ASTM F856-1997(2018) Standard Practice for Mechanical Symbols Shipboard&x2014 Heating Ventilation and Air Conditioning (HVAC).pdf
《ASTM F856-1997(2018) Standard Practice for Mechanical Symbols Shipboard&x2014 Heating Ventilation and Air Conditioning (HVAC).pdf》由会员分享,可在线阅读,更多相关《ASTM F856-1997(2018) Standard Practice for Mechanical Symbols Shipboard&x2014 Heating Ventilation and Air Conditioning (HVAC).pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F856 97 (Reapproved 2018) An American National StandardStandard Practice forMechanical Symbols, ShipboardHeating, Ventilation, andAir Conditioning (HVAC)1This standard is issued under the fixed designation F856; the number immediately following the designation indicates the year of orig
2、inaladoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department o
3、f Defense.1. Scope1.1 This practice covers symbols used on heating,ventilation, and air conditioning (HVAC) detailed engineeringdrawings.1.2 These symbols may be useful on contract and prelimi-nary design drawings.1.3 This international standard was developed in accor-dance with internationally reco
4、gnized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Significance and Use2.1 When symbolic representation is requ
5、ired for an itemnot covered in this standard, the character of the symbol shallbe adequately identified and shall be subject to one interpreta-tion only. If necessary, a note shall be attached to the symbolfor further clarity.2.2 Symbolic representation does not require exact or scalelayouts of the
6、actual system. Therefore, the symbols may beused in all views of the system layout.3. Abbreviations3.1 The abbreviations (for use only in this practice) aredefined as follows:AF = axial fanAFD = automatic fire damper with manual overrideBD = balance damperCC = cooling coilCCW = counter clockwiseCE =
7、 convection heater, electricCF = centrifugal fanCS = convection heater, steamCW = clockwiseEH = turret heater, electricEP = duct preheater, electricER = duct reheater, electricEU = electric unit heaterF = filterFA = flame arresterFCA = fan coil assemblyFCU = fan coil unitG = grilleGC = gravity cooli
8、ng coilH = humidistat, humidifierL = louverM = motorMFD = manual fire damperNE = natural exhaustNS = natural supplyR = return airRO = remote operatedSFD = solenoid fire damperSP = preheater, steamSR = reheater, steamSU = steam unit heaterT = thermostatTE = tempered air, electricTS = tempered air, st
9、eamU = undercutUC = unit coolerV = volume, volumetricVC = volume control4. Illustrations4.1 Illustrations for HVAC symbols are given in Figs. 1-4.5. Keywords5.1 air conditioning; design symbols; engineering symbols;heating; HVAC; marine; ship; symbols; ventilation1This practice is under the jurisdic
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF85619972018STANDARDPRACTICEFORMECHANICALSYMBOLSSHIPBOARDX2014HEATINGVENTILATIONANDAIRCONDITIONINGHVACPDF

链接地址:http://www.mydoc123.com/p-537408.html