《ASTM F2160-2005 Standard Specification for Solid Wall High Density Polyethylene (HDPE) Conduit Based on Controlled Outside Diameter (OD)《外径受控的实心壁高密度聚乙烯导管的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2160-2005 Standard Specification for Solid Wall High Density Polyethylene (HDPE) Conduit Based on Controlled Outside Diameter (OD)《外径受控的实心壁高密度聚乙烯导管的标准规范》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2160 05An American National StandardStandard Specification forSolid Wall High Density Polyethylene (HDPE) Conduit Basedon Controlled Outside Diameter (OD)1This standard is issued under the fixed designation F 2160; the number immediately following the designation indicates the year of
2、original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers material, dimensional, work-mans
3、hip and performance requirements for polyethylene con-duit, duct and innerduct manufactured for use in a non-pressure application with communication, CATV, or powerwire and cables.1.2 HDPE conduit meeting the requirements of this standardshall be made as OD controlled solid wall, with or withoutinte
4、rnal or external ribs. The sizing shall be Iron Pipe Size(IPS) with noted exceptions in tables. The internal or externalsurface may contain a coextruded layer provided the finishedconduit meets the product requirements of this specification.1.3 The values stated in inch-pound units are to be regarde
5、das the standard. The values given in parentheses are providedfor information purposes only.1.4 The following precautionary caveat pertains only to thetest method portion, Section 6, of this specification. Thisstandard does not purport to address all of the safety concerns,if any, associated with it
6、s use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory require-ments prior to use.2. Referenced Documents2.1 ASTM Standards:2D 618 Practice for Conditioning Plastics for TestingD 638 Test Method fo
7、r Tensile Properties of PlasticsD 790 Test Methods for Flexural Properties of Unreinforcedand Reinforced Plastics and Electrical Insulating MaterialsD 792 Test Methods for Density and Specific Gravity (Rela-tive Density) of Plastics by DisplacementD 1238 Test Method for Flow Rates of Thermoplastics
8、byExtrusion PlastometerD 1505 Test Method for Density of Plastics by the Density-Gradient TechniqueD 1600 Terminology for Abbreviated Terms Relating toPlasticsD 1693 Test Method for Environmental Stress-Cracking ofEthylene PlasticsD 2122 Test Method for Determining Dimensions of Ther-moplastic Pipe
9、and FittingsD 2444 Test Method for Impact Resistance of Thermoplas-tic Pipe and Fittings by Means of a Tup (Falling Weight)D 2837 Test Method for Obtaining Hydrostatic DesignBasis for Thermoplastic Pipe Materials or Pressure DesignBasis for Thermoplastic Pipe ProductsD 3350 Specification for Polyeth
10、ylene Plastics Pipe andFittings MaterialsD 4883 Test Method for Density of Polyethylene by theUltrasound TechniqueF 412 Terminology Relating to Plastic Piping Systems3. Terminology3.1 DefinitionsGeneral terms used in this Specificationare as defined in Terminology F 412, and abbreviations are inacco
11、rdance with Terminology D 1600, unless otherwise speci-fied.3.2 Definitions of Terms Specific to This Standard:3.2.1 CATV, ncable television.3.2.2 conduit (duct), na tubular raceway for carryingpower, communications, or other wires and cables3.2.3 innerduct, na conduit installed inside a conduit.3.2
12、.4 kink, na crease across the conduit where it hasfolded from excessive bending.3.2.5 ribs, na series of ridges along the inside or outsidesurface of a conduit.3.2.6 true size, ndenotes the use of a sizing system thatrequires a nominal inside diameter to be the equal or greaterthan the stated nomina
13、l size of the conduit (that is, a 114 in.conduit has a minimum ID of 1.25 in.).1This specification is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.26 on OlefinBased Pipe.Current edition approved Mar. 1, 2005. Published Mar
14、ch 2005. Originallyapproved in 2001. Last previous edition approved in 2001 as F216001.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summar
15、y page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4. Materials4.1 Polyethylene PlasticsThe PE materials used to makeconduit under this Specification shall meet or exceed thefollowing requirements:4.1.1 Compoun
16、dPE resin compounds shall be classifiedin accordance with Specification D 3350 and Table 1.4.1.2 Rework MaterialClean polyethylene compoundfrom the manufacturers own production may be re-extrudedinto conduit, either alone or blended with virgin compound.Conduit containing the rework material shall m
17、eet all thematerial and product requirements of this specification.4.1.3 Material Physical Properties:4.1.3.1 DensityDensity values shall be determined byTest Methods D 792, D 1505,orD 4883.4.1.3.2 Melt IndexA melt index of up to 0.55 grams/10minutes as per Test Method D 1238 Condition 190/2.16 isal
18、lowable provided that all other material requirements speci-fied in Table 1 are met.4.1.3.3 Slow Crack GrowthAn ESCR as per Test MethodD 1693, condition B, 10 % Igepal requirement of F10 96 h isallowable provided that all other material requirements inTable 1 are met.4.2 Coextruded LayerAny material
19、 used as a coextrudedlayer on the inside or outside surface of the PE conduit shalladhere to the surface of the PE and shall not delaminate innormal use. It shall not degrade or lower the performance ofthe PE conduit.4.3 Aerial ApplicationsPE material for black conduit inlong-term above ground appli
20、cations, such as aerial suspen-sion, shall be stabilized with a minimum of 2 % by weightcarbon black having an average particle size less than or equalto 20 nanometers.4.4 Outdoor Storage Stability:4.4.1 Black ConduitPE material for black conduit innon-UV exposed applications shall be stabilized wit
21、h a mini-mum of 2 % by weight carbon black in accordance withSpecification D 3350.NOTE 1Acceptable cell for Color and UV resistance properties inTable 1 may be achieved by utilizing a precompounded material or byblending a base natural material with a color concentrate.4.4.2 Colored ConduitPE materi
22、al for colored conduit innon-UV exposed applications shall be suitably protectedagainst UV degradation so that conduit may be stored outsideand uncovered for a period of not less than one year.5. Requirements5.1 WorkmanshipEach layer of the conduit shall be ho-mogeneous throughout and essentially un
23、iform in color, opac-ity, density and other properties. The inside and outsidesurfaces shall be free of visible cracks, holes, blisters, voids,foreign inclusions, or other deleterious defects.5.2 Dimensions and Tolerances:5.2.1 Outside DiametersThe outside diameters and toler-ances shall be as shown
24、 in Table 2 for IPS sizes, Table 3 forSchedules 40 and 80 and Table 4 for “true” sizing, whenmeasured in accordance with Test Method D 2122.5.2.2 Wall ThicknessThe wall thicknesses and tolerancesshall be as shown in Tables 5-8 for IPS sizes, Table 9 forSchedule 40, Table 10 for Schedule 80, and Tabl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF21602005STANDARDSPECIFICATIONFORSOLIDWALLHIGHDENSITYPOLYETHYLENEHDPECONDUITBASEDONCONTROLLEDOUTSIDEDIAMETEROD

链接地址:http://www.mydoc123.com/p-537907.html