《ASTM F2054-2007 Standard Test Method for Burst Testing of Flexible Package Seals Using Internal Air Pressurization Within Restraining Plates《在约束板中使用内部气体加压法做软包装密封件碎裂测试的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2054-2007 Standard Test Method for Burst Testing of Flexible Package Seals Using Internal Air Pressurization Within Restraining Plates《在约束板中使用内部气体加压法做软包装密封件碎裂测试的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 2054 07Standard Test Method forBurst Testing of Flexible Package Seals Using Internal AirPressurization Within Restraining Plates1This standard is issued under the fixed designation F 2054; the number immediately following the designation indicates the year oforiginal adoption or, in
2、the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the procedure for determiningthe minimum burst strength of
3、 a seal placed around theperimeter of a flexible package as it is internally pressurizedand enclosed within restraining plates.1.2 The test methods described herein are functionallysimilar to Test Methods F 1140 with the exception of the use ofrestraining plates. Test Methods F 1140 describes method
4、s ofburst testing that do not include the use of restraining platesand are suitable to determine a packages general ability towithstand pressurization stresses. Under Test Methods F 1140the stresses are not distributed uniformly to all areas of thepackage seal. Under unrestrained conditions the stre
5、ss on thepackage is highest at the middle of the pouch where it inflatesto the packages maximum diameter; therefore, Test MethodsF 1140 may not reliably detect the weakest area of the seal.1.3 The burst test internally and increasingly pressurizes apackage until an area of the package seal around th
6、e perimeter“bursts” open in response to pressurization. By placing thepackage within restraining plates during pressurization, thedimensional stability of the package is maintained in a mannerthat results in stresses applied more uniformly along theperimeter of the package, where seals are normally
7、placed.This allows the test to have a higher probability of detecting theweakest area of the seal and provide a measurement of thepressure required to “burst” open the package.1.4 This test only applies to flexible packages with sealsplaced around the perimeter of a flexible package (oftenreferred t
8、o as a pouch). In particular it is intended as applicableto packages with seals that have a peelable seal feature (peeledopen by end user to remove contents of package).1.4.1 Porous barrier materials failure to reach adequatepressure to burst the package seals may be due to insufficientvolume flow.
9、See Appendix X4 for information.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitati
10、ons prior to use. Particular cautionis advised where users of this procedure may be required todesign and fabricate restraining plate fixtures. Reference Ap-pendix X3 for further information regarding calculation ofstress factors and structural design considerations.2. Referenced Documents2.1 ASTM S
11、tandards:2D 1898 Practice for Sampling of Plastics3D 4332 Practice for Conditioning Containers, Packages, orPackaging Components for TestingE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test MethodF88 Test Method for Seal Strength of Flexible BarrierMaterialsF
12、 1140 Test Methods for Internal Pressurization FailureResistance of Unrestrained Packages for Medical Applica-tionsF 1327 Terminology Relating to Barrier Materials for Medi-cal Packaging33. Terminology3.1 DefinitionsFor definitions and terms used in this testmethod, see Terminology F 1327.3.2 Defini
13、tions of Terms Specific to This Standard:3.2.1 flexible package or pouch, nrefers to a package inwhich at least one of the sealed materials is of a flexiblestructure (that is, paper, polyethylene, and so forth).3.2.2 restraining plates, nrefers to plates that are rigid innature and configured to con
14、tact and limit the packagesexpandable surface area as the package is pressurized.4. Summary of Test Method4.1 Packages are tested in an apparatus that internallypressurizes the package until an area of the package ruptures(burst). For most applications the rupture (burst) will occur at1This test met
15、hod is under the jurisdiction of ASTM Committee F02 on FlexibleBarrier Packaging and is the direct responsibility of Subcommittee F02.20 onPhysical Properties.Current edition approved Aug. 1, 2007. Published August 2007. Originallyapproved in 2000. Last previous edition approved in 2005 as F 2054 00
16、 (2005).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.1Copyright ASTM International, 100 Barr Ha
17、rbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.one or more areas of the seal. The pneumatic supply andpressurization equipment need the capability to maintain anincreasing pressure until the seal area fails. (For porous barriermaterial, see Appendix X4.) During pressurizati
18、on, the pack-age shall be enclosed between two rigid and parallel plates(restraining plates) that limit the expansion and dimensionaldistortion of the package but allow the seal perimeter area to beunrestricted. A sensor inside the package detects the internalpressure at the point at which the packa
19、ge ruptures (burst).Dependent on the application, two configurations of restrainingplates are indicated for use with this test method. Generally,these are described as follows:4.1.1 Open Package ConfigurationAn open package con-figuration is used where there is a seal placed around threesides of the
20、 package perimeter and the fourth side is open. Thisconfiguration is generally used in the original package manu-facture. See Fig. 1 for an illustration of the configuration used.4.1.2 Closed Package ConfigurationA closed packageconfiguration is used where there is a seal placed around allfour sides
21、 of the package. This configuration generally is usedin operations where the purpose is to test the seal in itsfinished, fully-sealed state. See Fig. 2 for an illustration of theconfiguration used.5. Significance and Use5.1 This test provides a rapid means of evaluating tenden-cies for package seal
22、failure when the package is exposed to apressure differential. Pressure differentials may occur duringsuch processes as sterilization and transportation. This testmethod provides an indicator of the burst strength of apackage, where the burst will normally occur in one or moreareas of the seal. An i
23、ndicator of the minimum burst strengthmay be of importance to the package manufacturer and enduser in ensuring adequate package integrity. This test methodcannot provide a measure of package seal uniformity. This testmethod also cannot provide an evaluation of overall packageintegrity or the burst s
24、trength of areas of the package thatcontact the surface of the restraining plates used. This testmethod should be combined with other methods of evaluatingoverall package integrity, uniformity of the package seal, oropening functionality, if so required.5.2 This test frequently is used to quickly ev
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF20542007STANDARDTESTMETHODFORBURSTTESTINGOFFLEXIBLEPACKAGESEALSUSINGINTERNALAIRPRESSURIZATIONWITHINRESTRAININGPLATES

链接地址:http://www.mydoc123.com/p-536420.html