ASTM F874-1998(2003) Standard Test Method for Temperature Measurement and Profiling for Microwave Susceptors《微波感受器温度测量及外形图绘制的方法》.pdf
《ASTM F874-1998(2003) Standard Test Method for Temperature Measurement and Profiling for Microwave Susceptors《微波感受器温度测量及外形图绘制的方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F874-1998(2003) Standard Test Method for Temperature Measurement and Profiling for Microwave Susceptors《微波感受器温度测量及外形图绘制的方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 874 98 (Reapproved 2003)Standard Test Method forTemperature Measurement and Profiling for MicrowaveSusceptors1This standard is issued under the fixed designation F 874; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、 the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This is a test method for measuring surface temperaturesattained by microwave interactive packaging and
3、cooking aids(that is, susceptors). It is useful for measuring susceptor/foodinterface temperatures during microwave preparation of foodswith susceptor-based packaging, heating pads, and crispingsleeves, etc. It may also be used to measure the temperature ofa susceptor exposed to extractives testing
4、or in a liquidextraction cell to be used for nonvolatile extractives testing.The latter procedures are performed to establish test conditionsfor conducting extraction and migration studies using tempera-ture versus time profiles approximating those for actual micro-wave preparation of the product.1.
5、1.1 Several of the steps of this test method are takendirectly from Test Method F 1308 which gives extractiontesting procedures for susceptors.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standar
6、d to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F 1308 Test Method for Quantitating Volatile Extractablesin Microwave Susceptors Used for Food ProductsF 1317 Test Method for Cal
7、ibration of Microwave OvensF 1349 Test Method for Nonvolatile Ultraviolet (UV) Ab-sorbing Extractables from Microwave SusceptorsF 1500 Test Method for Quantitating Non-UV-AbsorbingNonvolatile Extractables from Microwave Susceptors Uti-lizing Solvents as Food Simulants3. Apparatus3.1 Microwave Oven,
8、no turntable, unmodified except forsmall holes to allow for probe lead access to the oven cavity.The oven should be calibrated in accordance with Test MethodF 1317.3.2 Fluoroptic Thermometry System.33.3 Vials, headspace, 20 mL.43.4 Septa, polytetrafluorethylene (PTFE) polymer faced sili-cone rubber.
9、53.5 Vial Crimp Caps.63.6 Microwave Nonvolatile Extraction Cell7This cellmust be constructed of PTFE-fluorocarbon polymer.8Addi-tional details on this cell may be found in Test Method F 1349.3.7 Beakers, 600 and 250 mL, or other sizes as appropriate.3.8 Aluminum Foil, household roll.3.9 Adhesive Tap
10、e, such as Kapton high-temperature tape,vinyl tape, silicone tape, etc.93.10 High-Vacuum Silicone Grease.103.11 Syringe Needle, 13 gage diameter.3.12 Corn Oil, Miglyol 812 (a fractionated coconut oil), orsynthetic fat simulant HB 307. See Test Method F 1349 fordetails.3.13 Petri Dishes.1This test me
11、thod is under the jurisdiction of ASTM Committee F02 on FlexibleBarrier Materials and is the direct responsibility of Subcommittee F02.15 onChemical/Safety Properties.Current edition approved Oct. 10, 1998. Published March 1999. Originallypublished as F 874 90. Last previous edition F 874 91.2For re
12、ferenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Luxtron Model 750 or equivalent, with Luxtron MIH or MIW temperatur
13、eprobes, or equivalent. Available from Luxtron Inc., 106 Terra Bella Ave., MountainView, CA 90403.4Available from Shamrock Glass Co., 200 N. DelawareAve., Seaford, DE 19973(Catalog No. 667601) or Chemical Research Supplies, PO Box 888, Addison, IL60101 (Catalog No. 237502), or equivalent.5Available
14、from Shamrock Glass Co. (Catalog No. 778173A) or HewlettPackard (Catalog No. 5080-8726), or equivalent.6Available from Shamrock Glass Co. (Catalog No. 778704) or Hewlett PackardComputer Supplies Operation, PO Box 62124, San Francisco, CA 94162 (CatalogNo. 07675-20625), or equivalent.7Available from
15、Waldorf Corp., 2250 Wabash Ave., St. Paul, MN 55114.8PTFE-fluorocarbon polymer materials may be purchased from Read Plastics,Rockville, MD, or equivalent.9Available from Curtin Mattheson Scientific (Catalog No. 301-911).10Available from Curtin Mattheson Scientific (Catalog No. 218-636).1Copyright AS
16、TM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.14 Fan, tabletop.3.15 Blue Ice.3.16 Vials, for alternative profile method, 40-mL clearvials.113.17 Screw Caps.124. Procedure4.1 General:4.1.1 Start all tests with a cool microwave oven, that is,am
17、bient temperature. Use a fan and blue ice to cool oven flooror any other reliable method to suitably return the oven toambient temperature between replicates.4.1.2 Test three replicates per variable.5. Measurement of Food/Susceptor InterfaceTemperature During Microwave Cooking5.1 Place product in ce
18、nter of the microwave oven as aconsumer would. Mark the position of first replicate on ovenfloor, and position subsequent replicates similarly.5.2 Position probes at food susceptor interface in such amanner that good probe/susceptor contact is maintained duringcooking, disturbing the food load as li
19、ttle as possible. Theanalyst may wish to position multiple probes on differentregions of the susceptor, such as the center and edge, as thetemperature attained at different locations may differ signifi-cantly.5.2.1 If the nature of the product permits, the analyst maywish to determine whether probes
20、 positioned parallel to thesusceptor surface, or abutted to the susceptor surface wouldresult in better temperature measurement as evidenced bybetter reproducibility between replicate runs and less discon-tinuity, due to loss of contact, of temperature readings versustime.5.3 For in-package measurem
21、ents for products such asmicrowave popcorn, probe access into the package is achievedby drilling approximately 0.1-in. holes through the package.(See Fig. 1 for probe placement inside a popcorn bag.) It is alsoadvisable to route the probes along the bottom of the packageto avoid disruption of probe/
22、susceptor contact as the bagexpands during cooking. If it has been demonstrated that theouter bag surface and inner bag surface temperatures areequivalent, then taping the probes to the outer surface would besatisfactory.5.4 For products prepared on a susceptor board, such asmicrowave pizza, the pro
23、be should be immobilized to thesusceptor board in parallel contact by applying a suitableadhesive tape 0.5 in. behind the probe tip.5.5 For products without free fat or oil at the food susceptorinterface, it is advisable to apply high-vacuum silicone greaseto the tip of the probe to assure good ther
24、mal contact with thesusceptor.5.6 Microwave at full power for the maximum directedcooking time of the product, recording the temperature of eachprobe, preferably at 5-s intervals, but at intervals not to exceed15 s. It is suggested that readings be taken at 1-s intervals ifpossible, in order to gene
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF87419982003STANDARDTESTMETHODFORTEMPERATUREMEASUREMENTANDPROFILINGFORMICROWAVESUSCEPTORS 微波 感受器

链接地址:http://www.mydoc123.com/p-537433.html