ASTM F1958 F1958M-2012 Standard Test Method for Determining the Ignitability of Non-flame-Resistant Materials for Clothing by Electric Arc Exposure Method Using Mannequins《用人体模型的电弧.pdf
《ASTM F1958 F1958M-2012 Standard Test Method for Determining the Ignitability of Non-flame-Resistant Materials for Clothing by Electric Arc Exposure Method Using Mannequins《用人体模型的电弧.pdf》由会员分享,可在线阅读,更多相关《ASTM F1958 F1958M-2012 Standard Test Method for Determining the Ignitability of Non-flame-Resistant Materials for Clothing by Electric Arc Exposure Method Using Mannequins《用人体模型的电弧.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1958/F1958M 99 (Reapproved 2010) F1958/F1958M 12Standard Test Method forDetermining the Ignitability of Non-flame-Resistant Materialsfor Clothing by Electric Arc Exposure Method UsingMannequins1This standard is issued under the fixed designation F1958/F1958M; the number immediately fol
2、lowing the designation indicates the yearof original adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test metho
3、d is used to identify materials that are ignitable and that can continue to burn when exposed to an electricarc, and determines (a) the incident exposure energy that causes ignition, and (b) the probability of ignition.1.2 The specimens tested in this test method are materials fabricated in the form
4、 of shirts.1.3 This test method shall be used to measure and describe the properties of materials, products, or assemblies in response toconvective and radiant energy generated by an electric arc under controlled laboratory conditions.1.4 The values stated in either SI units or inch-pound units are
5、to be regarded separately as standard. The values stated in eachsystem may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from thetwo systems may result in non-conformance with the standard.1.5 This standard shall not be used to describe o
6、r appraise the fire hazard or fire risk of materials, products, or assemblies underactual fire conditions. However, results of this test may be used as elements of a fire assessment which takes into account all ofthe factors which are pertinent to an assessment of the fire hazard of a particular end
7、 use.1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.1.7 For spec
8、ific precautions, see Section 7.2. Referenced Documents2.1 ASTM Standards:2D123 Terminology Relating to TextilesD4391 Terminology Relating to The Burning Behavior of TextilesF1494 Terminology Relating to Protective ClothingF1506 Performance Specification for Flame Resistant and Arc Rated Textile Mat
9、erials for Wearing Apparel for Use by ElectricalWorkers Exposed to Momentary Electric Arc and Related Thermal HazardsF1959/F1959M Test Method for Determining the Arc Rating of Materials for Clothing2.2 ANSI/IEEE Standards:3Standard Dictionary of Electrical and Electronics Terms33. Terminology3.1 Def
10、initions:3.1.1 See also Terminology D4391.3.1.2 arc duration, ntime duration of the arc, s.1 This test method is under the jurisdiction of ASTM Committee F18 on Electrical Protective Equipment for Workers and is the direct responsibility of SubcommitteeF18.65 on Wearing Apparel.Current edition appro
11、ved Oct. 1, 2010Oct. 1, 2012. Published November 2010November 2012. Originally approved in 1997 as PS 57 97. Last previous edition approvedin 20052010 as F1958/F1958M-99(2005)./F1958M-99(2010). DOI: 10.1520/F1958_F1958M-99R10.10.1520/F1958_F1958M-12.2 For referenced ASTM standards, visit the ASTM we
12、bsite, www.astm.org, or contact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from the Institute of Electrical and Electronic Engineers, Inc., 345 E. 47th St., New York, NY 1
13、0017.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prio
14、r editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.1.3 arc energy, vi dt, nsum of the instan
15、taneous arc voltage values multiplied by the instantaneous arc current valuesmultiplied by the incremental time values during the arc, J.3.1.4 arc gap, ndistance between the arc electrodes, in.cm in.3.1.5 arc voltage, nvoltage across the gap caused by the current flowing through the resistance creat
16、ed by the arc gap, V.3.1.6 asymmetrical arc current, nthe total arc current produced during closure; it includes a direct component and asymmetrical component, A.3.1.7 blowout, nthe extinguishing of the arc caused by a magnetic field.3.1.8 closure, npoint on supply current wave form where arc is ini
17、tiated.3.1.9 delta peak temperature, ndifference between the maximum temperature and the initial temperature of the sensor duringthe test, C.3.1.9 heatflux, nthe thermal intensity indicated by the amount of energy transmitted per unit area and time (cal/cm2s)(W/cm2).3.1.10 i2t, nsum of the instantan
18、eous arc current values squared multiplied by the incremental time values during the arc, A2/s.3.1.11 ignitability, n (ignitable, adj)in electric arc exposure, the property of a material involving ignition accompanied by heatand light, and continued burning resulting in consumption of at least 25 %
19、of the exposed area of the test specimen.3.1.12 ignition, nthe initiation of combustion.3.1.13 incident energy (Ei) , nthe amount of energy (total heat, cal/cm2) received at a surface as a direct result of an electricalarc discharge as measured by temperature rise on copper calorimeters.3.1.14 incid
20、ent energy monitoring sensorssensors mounted on each side of the mannequins.3.1.14.1 DiscussionSensors use the calorimeters described in Test Method F1959/F1959M.3.1.15 peak arc current, nmaximum value of the AC arc current, A.3.1.16 RMS arc current, nroot mean square of the AC arc current, A.3.1.18
21、 time to delta peak temperature, nthe time from beginning of the initiation of the arc to the time the delta peaktemperature is reached, s.3.1.17 X/R ratio, nthe ratio of system inductive reactance to resistance. It is proportional to the L/R ratio of time constant,and is, therefore, indicative of t
22、he rate of decay of any DC offset. A large X/R ratio corresponds to a large time constant and a slowrate of decay.3.2 For definitions of other textile terms used in this test method, refer to Terminologies D123 and F1494.4. Summary of Test Method4.1 This test method exposes a material to heat energy
23、 from an electric arc, and determines (a) the incident exposure energythat causes ignition, and ( b) the probability of ignition.4.1.1 During this procedure, a material is observed for ignitability during and after exposure to an electric arc.4.2 Material performance is determined from the ignitabil
24、ity of the specimen(s).5. Significance and Use5.1 This test method determines the ignitability of materials in single or multiple layers.5.1.1 Material performance shall be determined from the ignitability of the specimen(s) and shall be reported as a probabilityof ignition at various incident energ
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF1958F1958M2012STANDARDTESTMETHODFORDETERMININGTHEIGNITABILITYOFNONFLAMERESISTANTMATERIALSFORCLOTHINGBYELECTRICARCEXPOSUREMETHODUSINGMANNEQUINS

链接地址:http://www.mydoc123.com/p-536139.html