ASTM F2055-2000 Standard Test Method for Size and Squareness of Resilient Floor Tile by Dial Gage Method《测微仪法测定弹性地板砖尺寸和垂直度的标准试验方法》.pdf
《ASTM F2055-2000 Standard Test Method for Size and Squareness of Resilient Floor Tile by Dial Gage Method《测微仪法测定弹性地板砖尺寸和垂直度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2055-2000 Standard Test Method for Size and Squareness of Resilient Floor Tile by Dial Gage Method《测微仪法测定弹性地板砖尺寸和垂直度的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2055 00Standard Test Method forSize and Squareness of Resilient Floor Tile by Dial GageMethod1This standard is issued under the fixed designation F 2055; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of la
2、st revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of bothdimensions (length and width) and squareness of resilient floortile. T
3、his test method is intended for use with square tilesranging from a nominal 9 in. (226 mm) to 40 in. (1016 mm) indimension.1.2 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.3 This standard does not purport to addres
4、s all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:F 141 Terminology
5、 Relating to Resilient Floor Coverings2F 536 Test Method for Size of Resilient Floor Tile by DialGage Method2F 540 Test Method for Squareness of Resilient Floor Tile byDial Gage Method23. Significance and Use3.1 Both dimension and squareness of resilient floor tile areimportant considerations, becau
6、se installed flooring may ex-hibit an objectionable appearance when either or both charac-teristics deviate from established tolerances. This test methodprovides a means of determining actual dimensions and square-ness by using a single apparatus and procedure. This testmethod may be used as a subst
7、itute for Test Methods F 536 andF 540, which allow for similar measurements on resilient floortile up to 12 in. (305 mm) in size.4. Apparatus4.1 The apparatus shall consist of four dial gages (refer-enced A through D in Fig. 1) and two reference index stripsmounted on a flat bedplate in a configurat
8、ion that, by rotationof the sample, allows the measurement of all four sides ofresilient tile samples (see Fig. 1). One edge of the bedplate iselevated to create a test surface which is offset or tilted 15 61 degrees from horizontal. This offset applies minimal pressureto the test specimen against t
9、he longer index strip to ensurerepeatable measurement. A reference plate representing targettile size and squareness is used to zero all dial gages (see Fig.2).4.2 Dial GagesThe four dial gages are mounted in guideslots that are machined into the bedplate to allow for measure-ment of various tile si
10、zes while remaining within 10% of thecorner of the tile edge (for the two corner gages and onesquareness gage) or within the central 10% of the tile edge (forthe center gage only). Dial gages may report measurementsusing either electrical or mechanical means, but they shall begraduated to read 0.001
11、 in. (0.02 mm) and have a stem travelgreater than 0.25 in. (6 mm). The contact foot of the dial-gagestem shall be flat 0.500.75 6 0.001 in. (12.719.1 mm 6 0.2mm) in diameter and exert a total force of not more than 3.0 60.1 ozf (0.83 6 0.003 N). Dial gages shall be securelypositioned so that when th
12、e reference plate is in place, thecontact foot is extended approximately 50% of its full travel.4.3 Index StripsThe apparatus contains 2 fixed indexstrips. A horizontal index strip shall be mounted parallel to andjust inside the lower edge of the bedplate. It shall be 1.5 6 0.1in. (38 6 3 mm) greate
13、r in length and a minimum of twice thethickness of the largest tile to be tested. A second index stripshall be mounted 90 6 10 s (1.57080 6 0.00005 rad.) to the1This test method is under the jurisdiction of ASTM Committee F06 on ResilientFloor Coverings and is the direct responsibility of Subcommitt
14、e F06.20 on TestMethodsProducts Construction/Materials.Current edition approved Sept. 10, 2000. Published November 2000.2Annual Book of ASTM Standards, Vol 15.04.FIG. 1 Tile Measurement Apparatus1Copyright ASTM, 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959, United States.horizontal index
15、strip. The lower end of this index strip shall be0.125 6 0.01 in. (3.1 6 0.25 mm) above the right end of thehorizontal index strip and is used to locate one corner of thesample tile.4.4 Reference PlateThe reference plate shall be made tothe target dimensions of the manufactured tile. The length andw
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF20552000STANDARDTESTMETHODFORSIZEANDSQUARENESSOFRESILIENTFLOORTILEBYDIALGAGEMETHOD 测微仪法 测定 弹性 地板砖

链接地址:http://www.mydoc123.com/p-536422.html