《ASTM F410-2008 Standard Test Method for Wear Layer Thickness of Resilient Floor Coverings by Optical Measurement《光学测量法对弹性地板覆盖物磨损层厚度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F410-2008 Standard Test Method for Wear Layer Thickness of Resilient Floor Coverings by Optical Measurement《光学测量法对弹性地板覆盖物磨损层厚度的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 410 08Standard Test Method forWear Layer Thickness of Resilient Floor Coverings byOptical Measurement1This standard is issued under the fixed designation F 410; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the yea
2、r of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers the det
3、ermination of the thick-ness of the wear layer of resilient non-textile floor coverings, intile or sheet form, with or without felt backing or foam layer,by optical measurement.1.2 This test method is applicable for wear layers with aminimum thickness of 0.0004 in. (0.01 mm) to a maximumthickness of
4、 0.1 in. (2.54 mm), where measurements within0.0001 in. or 0.0025 mm are tolerable.1.3 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.4 This standard does not purport to address all of thesafety concerns, if any, ass
5、ociated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 691 Practice for Conducting an Interlaboratory Study t
6、oDetermine the Precision of a Test Method3. Significance and Use3.1 This test method is applicable for wear layers with aminimum thickness of 0.001 in. (0.02 mm) to a maximumthickness of 0.1 in. (2.54 mm), where measurements within0.0005 in. or 0.01 mm are tolerable.4. Apparatus4.1 Compound Microsco
7、pe, having a magnification of atleast 403, equipped with an eyepiece micrometer of the ruleddisk or filar type. The scale shall cover approximately 0.1 in.(2.54 mm) and each division shall be equal to approximately0.0004 in. (0.01 mm) at the object. Either a binocular orstandard microscope may be us
8、ed.4.2 Vertical Illuminator (recommended), to illuminate thespecimen. If another source is used, the light should fall on thespecimen from as nearly vertical direction as possible.4.3 Stage Micrometer, for calibrating the eyepiece mi-crometer. The scale shall have the smallest division equal to0.000
9、4 in. (0.01 mm) and shall cover at least 0.1 in. (2.54 mm).The reference standard used for calibration shall be traceable toa National Standard.4.4 HolderA means for holding the specimen, withoutdistortion, so that the cut edge is perpendicular to the opticalaxis of the microscope.4.5 Sharp Knife, o
10、r razor blade in a holder, for cutting thespecimen.4.6 Cutting Board of plastic, hardboard or fine-grainedhardwood.4.7 Straightedge, for guiding the cutting edge.5. Test Specimen5.1 The specimen shall be cut from a properly selectedsample, representing the area to be measured. It shall beapproximate
11、ly 2 in. (50 mm) long on the edge to be measuredby about 0.5 in. (13 mm) in width.6. Procedure6.1 Preparation of SpecimenPlace the sample on thecutting board with the face side up. Hold the cutting instrumentso that the plane of the blade is perpendicular to the face of thesample. The cutting edge o
12、f the blade should be at an angle tothe horizontal that produces a clean cut. It is essential that thecut is perpendicular to the face of the sample. Apply sufficientpressure so that a clean cut can be made completely through thesample in one stroke, being careful not to distort the sample orturn th
13、e knife from the perpendicular. The cut should bestraight, and at least 2 in. (50 mm) long. Make a similar cutparallel to the first cut, about 0.5 in. (13 mm) apart. Cut eachend, so the specimen can be removed from the sample.6.2 Thickness Measurement:1This test method is under the jurisdiction ofAS
14、TM Committee F06 on ResilientFloor Coverings and is the direct responsibility of Subcommittee F06.20 on TestMethods - Products Construction/Materials.Current edition approved Feb. 1, 2008. Published March 2008. Originallyapproved in 1975. Last previous edition approved in 2002 as F 41002.2For refere
15、nced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West
16、Conshohocken, PA 19428-2959, United States.6.2.1 Mount the specimen with the long edge up, the cutsurface perpendicular to the optical axis of the microscope (seeAppendix X1).6.2.2 CalibrationCalibrate the eyepiece micrometeragainst the stage micrometer, and record the calibration factor.If a variab
17、le magnification (zoom) instrument, or one withadjustable tube length is used, be sure that these adjustmentsare not disturbed between calibration and measurement of thesample.6.2.3 Measurement with Ocular MicrometerLocate thespecimen under the microscope and adjust the light source.Focus the micros
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF4102008STANDARDTESTMETHODFORWEARLAYERTHICKNESSOFRESILIENTFLOORCOVERINGSBYOPTICALMEASUREMENT 光学 测量

链接地址:http://www.mydoc123.com/p-536601.html