ASTM F819-2010 Standard Terminology Relating to Electrical Protective Equipment for Workers《工人用电气防护装备相关标准术语》.pdf
《ASTM F819-2010 Standard Terminology Relating to Electrical Protective Equipment for Workers《工人用电气防护装备相关标准术语》.pdf》由会员分享,可在线阅读,更多相关《ASTM F819-2010 Standard Terminology Relating to Electrical Protective Equipment for Workers《工人用电气防护装备相关标准术语》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F819 10Standard TerminologyRelating to Electrical Protective Equipment for Workers1This standard is issued under the fixed designation F819; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last revision. A
2、number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Referenced Documents1.1 ASTM Standards:2F712 Test Methods and Specifications for Electrically Insu-lating Plastic Guard Equipment for Protection
3、 of WorkersF1116 Test Method for Determining Dielectric Strength ofDielectric FootwearF1117 Specification for Dielectric Footwear2. Terminologyafterflame time, nthe length of time in seconds for which amaterial continues to flame after the ignition source has beenremovedDISCUSSIONIn arc testing, the
4、 length of time for which a specimencontinues to exhibit a visible flaming as determined by a time displayvideo recording of the specimen during arc testingarc duration, ntime duration of the arc(s).arc energy (vi dt), nsum of the instantaneous arc voltagevalues multiplied by the instantaneous arc c
5、urrent valuesmultiplied by the incremental time values during the arc, (J).arc gapdistance between the arc electrodes (inch).Arc thermal performance value (ATPV), nin arc testing,the incident energy on a fabric or material that results in a50 % probability that sufficient heat transfer through thete
6、sted specimen is predicted to cause the onset of a second-degree skin burn injury based on the Stoll curvearc voltage, nvoltage across the gap caused by the currentflowing through the resistance created by the arc gap, V.asymmetrical arc current, nthe total arc current producedduring closure; it inc
7、ludes a direct component and a sym-metrical component, A.blanket roll-upa container made from fabric or similarmaterial and specifically designed to protect the blanket fromdamage during storage or transportation.blowout, nthe extinguishing of the arc caused by a magneticfield.breakdown, electricalt
8、he electrical discharge or arc occur-ring between the electrodes and through the equipment beingtested.bulk storagethe storage of hose or covers together with oneor more layers piled neatly, but without the benefit ofspacers, supports, or special protective containers.charring, nthe formation of car
9、bonaceous residue as theresult of pyrolysis or incomplete combustion.closure, npoint on supply current wave form where arc isinitiated.color splasha splash, smear, or streak of contrasting colorevident on the inside or outside surface of the gloves orsleeves that was deposited during the dipping ope
10、ration andis vulcanized into the material as part of the patiblenot injurious to or changing the physical orelectrical characteristics of the blankets or affecting theirapplication, use, or acceptability.coveran electrically insulated enclosure designed to beinstalled temporarily on various types of
11、 irregularly shapedelectrical equipment to protect personnel and equipmentworking in close proximity.designated personan individual who is qualified by expe-rience or training to perform an assigned task.distortedphysically changed from the natural and originalshape, caused by stress of any type.ele
12、ctrical testing facilitya location with qualified personnel,testing equipment, and procedures for the inspection andelectrical testing of electrical insulating protective equip-ment.electrodethe energized or grounded conductor portion ofelectrical test equipment which is placed near or in contactwit
13、h the material or equipment being tested.electrode clearancethe shortest path from the energizedelectrode to the ground electrode.embrittlement, nthe formation of a brittle residue as theresult of pyrolysis or incomplete combustion.flashoverthe electrical discharge or arc occurring betweenelectrodes
14、 and over or around, but not through, the equip-ment being tested.1These definitions are under the jurisdiction of ASTM Committee F18 onElectrical Protective Equipment for Workers and are the direct responsibility ofSubcommittee F18.60 on Terminology.Current edition approved April 1, 2010. Published
15、 May 2010. Originallyapproved in 1995. Last previous edition approved in 2008 as F819-08. DOI:10.1520/F0819-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the s
16、tandards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.foot portionthe portion of the footwear below the wearersankle bone.FRP insulating tubes and rodsfiberglass reinforced plastic(FRP) pro
17、ducts manufactured so that the tubes and rodsproduced will meet the electrical and mechanical require-ments in the standard.gauntletthe area of a glove between the wrist and thereinforced edge of the opening.halogenation treatmentexposure of the entire rubber sur-face area to a halogen for the purpo
18、se of reducing surfacefriction.heat attenuation factor HAF, nin electric arc testing, thepercent of the incident energy which is blocked by a materialat an incident energy level equal to ATPV.heat flux, nthe thermal intensity indicated by the amount ofenergy transmitted divided by area and time kW/m
19、2(cal/cm2s).hosean electrical insulating tube with a longitudinal slitdesigned to be installed temporarily on energized electricalwires.i2t, nsum of the instantaneous arc current values squaredmultiplied by the incremental time values during the arc(A2s).ignition, nthe initiation of combustion.incid
20、ent energy (Ei), nthe amount of energy (total heat,cal/cm2) received at a surface as a direct result of an electricarc discharge as measured by temperature rise on coppercalorimeters.insulatedseparated from other conducting surfaces by adielectric substance (including air space) offering a highresis
21、tance to the passage of current.DISCUSSIONWhen any object is said to be insulated, it is understoodto be insulated in a suitable manner for the conditions to which it issubjected. Otherwise, it is, within the purpose of this definition,uninsulated. Insulating covering of conductors is one means of m
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF8192010STANDARDTERMINOLOGYRELATINGTOELECTRICALPROTECTIVEEQUIPMENTFORWORKERS 工人 用电 防护 装备 相关 标准 术语

链接地址:http://www.mydoc123.com/p-537323.html