ASTM F2199-2009(2014) Standard Test Method for Determining Dimensional Stability of Resilient Floor Tile after Exposure to Heat《测定弹性地板砖在热暴露后尺寸稳定性的标准试验方法》.pdf
《ASTM F2199-2009(2014) Standard Test Method for Determining Dimensional Stability of Resilient Floor Tile after Exposure to Heat《测定弹性地板砖在热暴露后尺寸稳定性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2199-2009(2014) Standard Test Method for Determining Dimensional Stability of Resilient Floor Tile after Exposure to Heat《测定弹性地板砖在热暴露后尺寸稳定性的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2199 09 (Reapproved 2014)Standard Test Method forDetermining Dimensional Stability of Resilient Floor Tileafter Exposure to Heat1This standard is issued under the fixed designation F2199; the number immediately following the designation indicates the year oforiginal adoption or, in the
2、 case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the changein linear dimensions of resilien
3、t floor tile after exposure to heat.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard does not purport to address all
4、 of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E177 Practice for Use
5、 of the Terms Precision and Bias inASTM Test MethodsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodF141 Terminology Relating to Resilient Floor CoveringsF2055 Test Method for Size and Squareness of ResilientFloor Tile by Dial Gage Method3. Terminology
6、3.1 Definitions are in accordance with Terminology F141unless otherwise indicated.4. Significance and Use4.1 The final appearance of an installed tile floor dependsupon several factors. These include but are not limited to sizeand squareness of the tile, the quality of joint cut, the qualityand prep
7、aration of the subfloor and the skill of the installer.Long term appearance of the installed floor is also dependenton but not limited to the ability of the tile to resist shrinkagedue to internal stress relief. This test method is used to measurethe ability of floor tile to retain its original dime
8、nsionsfollowing exposure to heat simulating a long service life atreasonable and expected temperatures.5. Apparatus5.1 Mechanical Convection-Type Oven, or equivalent, ca-pable of maintaining a temperature of 180 6 3.6F (82 6 2C),with inside dimensions large enough to hold several tileshorizontally o
9、n aluminum exposure plates.5.2 Specimen Exposure Plates, consisting of flat 14gage,0.0625in. (1.6mm), thick aluminum. The aluminum expo-sure plates may be contained in a rack, either fixed in orremovable from the rack, and should be at least 1 in. (25.4 mm)larger in each linear dimension than the li
10、near dimension of thespecimen tested. If contained in a rack, the spacing betweeneach plate should be at least 0.625in. (16mm). The rack shallbe constructed with all four sides open.5.3 Block and Dial Gage Assembly, as described in TestMethod F2055.5.4 Forced Air Cooling (Fan, Blower, etc.), may be
11、used foraccelerating specimen conditioning before heating and aftercooling exposure to ensure proper equilibrium of test specimen(see 6.1 and 7.1).6. Test Specimen6.1 The test specimen consists of a resilient floor tile.Typical floor tile dimensions are 9 by 9 in. (229 by 229 mm) or12 by 12 in. (305
12、 by 305 mm). Other sizes in square orrectangular dimensions may also be tested.7. Conditioning7.1 A conditioned room maintained at a temperature of 73.46 1.8F (23 6 1C) and 50 6 5 % relative humidity.8. Procedure8.1 Reference PlatesDifferent tile sizes, with respectivereference plates, can be specif
13、ied if the size and squarenessapparatus is designed to handle the testing and measurement ofalternate sizes.1This test method is under the jurisdiction ofASTM Committee F06 on ResilientFloor Coverings and is the direct responsibility of Subcommittee F06.30 on TestMethods - Performance.Current editio
14、n approved May 1, 2014. Published June 2014. Originallyapproved in 2002. Last previous edition approved in 2009 as F2199-09. DOI:10.1520/F2199-09R14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStanda
15、rds volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States18.2 Conditioning Before ExposureCondition the speci-mens at 73.4 6 1.8F (23 6 1C) and 50 6 5 % rel
16、ativehumidity for not less than 24 h prior to starting the test unlessotherwise specified.8.3 Conditions for MeasurementMeasure the tile speci-men (6.1) in the conditioning room (7.1).8.4 Calibration of Block and Dial Gage IndicatorsCalibrate the block and dial gage indicators as indicated in TestMe
17、thod F2055.8.5 Initial MeasurementPlace the tile specimen, afterconditioning (8.2), on the block and dial gage assembly (5.3)face up and measure in the machine direction (MD), ifidentifiable, and the across machine direction (AMD), ifidentifiable, according to the procedure in Test Method F2055.Thes
18、e points shall be marked as a reference on the tile so thatthe final measurements will be made at the same exactlocations. Measure the tile according to Test Method F2055and eliminating the squareness measurement step.8.6 ExposurePlace the tile specimen face up in the expo-sure rack (5.2) on the alu
19、minum exposure plates. Position theplates on racks in the heated cabinet (5.1)at1806 3.6F (826 2C) for 6 6 0.25 h. Expose the four open sides of the rackto the direction of the airflow within the cabinet so that thecirculating air passes freely over the tile specimens.8.7 Conditioning after Exposure
20、Remove the tile/plateassembly from the oven cabinet (5.1). Allow the assembly tocondition at room temperature (7.1) for at least 24 h. Weargloves when handling the hot aluminum plate.8.8 Final MeasurementsDetermine the dimensional sta-bility by measuring the change in tile size before and after theh
21、eat exposure for both the MD and AMD at the referencelocations. Remove the tile from the aluminum plate afterre-conditioning and re-measure on the block and dial gageassembly (5.3) according to 8.5. Make the measurements at thesame reference points as the initial measurements.NOTE 1Squareness measur
22、ements are not to be taken or recordedsince they are not directly considered in the dimensional stabilitydetermination.9. Calculations9.1 The final MD average measurements are subtractedfrom initial MD average measurements. The dimensionalstability is recorded and reported in inches (0.001 in.) Aneg
23、ative value indicates shrinkage, and a positive value indi-cates expansion.9.2 The final AMD average measurements are subtractedfrom initial AMD average measurements. The dimensionalstability is recorded and reported in inches (0.001 in.) Anegative value indicates shrinkage, and a positive value ind
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF219920092014STANDARDTESTMETHODFORDETERMININGDIMENSIONALSTABILITYOFRESILIENTFLOORTILEAFTEREXPOSURETOHEAT

链接地址:http://www.mydoc123.com/p-538023.html