《ASTM F2188-2002(2011) Standard Test Method for Determining the Effect of Variable Frequency Vibration on a Membrane Switch or Membrane Switch Assembly《测定隔膜开关或隔膜开关组配可变频率振动影响的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2188-2002(2011) Standard Test Method for Determining the Effect of Variable Frequency Vibration on a Membrane Switch or Membrane Switch Assembly《测定隔膜开关或隔膜开关组配可变频率振动影响的标准试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2188 02 (Reapproved 2011)Standard Test Method forDetermining the Effect of Variable Frequency Vibration on aMembrane Switch or Membrane Switch Assembly1This standard is issued under the fixed designation F2188; the number immediately following the designation indicates the year oforigi
2、nal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method establishes procedures for determiningthe effec
3、t of sinusoidal vibration, within the specified fre-quency range, on switch contacts, mounting hardware, adheredcomponent parts, solder or heat stakes, tactile devices, andcable or ribbon interconnects associated with a membraneswitch or membrane switch assembly.1.2 This standard does not purport to
4、 address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Terminology2.1 Definitions:2.1.1 contact closuret
5、he event at which a specified resis-tance is achieved on a membrane switch.2.1.2 critical resonance frequencyany point on the speci-men that is observed to have maximum amplitude or more thantwice that of the base input amplitude or support points.2.1.3 membrane switcha momentary switching device in
6、which at least one contact is on, or made of, a flexiblesubstrate.2.1.4 specified resistancemaximum allowable circuit re-sistance as measured between two test points whose internalcontacts, when held closed, complete a circuit.2.1.5 test pointstwo pre-selected conductive points in acircuit loop, pos
7、sibly including a switch.3. Significance and Use3.1 Vibration encountered in the field is not usually simpleharmonic.3.2 This test can be used to determine relative motionbetween parts, critical frequencies, adhesion strengths, loosen-ing of parts or other physical effects that can cause fatigue orf
8、ailure.3.3 Experience has shown that this test will expose potentialfailures associated with the electronic components of a mem-brane switch, where tests of lower levels will not.3.4 This practice can be used to qualify a membrane switchfor aerospace, medical and other applications.3.5 This test is
9、potentially destructive, intended for devicequalification.3.6 Either Test Condition A or B can be chosen, based uponthe intent of the test determined by the qualified engineer.4. Apparatus4.1 Vibration Fixture, capable of holding the unit under testand subjecting it to the specified random frequency
10、 andduration as described in the In-Process Test.4.2 Contact Closure Detection Device, (if test is performedunder load conditions), instrumentation capable of resolving aswitch opening time of greater than or equal to 1.0 ms.4.3 Resonant Detecting Instrumentation, (if determinationof critical resona
11、nce frequency is desired), capable of deter-mining the critical resonance frequency.5. ProcedureTest Condition A, 10 g5.1 Pre-Test Setup:5.1.1 Secure membrane switch on vibration test surfacewith appropriate fixturing.5.1.2 Connect switch detection leads to test points on themembrane switch (if cont
12、act closure is being monitored duringthe test).5.1.3 Function testing to be specified and performed againafter test completion for comparison.5.2 In-Process Test:5.2.1 Subject test unit to sinusoidal vibration varied infrequency from 10 to 500 Hz at a logarithmic rate of 0.5 octaveper minute for a d
13、uration of 18 cycles per each orthogonal axis(total of 56 times). The amplitude of the vibration shall be1This test method is under the jurisdiction of ASTM Committee F01 onElectronics and is the direct responsibility of Subcommittee F01.18 on MembraneSwitches.Current edition approved Feb. 1, 2011.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF218820022011STANDARDTESTMETHODFORDETERMININGTHEEFFECTOFVARIABLEFREQUENCYVIBRATIONONAMEMBRANESWITCHORMEMBRANESWITCHASSEMBLY

链接地址:http://www.mydoc123.com/p-537995.html