1、Designation: F922 01 (Reapproved 2011)An American National StandardStandard Test Method forMotor Life Evaluation of an Electric Motorized Nozzle1This standard is issued under the fixed designation F922; the number immediately following the designation indicates the year of originaladoption or, in th
2、e case of revision, the year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the motorized nozzle used withhousehold or commercial vacuum clean
3、er systems, that is,combination cleaners.1.2 This test method provides a test for determining oper-ating motor life in hours by an accelerated laboratory proce-dure. The motors are tested while mounted and operated in themotorized nozzle.1.3 This test method covers only the motorized nozzle. Thesyst
4、em used to provide the airflow source is not underconsideration.1.4 This test method is limited to the determination of motorlife for an electrically powered household or commercialmotorized nozzle.1.5 The values stated in inch-pound units are to be regardedas the standard. The values given in paren
5、theses are forinformation only.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitatio
6、ns prior to use.2. Referenced Documents2.1 ASTM Standards:2D75 Practice for Sampling AggregatesE337 Test Method for Measuring Humidity with a Psy-chrometer (the Measurement of Wet- and Dry-Bulb Tem-peratures)F431 Specification for Air Performance Measurement Ple-num Chamber for Vacuum CleanersF608 T
7、est Method for Evaluation of Carpet Embedded DirtRemoval Effectiveness of Household/Commercial VacuumCleanersF655 Specification for Test Carpets and Pads for VacuumCleaner Testing3. Terminology3.1 Description of Term Specific to This Standard:3.1.1 motor lifelimited by failure of the motor. Failure
8、ismotor stoppage.3.1.1.1 DiscussionAny failure integral with the motorsuch as armature assembly, field assembly, housing(s) bear-ings, motor cooling fan, carbon brush assemblies, motor-mounted nonresettable thermal protective devices, or any othercomponent judged to be integral with the motor shall
9、be judgedas motor stoppage.4. Significance and Use4.1 The test results provide an indication of the motor life ofan electric motorized nozzle. End of motor life will be judgedin accordance with Section 3.5. Apparatus and Materials5.1 Voltage Regulator System, to control the input voltage tothe vacuu
10、m cleaner. The regulator system shall be capable ofmaintaining rated voltage 61 % and rated frequency 61Hzofthe motorized nozzle having a wave form that is essentiallysinusoidal with 3 % maximum harmonic distortion for theduration of the test.5.2 Voltmeter, to provide measurements accurate to within
11、61%.5.3 Timer and Switch, having the capacity to control theoff/on duty cycle of the nozzle and air flow source during thelife test.5.4 Wattmeter, to provide measurements accurate to within1%.5.5 Sharp-Edge Orifice Plate,a114-in. (32-mm) diametershall be in accordance with the orifice plate illustra
12、ted inSpecification F431.5.6 Plenum Chamber, conforming to the plenum chamberspecifications in Specification F431.5.7 Water Manometer, or equivalent instrument measuringin increments of 0.1 in. (2.54 mm).1This test method is under the jurisdiction ofASTM Committee F11 on VacuumCleaners and is the di
13、rect responsibility of Subcommittee F11.30 on Durability-Reliability.Current edition approved Nov. 1, 2011. Published March 2012. Originallyapproved in 1988. Last previous edition approved in 2006 as F922 01 (2006).DOI: 10.1520/F0922-01R11.2For referenced ASTM standards, visit the ASTM website, www.
14、astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.8 Ba
15、rometer, with an accuracy of 60.05 in. Hg (1.27 mmHg), capable of measuring uncorrected barometric pressurewith scale divisions of 0.02 in. (0.51 mm) or finer.5.9 Thermometer, having a range of at least 18 to 80F (8to +27C) and graduated in 1F (0.5C) increments.5.10 Psychrometer, meeting the require
16、ments of TestMethod E337 with thermometers graduated in increments of1F (0.5C).5.11 Test Carpet, conforming to the level loop carpet asdescribed in Specification F655.Acarpet that provides equiva-lent nozzle loading results may be used.5.12 Carpet Padding (optional), if used, the test carpetpadding
17、will conform to the padding described in SpecificationF655.5.13 Test Cleaner or Airflow SourceThe motorized nozzlemotor life evaluation tests shall be conducted using the airflowsource and voltage resulting from the components whichcomprise the combination system with which the motorizednozzle is to
18、 be used. If used with several systems, the one withthe maximum airflow shall be used.5.13.1 OptionA simulated airflow source and adjustedvoltage may be used if they are equal to or exceed thecombination system with which the motorized nozzle is to beused.5.14 Test FixtureA moving surface, covered b
19、y the testcarpet supported on the test pad, which moves with a horizon-tal reciprocating motion, for a stroke distance of 27 in. (686mm) in each direction at the average rate of 1.8 ft/s (0.55 mps),which results in 24 cpm (forward and back). This motion shallbe generated by rotating a 13.5-in. (343-
20、mm) radius arm thatshall be connected to the platform with an arm at least 24 in.(610 mm) long or equivalent. This device shall provide meansto hold the motorized nozzle fixed by its handle stationary inthe operating position while it is in contact with the recipro-cating surface.5.14.1 OptionThe mo
21、torized nozzle can be movedthrough the same cycle as stated in 5.14 while the carpetedplatform is held stationary. See Fig. 1. For either option, thereciprocating motion shall follow the same duty cycle asspecified for the vacuum cleaner or airflow source and motor-ized nozzle in 7.7. For the option
22、al test fixture of Fig. 1, thereciprocating arm must be at either end of its horizontal motionat the start of each “on” portion of the cycle. The vacuumcleaner or airflow source shall be stationary and positioned sothat the hose will be submitted to minimum stresses.5.15 Test Dirt, Wedron sand/talc
23、mixture. See Annex A1.6. Sampling6.1 Test a minimum of three units (or a larger sample size ifdesired) of similar models using the same motor style andamperage. Select all samples at random in accordance withgood statistical practice. Results shall provide an 80 % confi-dence level within 610 % of t
24、he mean value. If not, testadditional samples or reduce the results by the penalty factor ascalculated in 7.12.7. Procedure7.1 Determine initial performance. The suction of thecleaner or airflow source with the motorized nozzle attached isto be determined to ensure that no leaks develop to reduce lo
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF92220012011STANDARDTESTMETHODFORMOTORLIFEEVALUATIONOFANELECTRICMOTORIZEDNOZZLE 电动 喷头 电动机 寿命 评估 标准

链接地址:http://www.mydoc123.com/p-537564.html