ASTM F1900-1998(2012) Standard Test Method for Water Resistance of Footwear Using a Walking Step Simulator《用行走模拟器进行鞋靴耐水性的标准试验方法》.pdf
《ASTM F1900-1998(2012) Standard Test Method for Water Resistance of Footwear Using a Walking Step Simulator《用行走模拟器进行鞋靴耐水性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1900-1998(2012) Standard Test Method for Water Resistance of Footwear Using a Walking Step Simulator《用行走模拟器进行鞋靴耐水性的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1900 98 (Reapproved 2012)An American National StandardStandard Test Method forWater Resistance of Footwear Using a Walking StepSimulator1This standard is issued under the fixed designation F1900; the number immediately following the designation indicates the year oforiginal adoption or
2、, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a method of measuring thewater resistance of footwear.1
3、.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Do
4、cuments2.1 ASTM Standards:2D2098 Test Method for Dynamic Water Resistance of ShoeUpper Leather by the Dow Corning Leather TesterD2099 Test Method for Dynamic Water Resistance of ShoeUpper Leather by the Maeser Water Penetration Tester2.2 SATRA Test Method:3Physical Test Method PM81 Trough-Water Pene
5、tration Test2.3 FIA Test Methods:4No. 1209, Appendix BWhole Shoe Flex in Water3. Significance and Use3.1 Water resistance is a desirable characteristic for manydifferent types of footwear. This test method provides a guidefor measuring water resistance under dynamic conditions thatclosely duplicate
6、normal human walking. The degree ofcorrelation between this test and footwear performance in thefield or footwear performance in the SATRA Trough-WaterPenetration Test has not been fully determined.4. Apparatus4.1 Mechanism, such as the one shown in Fig. 1, thatapproximates the movements and forces
7、involved in humanwalking motion. The important features of the walking motionproduced by the mechanism are defined as follows:4.1.1 At the beginning of a step (the point where the heel ofthe footwear touches the walking surface) the leg pylonattached to the prosthetic foot shall form an angle of 16
8、6 5(relative to a line perpendicular to the walking surface) asshown in Fig. 2.4.1.2 At the end of a step (the point where the toe of thefootwear departs from the walking surface) the leg pylon shallform an angle 31 6 5 (see Fig. 2).4.1.3 Each step shall begin with no force being exerted onthe footw
9、ear and with the footwear not in contact with thewalking surface. When the footwear contacts the walkingsurface, it shall remain in contact during the entire supportphase of the step and then depart from the walking surface atthe end of the step.4.1.4 During the support phase of each step, a downwar
10、dforce shall be applied to the footwear to simulate the weight ofthe user. The force shall equal one bodyweight of the typicalprospective user, with a tolerance of 610 %, unless a differentforce is specified. Table 1 lists the body masses of 50thpercentile adults and children, and the equivalent one
11、 body-weight downward force levels. If no other downward force isspecified, the values in Table 1 shall be used.NOTE 1The force under the prosthetic foot can be measured with aload cell or force plate.4.2 Mens 26-cm (U.S. Size 9) or Womens 24-cm (U.S. Size7) Right or Left Prosthetic Foot, shall be u
12、sed unless a differentsize is specified. The foot shall closely approximate the shape,texture, and flexibility of a human foot.4.2.1 A minimum of six moisture sensors shall be placed atthe following locations on the prosthetic foot: instep, big toe,inner and outer ball, and inner and outer heel, as
13、illustrated inFig. 3.4.2.2 The moisture sensors shall determine the presence ofwater. A circuit diagram for a sensor that has proven to besuitable for this application is shown in Fig. 4.1This test method is under the jurisdiction of ASTM Committee F08 on SportsEquipment and Facilities and is the di
14、rect responsibility of Subcommittee F08.54 onAthletic Footwear.Current edition approved May 15, 2012. Published August 2012. Originallyapproved in 1998. Last previous edition approved in 2004 as F1900 98 (2004).DOI: 10.1520/F1900-98R12.2For referenced ASTM standards, visit the ASTM website, www.astm
15、.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from SATRA Footwear Technology Centre, Rockingham Road,Kettering, Northamptonshire, NN16 9JH, United Kingdom.4Avai
16、lable from Footwear Industries of America, 1420 K St. NW, Suite 600,Washington, DC.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4.3 Water Tank, made of stainless steel (or other corrosion-resistant material). The tank shall be lar
17、ge enough so that theupper portion of a shoe or boot does not come in contact withthe tank at any time during the test. The tank should have anopening in the front, that is covered by transparent material, topermit observation of the footwear during the test.4.4 Recording Device, that counts the num
18、ber of steps(cycles) that the footwear is subjected to, monitors the moisture(1) Prosthetic foot with moisture sensors(2) Water tank(3) Motor with speed control(4) Mechanism for producing back and forth motion(5) Cam to control location of knee(6) Cam to control location of ankle(7) Slide mechanism(
19、8) Air cylinder to lower the foot at the beginning of each step and raise it again at the completion of eachstepFIG. 1 Footwear TesterF1900 98 (2012)2sensors, and records the number of steps that have beenaccomplished when the sensors become “wet.”5. Reagents5.1 Tap Water, 20 to 25C.6. Test Specimen
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF190019982012STANDARDTESTMETHODFORWATERRESISTANCEOFFOOTWEARUSINGAWALKINGSTEPSIMULATOR 行走 模拟器 进行 耐水性

链接地址:http://www.mydoc123.com/p-535992.html