ASTM F875-1994(2009) Standard Test Method for Evaluation of Large Area Density and Background on Office Copiers.pdf
《ASTM F875-1994(2009) Standard Test Method for Evaluation of Large Area Density and Background on Office Copiers.pdf》由会员分享,可在线阅读,更多相关《ASTM F875-1994(2009) Standard Test Method for Evaluation of Large Area Density and Background on Office Copiers.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 875 94 (Reapproved 2009)Standard Test Method forEvaluation of Large Area Density and Background on OfficeCopiers1This standard is issued under the fixed designation F 875; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisi
2、on, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the description and method ofuse for a density and background test target for
3、office copierimage evaluation.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitation
4、s prior to use. For specificprecautionary statements, see Section 8.2. Referenced Documents2.1 ASTM Standards:2E 1347 Test Method for Color and Color-Difference Mea-surement by Tristimulus ColorimetryF 335 Terminology Relating to Electrostatic ImagingF 360 Practice for Image Evaluation of Electrosta
5、tic Busi-ness Copies2.2 ASTM Adjunct:Density Target Test Sheets32.3 ANSI Standards:PH 2.17 Density measurementsGeometric conditions forreflection density4PH 2.18 Density measurementsSpectral conditions43. Terminology3.1 DefinitionsFor definitions of terms used in this testmethod, refer to Terminolog
6、y F 335.4. Summary of Test Method4.1 The standard test target is used to evaluate copy densityand background. The method of image evaluation using thistest target is given.5. Significance and Use5.1 The copy image quality is affected by many factors;including the copier, supplies, and environmental
7、conditions.The density and background image quality is particularlysignificant relative to aesthetic appearance, the visual impres-sion of blackness, and the ability to distinguish informationfrom background.5.2 The test target may also be used to evaluate the copier orsupplies.6. Apparatus6.1 Refle
8、ction Densitometer, meeting the requirements ofANSI PH 1.17 and PH 1.18, capable of measuring the smallestsolid circle (of the test target) which has a diameter of 6 mm.6.2 Reflectometer, meeting the requirements of Test MethodE 1347.7. Materials7.1 Test Target, for the evaluation of density and bac
9、k-ground image quality. It shall have the same configuration andlayout as shown in Fig. 1.38. Precautions8.1 This test target can be used to measure density andbackground for different copier conditions (machine adjust-ment, machine configuration, supplies, environment, etc.).Careful notation of the
10、se conditions should be made so thatcomparison tests can be made.8.2 The color and type of copy paper used will affect thedensity and background measurements.8.3 The method of fixing (fusing) of the image on the copymay affect the degree of gloss and may affect the differencebetween the perceived de
11、nsity and measured reflective density.1This test method is under the jurisdiction ofASTM Committee F05 on BusinessImaging Products and is the direct responsibility of Subcommittee F05.04 onElectrostatic Imaging Products.Current edition approved Feb. 1, 2009. Published February 2009. Originallyapprov
12、ed in 1984. Last previous edition approved in 2003 as F 875 94(2003)1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM
13、 website.3Available from ASTM International Headquarters. Order Adjunct No.ADJF0875. Original adjunct produced in 1994.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 100 Barr Harbor Drive,
14、PO Box C700, West Conshohocken, PA 19428-2959, United States.9. Procedure9.1 Using the test target in 7.1, establish a procedure(Practice F 360) for producing copies in a controlled manner.Evaluate the copy system at the site of its proposed installationunder the line voltage conditions which normal
15、ly apply. Read,understand, and follow the manufacturers instructions onoperation of the copier.9.1.1 Load supplies into the copier. Follow manufacturersdirections for adjustments of various controls.9.1.2 Turn on the copier.9.1.3 Set exposure control, if one is provided, to either endof the exposure
16、 range.9.1.4 Using test target, make a copy. Note exposure setting,if copier has an exposure control, and date on copy, as well asinformation concerning temperature and relative humidity.9.1.5 Vary exposure control, if one is provided, and makecopies at various settings. Note setting, date, temperat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF87519942009STANDARDTESTMETHODFOREVALUATIONOFLARGEAREADENSITYANDBACKGROUNDONOFFICECOPIERSPDF

链接地址:http://www.mydoc123.com/p-537437.html