil-ity Factor, and Relative Density of Gaseous Fuels32.2 AOAC Document:AOAC Official Action 950.46 Air Drying to DetermineMoisture Content of Meat and Meat Pr
8、oducts42.3 ASHRAE Standard:ASHRAE Handbook of Fundamentals “Thermal and Re-lated Properties of Food and Food Materials,” Chapter 30,Table 1, 198952.4 ANSI Standard:ANSI Z83.11 Gas Food Service Equipment63. Terminology3.1 Definitions:3.1.1 broiler cavity, nthat portion of the overfired broilerin whic
9、h food products are heated or cooked.3.1.2 cooking energy effciency, nquantity of energy im-parted to the specified food product, expressed as a percentageof energy consumed by the overfired broiler during the cookingevent.3.1.3 cooking energy rate, naverage rate of energy con-sumption (Btu/h or kW)
10、 during the cooking energy efficiencytests.3.1.4 grate, broiler grate, nthe platform on which food isplaced while cooking in an overfired broiler.3.1.5 idle energy rate, nthe overfired broilers rate ofenergy consumption (kW or Btu/h), when empty, required tomaintain the broilers operating temperatur
11、e while not cooking.3.1.6 overfired broiler, nan appliance with a high tem-perature radiant heat source above a heavy duty, sliding gratefor cooking food, characterized by an open front cookingcavity and having an input rate greater than 60 000 Btu/h or10kW.NOTE 1The upright overfired broiler is dis
12、tinguished from the sala-mander and the cheese melter by its heavy duty, stand-alone constructionand high energy input rate (see Fig. 1).1This test method is under the jurisdiction of ASTM Committee F26 on FoodService Equipment and is the direct responsibility of Subcommittee F26.06 onProductivity a
13、nd Energy Protocol.Current edition approved March 10, 2003. Published April 2003.2Annual Book of ASTM Standards, Vol 01.04.3Annual Book of ASTM Standards, Vol 05.06.4Available from Association of Official Analytical Chemists, 1111 N. 19thStreet, Arlington, VA 22209.5Available from American Society o
14、f Heating, Refrigerating, and Air-Conditioning Engineers, Inc. (ASHRAE), 1791 Tullie Circle, NE, Atlanta, GA30329.6Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshoh
15、ocken, PA 19428-2959, United States.3.1.7 pilot energy rate, nrate of energy consumption(Btu/h) by an overfired broilers continuous pilot (if appli-cable).3.1.8 preheat energy, namount of energy consumed (Btuor kWh), by the overfired broiler while preheating its cavityfrom ambient temperature to the
16、 calibrated control set point.3.1.9 preheat time, ntime (min.) required for the overfiredbroiler cavity to preheat from ambient temperature to thecalibrated control set point.3.1.10 production capacity, nmaximum rate (lb/h) atwhich an overfired broiler can bring the specified food productto a specif
17、ied “cooked” condition.3.1.11 uncertainty, nmeasure of systematic and precisionerrors in specified instrumentation or measure of repeatabilityof a reported test result.4. Summary of Test Method4.1 The overfired broiler is connected to the appropriatemetered energy source, and the energy input rate i
18、s determinedto confirm that the appliance is operating within 5 % of thenameplate energy input rate.4.2 The broiler grate is covered with 5-in. (127-mm) diam-eter steel disks and the overfired broilers controls are set suchthat the broiling area does not exceed a maximum temperatureof 800F (315C). T
19、he temperature uniformity of the broilingarea is determined by monitoring thermocoupled steel disksplaced on the broiler grate.4.3 With the controls set such that the broiling area does notexceed 800F (315C), the amount of energy and time requiredto preheat the broiling area to 700F (260C) is determ
20、ined.4.4 The pilot energy rate is determined, when applicable, forgas overfired broilers.4.5 Idle energy rate is determined while maintaining thebroiler cavity at its operating temperature while not cooking.4.6 With the controls set such that the broiling area does notexceed 800F (315C), the overfir
21、ed broiler is used to cook5-oz boneless, skinless, chicken breasts to an internal tempera-ture of 170F. Cooking energy efficiency is determined for lightand heavy loading conditions.4.7 Production capacity is determined for the heavy loadingscenario.5. Significance and Use5.1 The energy input rate t
22、est is used to confirm that theoverfired broiler is operating properly prior to further testing.5.2 Temperature uniformity of the broiler cavity may beused by food service operators to select an overfired broilerwith the desired temperature gradients.5.3 Preheat energy and time can be useful to food
23、 serviceoperators to manage energy demands and to know how quicklythe overfired broiler can be ready for operation.5.4 Idle energy rate and pilot energy rate can be used toestimate energy consumption during non-cooking periods.5.5 Cooking energy efficiency is a precise indicator ofoverfired broiler
24、energy performance while cooking a typicalfood product under various loading conditions. If energyperformance information is desired using a food product otherthan the specified test food, the test method could be adaptedand applied. Energy performance information allows an enduser to better underst
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF22372003STANDARDTESTMETHODFORPERFORMANCEOFUPRIGHTOVERFIREDBROILERS 立式 旺火 烧烤 装置 性能 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-538145.html