《ASTM F2010 F2010M-2010 Standard Test Method for Evaluation of Glove Effects on Wearer Hand Dexterity Using a Modified Pegboard Test《通过改进的有孔游戏板试验评定手套对佩戴者的手部灵活性的影响的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F2010 F2010M-2010 Standard Test Method for Evaluation of Glove Effects on Wearer Hand Dexterity Using a Modified Pegboard Test《通过改进的有孔游戏板试验评定手套对佩戴者的手部灵活性的影响的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2010/F2010M 10Standard Test Method forEvaluation of Glove Effects on Wearer Hand Dexterity Usinga Modified Pegboard Test1This standard is issued under the fixed designation F2010/F2010M; the number immediately following the designation indicates the yearof original adoption or, in the
2、case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is used for evaluating hand dexteritywhile wearing gloves.1.1.1 This te
3、st method covers procedures in which thewearer picks up small objects between the thumb and indexfinger.1.2 This test method is suitable for evaluating gloves andother forms of hand protection that allow the wearer to pick upsmall objects between their thumb and index finger.1.3 This test method doe
4、s not address all effects of glove useon hand function. Other methods should be considered toevaluate the effects of gloves on grip, tactility, and other handfunctions of interest.NOTE 1This test method may not apply to all glove types orapplications.1.4 The values stated in SI units or in other uni
5、ts shall beregarded separately as standard. The values stated in eachsystem must be used independently of the other, withoutcombining values in any way.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of thi
6、s standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F1494 Terminology Relating to Protective Clothing3. Terminology3.1 Definitions:3.1.1 dexterity, na hand function referri
7、ng to the ability ofthe individual to manipulate objects with their hands.3.1.1.1 DiscussionDexterity may be classified as requir-ing fine motor skills in which relatively small objects aremanipulated or those involving gross motor skills in whichrelatively large objects are handled.3.1.2 glove, nan
8、 item of protective clothing designed andconstructed for protecting the hand and wrist.3.1.3 hand function, nthe relative motion and manipula-tive abilities of the hand.3.1.3.1 DiscussionIn this test method, the effect of gloveson a specific hand function, dexterity, is evaluated.3.1.4 protective cl
9、othing, na product which is designedand constructed for the purpose of isolating parts of the bodyfrom a potential hazard.3.1.4.1 DiscussionIn this test method, gloves are evalu-ated to determine the effect on the hand function of the wearer.3.1.5 For definitions of other protective clothing-related
10、terms used in this test method, refer to Terminology F1494.4. Summary of Test Method4.1 The time required for a test subject to place pegs into apegboard is measured without gloves and then later whilewearing gloves. The additional time required to perform thetask while wearing gloves is reported an
11、d is used to indicate theeffects of the gloves on wearer dexterity.5. Significance and Use5.1 The test method is intended to provide a quantitativemeasurement about the effect of gloves on wearer dexterity bycomparing the times required to perform a simple task with andwithout gloves.5.2 This test m
12、ethod does not discriminate all glove effectson wearer hand function or apply to all glove types andapplications. Additional evaluations or tests representative ofthe glove use application should be performed to determine theoverall impact of gloves on wearer hand function.6. Apparatus6.1 Test Appar
13、atus, a pegboard apparatus consisting of 25stainless steel pins and a pegboard. Each stainless steel pinshall have a diameter of 9.5 6 0.26 mm 0.375 6 0.01 in. and1This test method is under the jurisdiction ofASTM Committee F23 on PersonalProtective Clothing and Equipment and is the direct responsib
14、ility of SubcommitteeF23.60 on Human Factors.Current edition approved June 1, 2010. Published July 2010. Originally approvedin 2000. Last previous edition approved in 2005 as F2010 - 00(2005). DOI:10.1520/F2010-10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM C
15、ustomer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.length of 38.0 6 0.25 mm 1.5 6 0
16、.01 in. The pegboard shallbe 200 6 13 mm 8.0 6 0.5 in. The pegboard shall have 25holes with each hole having a diameter of 10.0 6 0.25 mm0.39 6 0.01 in. and a depth of 13.0 6 0.5 mm 0.5 6 0.02in. The holes shall be ina5by5pattern and each hole shallhave a separation of 25 6 2 mm 1.0 6 0.1 in. from a
17、djacentholes.6.2 Stopwatch, to measure the time to place the pegs into thepegboard in seconds.6.3 Test Surface, an area at least 600 by 900 mm 23.5 by33.5 in. with a flat, level, smooth surface having a hardness of50 6 5 Shore A.7. Test Specimen7.1 For each style of glove evaluated, test five pairs
18、(tengloves), preferably of five different sizes. When less than fivedifferent glove sizes are available for the particular glove style,test different pairs of the same size so that a total of at least fivedifferent glove pairs are tested.7.2 Test each glove in new, as distributed, condition. Do nota
19、pply special softening treatments to gloves prior to tests.8. Test Preparation8.1 Evaluate each pair of gloves with a separate test subject.8.2 The hand dimensions of test subjects must be as close aspossible to those specified in manufacturers glove sizingguidelines.8.3 Familiarize test subjects wi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF2010F2010M2010STANDARDTESTMETHODFOREVALUATIONOFGLOVEEFFECTSONWEARERHANDDEXTERITYUSINGAMODIFIEDPEGBOARDTEST

链接地址:http://www.mydoc123.com/p-536282.html