ASTM F567-2007 Standard Practice for Installation of Chain-Link Fence《链节栅栏的安装用标准实施规程》.pdf
《ASTM F567-2007 Standard Practice for Installation of Chain-Link Fence《链节栅栏的安装用标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F567-2007 Standard Practice for Installation of Chain-Link Fence《链节栅栏的安装用标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 567 07Standard Practice forInstallation of Chain-Link Fence1This standard is issued under the fixed designation F 567; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parenthese
2、s indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the installation procedure for chain-link fence.1.2 This practice is intended primarily to guide thoseresponsible for or concerned wi
3、th the installation of chain-linkfence.1.3 This practice does not intend to preclude any practicethat has proven equal to or given better performance undervarying conditions, that is, location, weather, intended use,materials, etc.1.4 This standard does not purport to address all of thesafety proble
4、ms, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificprecautionary statements, see Section 13.2. Referenced Documents2.1 AST
5、M Standards:2F 626 Specification for Fence FittingsF 654 Specification for Residential Chain Link Fence GatesF 900 Specification for Industrial and Commercial SwingGatesF 1184 Specification for Industrial and Commercial Hori-zontal Slide Gates3. Site Preparation3.1 The purchaser shall indicate the l
6、ocation of fence lines,gates, and terminal posts with suitable stakes. Stake intervalsshall not exceed 500 ft 152.5 m or line of sight.3.2 All underground utility locations, USC that is, under normal conditions thediameter shall be four times the largest cross section of the postup to a 4 in. 101.5
7、mm outside diameter and three times forlarger outside diameters. The depth shall be a minimum of 24in. 609.6 mm plus an additional 3 in. 76.2 mm for each 1-ft305-mm increase in the fence height over 4 ft 1.22 m to amaximum total of 60 in. 1525 mm for a fence height up to 20ft. 6.10 m.5.2 Dig or dril
8、l holes in the line of the fence in accordancewith 5.1. Forms are not necessary.5.3 Set posts in a vertical position, plumb and in line.Backfill concrete (2500 psi) 17.2 MPa into the excavationand extend 2 in. 50 mm above grade. An alternative methodis to stop footing 6 in. 152.4 mm below grade to a
9、llow forcover with sod, black top, or other materials if the footings arenot in an area subject to cathodic protection. In either case,crown the concrete at its top to shed water and slope aminimum of 2 in. 50.8 mm away from the post.5.4 The use of mechanical devices for the setting of fenceposts is
10、 acceptable under this practice, provided the mechanicalstrength in the ground is equal or superior to the strengthdeveloped by the concrete footing as recommended.5.5 When solid rock or concrete is encountered, without anoverburden of soil, set posts in the solid rock or concrete. Thedepth of the h
11、ole shall be three times the largest cross sectionof the posts. The diameter of the hole shall be12 in. 13 mmgreater than the largest cross section of the post.1This practice is under the jurisdiction of ASTM Committee F14 on Fences andis the direct responsibility of Subcommittee F14.40 on Chain Lin
12、k Fence and WireAccessories.Current edition approved July 1, 2007. Published July 2007. Originally approvedin 1978. Last previous edition approved in 2000 as F 567 - 00.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annua
13、l Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.6 The use of sleeves in order to leave voids in newconcrete construction is
14、 recommended.5.7 Half-fill the void with nonshrinkable hydraulic cementand force post to the bottom of the hole and plumb. Thoroughlywork additional grout into the hole so as to leave no voids.Crown the grout to shed water.5.8 Drive posts are to be driven by mechanical means to aminimum depth of 36
15、in. 914.4 mm or 6 in. 152.4 mmgreater than that called for in 5.1, for the height of fence.5.9 Where soil conditions are unstable or rock is encoun-tered, the drive post embedment must be altered to maintainstability. The depth should be in keeping with standard fenceconstruction practices for the l
16、ocal area or refer to 5.5.5.10 The post tops must be protected to prevent distortion ofthe exposed end. The use of a drive cap is recommended.5.11 Residential Swing Gate Posts:5.11.1 See Table 1.5.12 Industrial and Commercial Swing Gate Posts:5.12.1 See Table 2.5.13 Cantilever Slide Gate Posts (Spec
17、ification F 1184,Type II)Refer to Specification F 1184, Type II CantileverSlide Gates, for post setting requirements.5.14 Overhead Slide Gate Posts (Specification F 1184, TypeI)Refer to Specification F 1184, Type I Overhead SlideGates, for post setting requirements.6. Terminal Post Bracing6.1 No bra
18、ces are required on fabric 6 ft 1.83 m high orless where the top rail is specified. On all fabric over 6 ft,braces are required. On fabric over 12 ft 3.66 m in height, acenter rail is required; regardless of height, all fences installedwithout a top rail shall have braces on all terminals.6.2 Secure
19、ly fasten diagonal braces to the terminal post andthe adjacent line post or its footing or a footing of equal size.There shall be no more than a 50 angle between the brace andthe ground. Securely fasten horizontal braces with truss rods tothe adjacent line post and terminal posts.6.3 When the top ra
20、il is used, attach the brace at the halfwaypoint of the terminal post above grade and, when the top rail isomitted, at the two-thirds point above grade.7. Top Rail and Tension Wire7.1 Support the top rail at each post so that a continuousbrace from end to end of each stretch of fence is formed.Secur
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF5672007STANDARDPRACTICEFORINSTALLATIONOFCHAINLINKFENCE 栅栏 安装 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-536897.html