ASTM F2090-2001a(2007) Standard Specification for Window Fall Prevention Devices With Emergency Escape (Egress) Release Mechanisms《带有紧急逃生(出口)分离机构的防窗跌落装置用标准规范》.pdf
《ASTM F2090-2001a(2007) Standard Specification for Window Fall Prevention Devices With Emergency Escape (Egress) Release Mechanisms《带有紧急逃生(出口)分离机构的防窗跌落装置用标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2090-2001a(2007) Standard Specification for Window Fall Prevention Devices With Emergency Escape (Egress) Release Mechanisms《带有紧急逃生(出口)分离机构的防窗跌落装置用标准规范》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2090 01a (Reapproved 2007)Standard Specification forWindow Fall Prevention Devices With Emergency Escape(Egress) Release Mechanisms1This standard is issued under the fixed designation F 2090; the number immediately following the designation indicates the year oforiginal adoption or, i
2、n the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONThis consumer safety specification addresses window fall prevention devices that
3、protect againstpotential falls by children aged five years and under from windows.A special study2by the U.S. Consumer Product Safety Commission indicates that young childrenare at high risk of death and serious injury from window falls. Children aged five and younger accountfor a higher percentage
4、of window fall fatalities and injuries.3Window fall prevention devices usually differ in purpose and application from security/burglar bars.The general purpose of a window fall prevention device is to prevent a child age five or younger fromfalling from a window. The general purpose of a security ba
5、r is to prevent unlawful entry through awindow. Generally window fall prevention devices and security bars are two separate devices.However, a security bar could be used as a fall prevention device if it meets the requirements of thisspecification.1. Scope1.1 This specification establishes requireme
6、nts for devicesintended to address the risk of injury and death associated withaccidental falls from windows by children five years old andyounger.1.2 This specification is not intended to meet the uniquerequirements of Americans With Disabilities Act (ADA).1.3 This specification applies to window f
7、all preventiondevices that are to be used on any windows, including thosethat are designated for emergency escape (egress) and rescue(ingress).NOTE 1A separate safety specification, Safety Specification F 2006,covers window fall prevention devices for non-emergency escape (egress)and rescue (ingress
8、) windows in installations more than 75 feet4(23 m)above ground level in multiple family dwelling buildings.1.4 This standard does not purport to address all safetyconcerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety andhealt
9、h practices and to determine the applicability of regula-tory limitations prior to use.1.5 The values stated in inchpound units are to be regardedas the standard. The SI values given in parentheses are forinformation only.2. Referenced Documents2.1 ASTM Standards:5F 977 Consumer Safety Specification
10、 for Infant WalkersF 1487 Consumer Safety Performance Specification forPlayground Equipment for Public UseF 2006 Safety Specification for Window Fall PreventionDevices for Non-Emergency Escape (Egress) and Rescue(Ingress) Windows2.2 Code of Federal Regualtions:616 CFR 1500.53 Test Methods for Simula
11、ting Use andAbuse of Toys and Other Articles Intended for Use byChildren Over 36 But Not Over 96 Months of Age, (f)(3)Testing Procedure1This specification is under the jurisdiction of ASTM Committee F15 onConsumer Products and is the direct responsibility of Subcommittee F15.38 onWindow Fall Prevent
12、ion.Current edition approved April 1, 2007. Published July 2007. Originallyapproved in 2001. Last previous edition approved in 2001 as F 2090 01a.2U.S. Consumer Product Safety Commission, Special Window Falls Study,conducted in 1991.3U.S. Consumer Product Safety Commission, Special Window Falls Stud
13、y,conducted in 1991 and “Window Safety: Data and Patterns Related to Entrapmentsand Accidental Falls from Windows,” prepared by Andersen Corporation.Research Report F15-1002 available through ASTM41994 Uniform Building Code Handbook, Section 1807(a) and 2000 Interna-tional Building Code, Section 403
14、.1, Special Provisions for Groups B and R1,January 2000.5For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.6Code
15、 of Federal Regulations, available from U.S. Government Printing Office,Washington, DC 20402.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.16 CFR 1508.6(b) Requirements for Full-Size Baby CribsCPSC 16 CFR Chapter 11 (1-1-87 Edition
16、) Part 1201 SafetyStandard for Architectural Glazing Materials2.3 ANSI Standards:7ANSI Z535.4 Product Safety Signs and LabelsANSI Z97.1-1984 Safety Glazing Materials Used in Build-ings Safety Performance Specifications and Methods ofTest (Tempered Glass Impact Test)3. Terminology3.1 Definitions of T
17、erms Specific to This Standard:3.1.1 emergency escape (egress) and rescue (ingress) win-dow, na window intended for emergency escape (egress) andrescue (ingress) during an emergency situation such as fire, gasleak, etc., as defined by the prevailing applicable building andfire codes.3.1.2 release me
18、chanism for emergency escape (egress) andrescue (ingress) window fall prevention device, na means ofopening a window fall prevention device to provide a clearopening space for the purpose of emergency escape or rescue.3.1.3 window, nan opening constructed in a wall or a roofto admit light and/or air
19、 to any enclosure.3.1.4 window fall prevention device, na product installedinto an existing window opening, and in conjunction with theproperly functioning window unit, for the purpose of prevent-ing children five years old or younger from falling from or outof an open window.3.1.5 window falls, na
20、fall from or out of a window.4. General Requirements4.1 Window fall prevention devices shall be constructed soas to prohibit the free passage of a 4.0-in. (102-mm) diameterrigid sphere8at any point, during or after testing as specified inSection 8, when the window fall prevention device is installed
21、in accordance with the manufacturers instructions.4.2 The distance between window fall prevention devicestructural members or components after all testing is conductedshall not exceed 4.0 in. (102 mm) when a 60-lbf9(267-N)direct force is applied in accordance with the test method in8.2.4.3 Window fa
22、ll prevention devices shall be designed withrelease mechanisms to allow for emergency escape (egress)without the need for special tools or special knowledge.4.3.1 Operation of emergency escape (egress) mechanismsshall be accomplished with a minimum amount of effort fromthe inside of the building, wh
23、ether the window fall preventiondevice is mounted inside or outside the building.4.3.2 Release of the emergency escape (egress) mechanismshall require no more than 15 lbf (66 N) of force.104.3.3 The emergency escape (egress) release mechanismshall consist of a double-action device requiring two dist
24、inctactions to operate.11Opening the window fall preventiondevice shall not be counted as one of the two required actions.4.3.4 The emergency escape (egress) release mechanismshall operate properly in all types of weather.4.3.5 Emergency escape (egress) releases shall have theiroperating mechanisms
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF20902001A2007STANDARDSPECIFICATIONFORWINDOWFALLPREVENTIONDEVICESWITHEMERGENCYESCAPEEGRESSRELEASEMECHANISMS

链接地址:http://www.mydoc123.com/p-537711.html