1、Designation: F 2143 04An American National StandardStandard Test Method forPerformance of Refrigerated Buffet and Preparation Tables1This standard is issued under the fixed designation F 2143; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers evaluation of the energy con-sumption and refrigeration performance of
3、refrigerated buffetand preparation tables. The food service operator can use thisevaluation to select a refrigerated buffet and preparation tableand understand its energy performance.1.2 This test method is applicable to electric self-containedrefrigerators used for holding and displaying refrigerat
4、ed foodin an open area.1.3 The refrigerated buffet and preparation table can beevaluated with respect to the following (where applicable):1.3.1 Maximum energy input rate, or maximum currentdraw (10.1),1.3.2 Thermostat calibration (10.4),1.3.3 Lid up energy rate and temperature performance(10.5), and
5、1.3.4 Lid down energy rate (10.6).1.4 The values stated in inch-pound units are to be regardedas standard. The SI units given in parentheses are for informa-tion only.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of
6、the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 NSF Standard:2NSF, Listing-Food Equipment and Related, Componentsand MaterialANSI/NSF 7 Commercial Refrigerators and Free
7、zers2.2 ASHRAE Guideline:3ASHRAE Guideline 2-1986 (RA90) Engineering Analysisof Experimental Data2.3 ANSI/ASHRAE Standards:4ANSI/ASHRAE 117 Method of Testing Closed Refrigera-torsANSI/ASHRAE 72 Method of Testing Open Refrigeratorsfor Food Stores2.4 Food and Drug Administration, U.S. Public HealthSer
8、vice Regulation:5Food Code, 19993. Terminology3.1 Definitions:3.1.1 box car average, na locations thermocouple tem-perature averaged over a 1-h period. During the 4-h holdingenergy rate test, thermocouple temperatures are recorded at5-min intervals. The first box car average is the average ofreading
9、s 1 through 12. The second box car average is theaverage of temperature readings 2 through 13, and so on.63.1.2 energy input rate, npeak rate at which a refrigeratedbuffet and preparation table consumes energy (kW).3.1.3 lid down energy rate, naverage rate of buffet/preparation table energy consumpt
10、ion (kW) with the upper lidclosed over the refrigerated rail containing pans of syntheticfood.3.1.4 lid up energy rate, naverage rate of buffet/preparation table energy consumption (kW) while it maintainsthe temperature of pans of synthetic food in the refrigerated railwith the upper lid open and th
11、e cabinet doors closed.3.1.5 production capacity, nmaximum volumetric storagecapacity (ft3(m3) at which the refrigerated buffet and prepa-ration tables open display area can hold using a specifiedcontainer filled to12 in. of the container rim.3.1.6 refrigerated buffet and preparation table, nbuffet/
12、preparation table herein, equipment designed with a refriger-ated open top or open condiment rail.3.1.7 refrigerated buffet table or unit, nequipment de-signed with mechanical refrigeration that is intended to receive1This test method is under the jurisdiction of ASTM Committee F26 on FoodService Eq
13、uipment and is the direct responsibility of Subcommittee F26.06 onProductivity and Energy Protocol.Current edition approved Oct. 1, 2004. Published October 2004. Originallyapproved in 2001. Last previous edition approved in 2001 as F 214301.2Available from NSF International, P.O. Box 130140, 789 N.
14、Dixboro Rd., AnnArbor, MI 48113-0140.3Available from American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Inc. (ASHRAE), 1791 Tullie Circle, NE, Atlanta, GA30329.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036.5Availab
15、le from National Technical Information Service (NTIS), U.S. Depart-ment of Commerce, 5285 Port Royal Rd., Springfield, VA 22161.6Based on ANSI/NSF 7, available from NSF International, P.O. Box 130140,Ann Arbor, MI 48113-0140.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Con
16、shohocken, PA 19428-2959, United States.refrigerated food and maintain food product temperatures andis intended for customer service such as a salad bar. A unit mayor may not be equipped with a lower refrigerated compart-ment.63.1.8 refrigerated food preparation unit, nequipment de-signed with a ref
17、rigerated open top or open condiment rail suchas refrigerated sandwich units, pizza preparation tables, andsimilar equipment. The unit may or may not be equipped witha lower refrigerated compartment.63.1.9 self-contained refrigerator, na refrigerator whosecondensing unit is attached as an integral c
18、omponent of theunit.63.1.10 storage refrigerator or freezer, na refrigerator orfreezer designed for cold storage of nonfrozen or frozen foods.3.1.11 storage capacity, nmaximum volumetric storagecapacity (ft3(m3) as determined by the manufacturer at whichthe refrigerated buffet or preparation tables
19、storage componentcan hold food.3.1.12 test method, na definitive procedure for the iden-tification, measurement, and evaluation of one or more quali-ties, characteristics, or properties of a material, product,system, or service that produces test results.3.1.13 uncertainty, nmeasure of systematic an
20、d precisionerrors in specified instrumentation or measure of repeatabilityof a reported test result.4. Summary of Test Method4.1 Energy input rate is determined to confirm that thebuffet/preparation table is operating within 5 % of the name-plate energy input rate.4.2 2 Buffet/preparation table ener
21、gy rate is determined withthe upper lid in the raised and lowered positions while the unitis used to maintain the temperature of a synthetic food productbeing held in the refrigerated rail.4.3 Production capacity is determined by measuring theamount of synthetic food that the refrigerated rail can h
22、old,using a specified container filled to12 in. of the container rim.5. Significance and Use5.1 The energy input rate test is used to confirm that thebuffet/preparation table is operating properly prior to furthertesting.5.2 Lid up energy rate is a precise indicator of buffet/preparation table energ
23、y performance under the test loadingcondition. Lid down energy rate is a precise indicator ofbuffet/preparation table energy performance under a simulatedovernight operating condition. This information enables thefood service operator to consider energy performance whenselecting a buffet/preparation
24、 table.5.3 Production capacity is used by food service operators tochoose a buffet/preparation table that matches their food outputrequirements.6. Apparatus6.1 Analytical Balance Scale, for measuring weights up to25 lb, with a resolution of 0.01 lb and an uncertainty of 0.01 lb.6.2 Electric Mixer, f
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF21432004STANDARDTESTMETHODFORPERFORMANCEOFREFRIGERATEDBUFFETANDPREPARATIONTABLES 冷藏柜 食品 加工 性能 标准

链接地址:http://www.mydoc123.com/p-537857.html