ASTM F481-1997(2008) Standard Practice for Installation of Thermoplastic Pipe and Corrugated Pipe in Septic Tank Leach Fields《化粪池沥虑场用热塑性管道和波纹软管的安装标准实施规程》.pdf
《ASTM F481-1997(2008) Standard Practice for Installation of Thermoplastic Pipe and Corrugated Pipe in Septic Tank Leach Fields《化粪池沥虑场用热塑性管道和波纹软管的安装标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F481-1997(2008) Standard Practice for Installation of Thermoplastic Pipe and Corrugated Pipe in Septic Tank Leach Fields《化粪池沥虑场用热塑性管道和波纹软管的安装标准实施规程》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 481 97 (Reapproved 2008)An American National StandardStandard Practice forInstallation of Thermoplastic Pipe and Corrugated Pipe inSeptic Tank Leach Fields1This standard is issued under the fixed designation F 481; the number immediately following the designation indicates the year of
2、original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice describes procedures for handling andinstalli
3、ng thermoplastic pipe and corrugated pipe in septic tankleach fields, curtain drains, and from the septic tank to the leachfield. Proper installation ensures that the pipe will satisfactorilyconvey and distribute partially treated waste water to aleaching field for additional treatment and disposal
4、by soilabsorption. The curtain or perimeter drain will function toprotect the soil absorption capacity of the leach field.1.2 To ensure compliance with local regulatory provisions,the local approving authority (local health departments and soforth) should be contacted regarding specific requirements
5、 forleach field design materials and installation.1.3 This practice applies to pipe and fittings made undereach of the following ASTM specifications:1.3.1 For transport from tank to leach field: SpecificationsD 2680, D 2729, D 2751, D 2852, D 3034, F 405, F 758,F 789, F 810, F 891, F 892, and F 949.
6、1.3.2 Perforated, for use in leach field or curtain drain:Specifications D 2729, D 2751, F 405, F 810, F 891, andF 892.1.4 Pipe intended for installation in accordance with thispractice should have a minimum pipe stiffness as specified inthe appropriate product standard referenced in 1.3.1 or 1.3.2.
7、1.5 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.6 This standard does not purport to address all of thesafety concerns, if any, asso
8、ciated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificprecautionary statements, see Section 7.2. Referenced Documents2.1 ASTM Standards:2D 16
9、00 Terminology for Abbreviated Terms Relating toPlasticsD 2321 Practice for Underground Installation of Thermo-plastic Pipe for Sewers and Other Gravity-Flow Applica-tionsD 2680 Specification for Acrylonitrile-Butadiene-Styrene(ABS) and Poly(Vinyl Chloride) (PVC) Composite SewerPipingD 2729 Specific
10、ation for Poly(Vinyl Chloride) (PVC)Sewer Pipe and FittingsD 2751 Specification for Acrylonitrile-Butadiene-Styrene(ABS) Sewer Pipe and FittingsD 2852 Specification for Styrene-Rubber (SR) Plastic DrainPipe and FittingsD 3034 Specification for Type PSM Poly(Vinyl Chloride)(PVC) Sewer Pipe and Fittin
11、gsF 405 Specification for Corrugated Polyethylene (PE) Pipeand FittingsF 412 Terminology Relating to Plastic Piping SystemsF 449 Practice for Subsurface Installation of CorrugatedPolyethylene Pipe forAgricultural Drainage or Water TableControlF 758 Specification for Smooth-Wall Poly(Vinyl Chloride)(
12、PVC) Plastic Underdrain Systems for Highway, Airport,and Similar DrainageF 789 Specification for Type PS-46 and Type PS-115 Poly-(Vinyl Chloride) (PVC) Plastic Gravity Flow Sewer Pipeand Fittings3F 810 Specification for Smoothwall Polyethylene (PE) Pipefor Use in Drainage and Waste Disposal Absorpti
13、on FieldsF 891 Specification for Coextruded Poly(Vinyl Chloride)(PVC) Plastic Pipe With a Cellular Core1This practice is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.65 on LandDrainage.Current edition approved July 1, 2008
14、. Published August 2008. Originallyapproved in 1976. Last previous edition approved in 2002 as F 481 97(2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the st
15、andards Document Summary page onthe ASTM website.3Withdrawn.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.F 892 Specification for Polyethylene (PE) Corrugated PipeWith a Smooth Interior and Fittings3F 949 Specification for Poly(Vin
16、yl Chloride) (PVC) Corru-gated Sewer Pipe With a Smooth Interior and Fittings3. Terminology3.1 Definitions are in accordance with Terminology F 412and abbreviations are in accordance with Terminology D 1600,unless otherwise specified.3.2 Definitions of Terms Specific to This Standard:3.2.1 dual-wall
17、 pipepipe with corrugated exterior andsmooth interior.3.2.2 pipesmooth or corrugated interior wall thermoplas-tic pipe.4. General Requirements4.1 StoragePipe should be stored with support from a flatsurface to prevent the pipe from developing a permanent set.4.2 HandlingCare should be exercised duri
18、ng loading,unloading, and in transit because pipe may be damaged byabrasion and sharp edges. Because thermoplastics are tempo-rarily softened by high temperatures, care should be takenunder these conditions to avoid damage during handlingoperations.4.3 If contact with chemicals not ordinarily presen
19、t insanitary sewage is anticipated, the approval of the regulatoryauthority to install pipe should be obtained.NOTE 1The manufacturer should be contacted for information onchemical resistance.4.4 Coiled pipe is not recommended for use in leach fieldsbecause it is difficult to install at the proper g
20、rade andalignment; it is acceptable with special equipment installation.NOTE 2Corrugated interior pipe should not be used between thedwelling and the waste water treatment unit (septic tank or similar device)because the corrugations may inhibit the flow of solids contained in thewaste.5. Installatio
21、nLeach Field5.1 Leach fields should be constructed to meet the require-ments of the local Department of Health or other governingauthority, which should be contacted for information andrequirements on design, location, installation, materials, and soforth.5.2 Before installation, pipe should be insp
22、ected for damagesuch as kinks, crushed portions, splits, and so forth. Anydamaged portions of pipe shall be cut out as a cylinder anddiscarded. Make a visual check of the bore to ensure it is clearof foreign objects that might impede flow.5.3 Gravel SystemsFor proper waste water flow into thesurroun
23、ding soils and to provide for support of pipe, a uniformlayer of 4 to 6 in. (100 to 150 mm) of graded aggregate shouldbe placed in the trench bottom and leveled true to grade priorto laying the pipe (see Fig. 1). Aggregate should range from34to 214 in. (13 to 54 mm) in size. The aggregate under the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF48119972008STANDARDPRACTICEFORINSTALLATIONOFTHERMOPLASTICPIPEANDCORRUGATEDPIPEINSEPTICTANKLEACHFIELDS

链接地址:http://www.mydoc123.com/p-536759.html