1、Designation: F 2072 01 (Reapproved 2007)Standard Practice forHosedown of a Membrane Switch1This standard is issued under the fixed designation F 2072; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A num
2、ber in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice establishes procedures for the hosedown ofa membrane switch to verify adequate protection from ingressof water from a high-
3、volume water spray.1.2 This practice can also be used to verify the ability of amembrane switch or graphics layer to act as a liquid seal for afinished product.1.3 Additional test methods or practices can be incorporatedto investigate specific results or capabilities.1.4 This practice is a modificat
4、ion of NEMA PublicationNumber 250-1991 Section 6.7 which is a test for hosedown ofa finished product housing.2. Referenced Documents2.1 NEMA Publication 250-199123. Terminology3.1 Definitions:3.1.1 membrane switch, na momentary switching devicein which at least one contact is on, or made of, a flexi
5、blesubstrate.3.1.2 specified resistance, nmaximum allowable resis-tance as measured between two terminations whose internalswitch contacts, when held closed, complete a circuit.4. Significance and Use4.1 The presence of water inside a membrane switch canaffect its mechanical operation or electrical
6、functionality, orboth.4.2 This practice establishes a procedure to verify the abilityof a membrane switch to resist the entry of liquid into itself ora finished product, or both. It is useful in identifying designdeficiencies.4.3 Hosedown testing may be destructive, therefore anysamples tested shoul
7、d be considered unfit for future use.5. Interferences5.1 External VentingAny deliberate external venting ofthe switch will allow liquid to enter.5.2 Atmospheric PressureSignificant changes in atmo-spheric pressure during the test or at different facilities mayalter the time in which leakage might oc
8、cur.5.3 Duration of TestLonger exposure time increases thepossibility of leakage.5.4 Dye ColoringChoose a dye coloring that will notchemically attack the materials.6. Apparatus6.1 Water Supply, capable of delivering a stream of water ata rate of at least 65 gal/min through a 1 in. (25 mm) internaldi
9、ameter nozzle for the specified duration,6.2 An appropriate device or fixture to hold the switch in afixed position,6.3 Any additional equipment as required by other testmethods employed, and6.4 Nozzle with 1 in. (25 mm) internal diameter.7. Test Specimen7.1 The test specimen will be a membrane swit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF207220012007STANDARDPRACTICEFORHOSEDOWNOFAMEMBRANESWITCH 薄膜开关 软管 洗涤 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-536472.html