ASTM F876-2015 Standard Specification for Crosslinked Polyethylene (PEX) Tubing《交联聚乙烯 (PEX) 管的标准规格》.pdf
《ASTM F876-2015 Standard Specification for Crosslinked Polyethylene (PEX) Tubing《交联聚乙烯 (PEX) 管的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM F876-2015 Standard Specification for Crosslinked Polyethylene (PEX) Tubing《交联聚乙烯 (PEX) 管的标准规格》.pdf(13页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F876 13aF876 15 An American National StandardStandard Specification forCrosslinked Polyethylene (PEX) Tubing1This standard is issued under the fixed designation F876; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the
2、 year of last revision.Anumber in parentheses indicates the year of last reapproval.Asuperscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers crosslinked polyethylene (PEX) tubing that incorporates an optional polymeric inner, m
3、iddle orouter layer and that is outside diameter controlled, made in nominal SDR9 tubing dimension ratios except where noted, andpressure rated for water at three temperatures (see Appendix X1). Included are requirements and test methods for material,workmanship, dimensions, burst pressure, hydrosta
4、tic sustained pressure, excessive temperature pressure, environmental stresscracking, stabilizer functionality, bent-tube hydrostatic pressure, oxidative stability in potable chlorinated water, and degree ofcrosslinking. Requirements for tubing markings are also given.1.2 The text of this specificat
5、ion references notes, footnotes, and appendixes which provide explanatory material. These notesand footnotes (excluding those in tables and figures) shall not be considered as requirements of the specification.1.3 The values stated in inch-pound units are to be regarded as standard. The values given
6、 in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.4 The following safety hazards caveat pertains only to the test methods portion, Section 7, of this specification:This standarddoes not purport to address all of the safet
7、y concerns, if any, associated with its use. It is the responsibility of the user of thisstandard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plas
8、tics for TestingD792 Test Methods for Density and Specific Gravity (Relative Density) of Plastics by DisplacementD1505 Test Method for Density of Plastics by the Density-Gradient TechniqueD1598 Test Method for Time-to-Failure of Plastic Pipe Under Constant Internal PressureD1599 Test Method for Resi
9、stance to Short-Time Hydraulic Pressure of Plastic Pipe, Tubing, and FittingsD1600 Terminology for Abbreviated Terms Relating to PlasticsD1898 Practice for Sampling of Plastics (Withdrawn 1998)3D2122 Test Method for Determining Dimensions of Thermoplastic Pipe and FittingsD2765 Test Methods for Dete
10、rmination of Gel Content and Swell Ratio of Crosslinked Ethylene PlasticsD2837 Test Method for Obtaining Hydrostatic Design Basis for Thermoplastic Pipe Materials or Pressure Design Basis forThermoplastic Pipe ProductsD3895 Test Method for Oxidative-Induction Time of Polyolefins by Differential Scan
11、ning CalorimetryF412 Terminology Relating to Plastic Piping SystemsF1281 Specification for Crosslinked Polyethylene/Aluminum/Crosslinked Polyethylene (PEX-AL-PEX) Pressure PipeF2023 Test Method for Evaluating the Oxidative Resistance of Crosslinked Polyethylene (PEX) Tubing and Systems to HotChlorin
12、ated WaterF2657 Test Method for Outdoor Weathering Exposure of Crosslinked Polyethylene (PEX) Tubing2.2 ANSI Standard:B36.10 Standards Dimensions of Steel Pipe (IPS)41 This specification is under the jurisdiction of ASTM Committee F17 on Plastic Piping Systems and is the direct responsibility of Sub
13、committee F17.26 on Olefin BasedPipe.Current edition approved Aug. 1, 2013June 1, 2015. Published August 2013September 2015. Originally approved in 1984. Last previous edition approved 2013 asF876 13.F876 13a. DOI: 10.1520/F0876-13A.10.1520/F0876-15.2 For referencedASTM standards, visit theASTM webs
14、ite, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 The last approved version of this historical standard is referenced on www.astm.org.4 Available from American
15、 National Standards Institute (ANSI), 25 W. 43rd St., 4th Floor, New York, NY 10036, http:/www.ansi.org.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be techni
16、cally possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this s
17、tandardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States12.3 Federal Standard:FED-STD-123 Marking for Shipment (Civil Agencies)52.4 Military Standard:MIL-STD-129 Marking for Shipment and Storage52.5 NSF Standard:NSF/ANSI 14 for Plastic
18、Piping Components and Related Materials62.6 ISO Standards:4ISO 1167 Thermoplastics pipes, fittings and assemblies for the conveyance of fluids - Determination of the resistance to internalpressure - Part 1: General methodISO 13760 Plastics pipes for the conveyance of fluids under pressure - Miners r
19、ule - Calculation method for cumulativedamageISO R 161-1690 Pipes of Plastic Materials for the Transport of Fluids (Outside Diameters and Nominal Pressures) Part 1, MetricSeries2.7 PPI Standard:7PPI TR-4 PPI Listing of Hydrostatic Design Basis (HDB), Strength Design Basis (SDB), Pressure Design Basi
20、s (PDB) andMinimum Required Strength (MRS) Ratings for Thermoplastic Piping Materials or Pipe3. Terminology3.1 DefinitionsDefinitions are in accordance with Terminology F412, and abbreviations are in accordance with TerminologyD1600, unless otherwise specified. The abbreviation for crosslinked polye
21、thylene is PEX. Plastic tubing denotes a particulardiameter schedule of plastic pipe in which outside diameter of the tubing is equal to the nominal size plus 18 in. Plastic pipe outsidediameter schedule conforms to ANSI B36.10.3.2 Definitions of Terms Specific to This Standard:3.2.1 crosslinked pol
22、yethylenea polyethylene material which has undergone a change in molecular structure using a chemicalor a physical process whereby the polymer chains are chemically linked.5 Available from Standardization Documents Order Desk, DODSSP, Bldg. 4, Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098
23、, http:/www.dodssp.daps.mil.DLA Document Services Building 4/D 700 Robbins Avenue Philadelphia, PA 19111-5094 http:/quicksearch.dla.mil/6 Available from NSF International, P.O. Box 130140, 789 N. Dixboro Rd., Ann Arbor, MI 48113-0140, http:/www.nsf.org.7 Plastics Pipe Institute (PPI), 105 Decker Cou
24、rt, Suite 825 Irving TX, 75062. http:/www.plasticpipe.orgTABLE 1 Wall Thickness and Tolerances for Nominal PEX SDR 9Plastic TubingANominal Tubing Minimum WallThickness Tolerancein. mm in. mm in. mm18 3 0.047B 1.19B +0.007 +0.1814 7 0.062B 1.57B +0.010 +0.25516 8 0.064 1.63 +0.010 +0.2538 10 0.070B 1
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF8762015STANDARDSPECIFICATIONFORCROSSLINKEDPOLYETHYLENEPEXTUBING 交联 聚乙烯 PEX 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-537447.html