ASTM F874-1998(2014) Standard Test Method for Temperature Measurement and Profiling for Microwave Susceptors《微波感受器温度测量及外形图绘制的标准试验方法》.pdf
《ASTM F874-1998(2014) Standard Test Method for Temperature Measurement and Profiling for Microwave Susceptors《微波感受器温度测量及外形图绘制的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F874-1998(2014) Standard Test Method for Temperature Measurement and Profiling for Microwave Susceptors《微波感受器温度测量及外形图绘制的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F874 98 (Reapproved 2014)Standard Test Method forTemperature Measurement and Profiling for MicrowaveSusceptors1This standard is issued under the fixed designation F874; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, t
2、he year of last revision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This is a test method for measuring surface temperaturesattained by microwave interactive packaging and coo
3、king aids(that is, susceptors). It is useful for measuring susceptor/foodinterface temperatures during microwave preparation of foodswith susceptor-based packaging, heating pads, and crispingsleeves, etc. It may also be used to measure the temperature ofa susceptor exposed to extractives testing or
4、in a liquidextraction cell to be used for nonvolatile extractives testing.The latter procedures are performed to establish test conditionsfor conducting extraction and migration studies using tempera-ture versus time profiles approximating those for actual micro-wave preparation of the product.1.1.1
5、 Several of the steps of this test method are takendirectly from Test Method F1308 which gives extractiontesting procedures for susceptors.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard does not purport to
6、 address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F1308 Tes
7、t Method for Quantitating Volatile Extractables inMicrowave Susceptors Used for Food ProductsF1317 Test Method for Calibration of Microwave OvensF1349 Test Method for Nonvolatile Ultraviolet (UV) Ab-sorbing Extractables from Microwave SusceptorsF1500 Test Method for Quantitating Non-UV-AbsorbingNonv
8、olatile Extractables from Microwave Susceptors Uti-lizing Solvents as Food Simulants3. Apparatus3.1 Microwave Oven, no turntable, unmodified except forsmall holes to allow for probe lead access to the oven cavity.The oven should be calibrated in accordance with Test MethodF1317.3.2 Fluoroptic Thermo
9、metry System .3.3 Vials, headspace, 20 mL.3.4 Septa, polytetrafluorethylene (PTFE) polymer faced sili-cone rubber.3.5 Vial Crimp Caps.3.6 Microwave Nonvolatile Extraction CellThis cell mustbe constructed of PTFE-fluorocarbon polymer. Additionaldetails on this cell may be found in Test Method F1349.3
10、.7 Beakers, 600 and 250 mL, or other sizes as appropriate.3.8 Aluminum Foil, household roll.3.9 Adhesive Tape, such as Kapton high-temperature tape,vinyl tape, silicone tape, etc.3.10 High-Vacuum Silicone Grease .3.11 Syringe Needle, 13 gage diameter.3.12 Corn Oil, Miglyol 812 (a fractionated coconu
11、t oil), orsynthetic fat simulant HB 307. See Test Method F1349 fordetails.3.13 Petri Dishes.3.14 Fan, tabletop.3.15 Blue Ice.3.16 Vials, for alternative profile method, 40-mL clear vials.3.17 Screw Caps.4. Procedure4.1 General:4.1.1 Start all tests with a cool microwave oven, that is,ambient tempera
12、ture. Use a fan and blue ice to cool oven floor1This test method is under the jurisdiction of ASTM Committee F02 on FlexibleBarrier Packaging and is the direct responsibility of Subcommittee F02.15 onChemical/Safety Properties.Current edition approved April 1, 2014. Published April 2014. Originallya
13、pproved in 1990. Last previous edition approved in 2008 as F874 98(2008). DOI:10.1520/F0874-98R14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Docu
14、ment Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1or any other reliable method to suitably return the oven toambient temperature between replicates.4.1.2 Test three replicates per variable.5. Measure
15、ment of Food/Susceptor InterfaceTemperature During Microwave Cooking5.1 Place product in center of the microwave oven as aconsumer would. Mark the position of first replicate on ovenfloor, and position subsequent replicates similarly.5.2 Position probes at food susceptor interface in such amanner th
16、at good probe/susceptor contact is maintained duringcooking, disturbing the food load as little as possible. Theanalyst may wish to position multiple probes on differentregions of the susceptor, such as the center and edge, as thetemperature attained at different locations may differ signifi-cantly.
17、5.2.1 If the nature of the product permits, the analyst maywish to determine whether probes positioned parallel to thesusceptor surface, or abutted to the susceptor surface wouldresult in better temperature measurement as evidenced bybetter reproducibility between replicate runs and lessdiscontinuit
18、y, due to loss of contact, of temperature readingsversus time.5.3 For in-package measurements for products such asmicrowave popcorn, probe access into the package is achievedby drilling approximately 0.1-in. holes through the package.(See Fig. 1 for probe placement inside a popcorn bag.) It is alsoa
19、dvisable to route the probes along the bottom of the packageto avoid disruption of probe/susceptor contact as the bagexpands during cooking. If it has been demonstrated that theouter bag surface and inner bag surface temperatures areequivalent, then taping the probes to the outer surface would besat
20、isfactory.5.4 For products prepared on a susceptor board, such asmicrowave pizza, the probe should be immobilized to thesusceptor board in parallel contact by applying a suitableadhesive tape 0.5 in. behind the probe tip.5.5 For products without free fat or oil at the food susceptorinterface, it is
21、advisable to apply high-vacuum silicone greaseto the tip of the probe to assure good thermal contact with thesusceptor.5.6 Microwave at full power for the maximum directedcooking time of the product, recording the temperature of eachprobe, preferably at 5-s intervals, but at intervals not to exceed1
22、5 s. It is suggested that readings be taken at 1-s intervals ifpossible, in order to generate a smoother curve. Calculate theaverage of the replicate runs at each recorded time for eachprobe position. Do not use data if discontinuities appear in plot(indicative of loss of susceptor/probe contact).6.
23、 Temperature Profiling of Susceptors in Vials Used forVolatile Extractives Testing6.1 First determine the temperature versus time profile forthe product during microwave preparation in accordance withSection 5.6.2 Cut a 10 by 65-mm (6.5 cm2or 1-in.2) portion from thesusceptor sample to be tested. In
24、sert carefully into vial,positioning the sample on the vial side, with the active sidefacing into the vial.6.3 Using a 13-gage syringe needle, pierce a hole into aseptum, place septum on vial and crimp.6.4 Insert one temperaturesensing probe through the sep-tum hole into the vial and manipulate it u
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF87419982014STANDARDTESTMETHODFORTEMPERATUREMEASUREMENTANDPROFILINGFORMICROWAVESUSCEPTORS 微波 感受器

链接地址:http://www.mydoc123.com/p-537435.html