《ASTM F856-1997(2004) Standard Practice for Mechanical Symbols Shipboard&8212 Heating Ventilation and Air Conditioning (HVAC)《加热、通风及空调符号》.pdf》由会员分享,可在线阅读,更多相关《ASTM F856-1997(2004) Standard Practice for Mechanical Symbols Shipboard&8212 Heating Ventilation and Air Conditioning (HVAC)《加热、通风及空调符号》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 856 97 (Reapproved 2004)An American National StandardStandard Practice forMechanical Symbols, ShipboardHeating, Ventilation, andAir Conditioning (HVAC)1This standard is issued under the fixed designation F 856; the number immediately following the designation indicates the year oforig
2、inal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of D
3、efense.1. Scope1.1 This practice covers symbols used on heating, ventila-tion, and air conditioning (HVAC) detailed engineering draw-ings.1.2 These symbols may be useful on contract and prelimi-nary design drawings.2. Significance and Use2.1 When symbolic representation is required for an itemnot co
4、vered in this standard, the character of the symbol shallbe adequately identified and shall be subject to one interpreta-tion only. If necessary, a note shall be attached to the symbolfor further clarity.2.2 Symbolic representation does not require exact or scalelayouts of the actual system. Therefo
5、re, the symbols may beused in all views of the system layout.3. Abbreviations3.1 The abbreviations (for use only in this practice) aredefined as follows:AF = axial fan,AFD = automatic fire damper with manual override,BD = balance damper,CC = cooling coil,CCW = counter clockwise,CE = convection heate
6、r, electric,CF = centrifugal fan,CS = convection heater, steam,CW = clockwise,EH = turret heater electric,EP = duct preheater, electric,ER = duct reheater, electric,EU = electric unit heater,F = filter,FA = flame arrester,FCA = fan coil assembly,FCU = fan coil unit,G = grille,GC = gravity cooling co
7、il,H = humidistat, humidifier,L = louver,M = motor,MFD = manual fire damper,NE = natural exhaust,NS = natural supply,R = return air,RO = remote operated,SFD = solenoid fire damper,SP = preheater, steam,SR = reheater, steam,SU = steam unit heater,T = thermostat,TE = tempered air, electric,TS = temper
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF85619972004STANDARDPRACTICEFORMECHANICALSYMBOLSSHIPBOARD8212HEATINGVENTILATIONANDAIRCONDITIONINGHVAC

链接地址:http://www.mydoc123.com/p-537405.html