《ASTM F1869-2009 Standard Test Method for Measuring Moisture Vapor Emission Rate of Concrete Subfloor Using Anhydrous Calcium Chloride.pdf》由会员分享,可在线阅读,更多相关《ASTM F1869-2009 Standard Test Method for Measuring Moisture Vapor Emission Rate of Concrete Subfloor Using Anhydrous Calcium Chloride.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1869 09Standard Test Method forMeasuring Moisture Vapor Emission Rate of ConcreteSubfloor Using Anhydrous Calcium Chloride1This standard is issued under the fixed designation F1869; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the quantitative determinationof the rate of moisture vapor emitted f
3、rom below-grade,on-grade, and above-grade (suspended) bare concrete floors.1.2 This quantity of moisture shall be expressed as the rateof moisture vapor emission, measured in pounds of moistureover a 1000 ft2area during a 24-h period.1.3 This test shall not be used to evaluate moisture emis-sions ov
4、er gypsum concrete.1.4 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are forinformation only.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of thi
5、s standard to establish appro-priate safety and health practices, and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C670 Practice for Preparing Precision and Bias Statementsfor Test Methods for Construction MaterialsF141 Terminology Re
6、lating to Resilient Floor Coverings2.2 Resilient Floor Covering Institute Standard:Recommended Work Practices32.3 Military Standard:Mil Spec B-131H Type 1, Class III42.4 ICRI Guide:Guideline No. 03732: Selecting and Specifying ConcretePreparation for Sealers, Coatings, and Polymer Overlays53. Termin
7、ology3.1 Definitions: See Terminology F141 for definitions of theterms, above-grade (suspended), below-grade, concrete, on-grade, and resilient flooring.3.2 Definitions of Terms Specific to This Standard:3.2.1 moisture vapor emission rate (MVER)amount ofwater vapor in pounds emitted from a 1000 ft2a
8、rea of concreteflooring during a 24-h period (multiply by 56.51 to convert tog/s m2).4. Significance and Use4.1 Use this test method to obtain a quantitative valueindicating the rate of moisture vapor emission from a concretefloor and whether or not that floor is acceptable to receiveresilient floor
9、 covering. The moisture vapor emission rate onlyreflects the condition of the concrete floor at the time of thetest. All concrete subfloors emit some amount of moisture invapor form. Concrete moisture emission is a natural processdriven by environmental conditions. All floor coverings aresusceptible
10、 to failure from excessive moisture vapor emissions.The moisture vapor emitted from a concrete slab is measuredin pounds. This measurement is the equivalent weight of waterevaporating from 1000 ft2of concrete surface in a 24h period.The calcium chloride moisture test has been the industrystandard fo
11、r making this determination and is a practical,well-established and accepted test of dynamic moisture. It willproduce quantified results directly applicable to flooring manu-facturers specifications. The results obtained reflect only thecondition of the concrete floor at that time.5. Apparatus5.1 Te
12、st Unit Contents:1This test method is under the jurisdiction ofASTM Committee F06 on ResilientFloor Coverings and is the direct responsibility of Subcommittee F06.40 onPractices.Current edition approved Dec. 1, 2009. Published January 2010. Originallyapproved in 1998. Last previous edition approved
13、in 2004 as F186904. DOI:10.1520/F1869-09.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Resi
14、lient Floor Covering Institute, 966 Hungerford Drive, Suite12-B, Rockville, MD 20850.4Available from Standardization Documents Order Desk, Bldg. 4 Section D, 700Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.5Available from International Concrete Repair Institute, International ConcreteRepai
15、r Institute 3 166 S. River Road, Suite 132, Des Plaines, IL 60018;,www.icri.org1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.1.1 Cylindrical Plastic Dish Containing Anhydrous Cal-cium Chloride, heat sealed in a heat sealable bag
16、meeting MilSpec B-131H Type 1, Class III, to protect from moistureintrusion.5.1.1.1 Anhydrous calcium chloride shall be in the form ofprilled beads and shall have a minimum purity of 94 %. Netweight of the anydrous calcium chloride shall be 16 6 1g.5.1.1.2 Dish shall be made of a material that does
17、not absorbmoisture. Dimensions of the dish shall be 69 6 1 mm outsidediameter, 16 6 1 mm height, wall thickness less than 1 mm.Dish shall be supplied with a tight-fitting cover. The cover shallbe secured to the dish with pressure-sensitive-adhesive backedvinyl tape.5.1.2 Pressure Sensitive Label, to
18、 be used to identify thecontainer of calcium chloride and to record the date, time, andcontainer weight when the test is started and completed.5.1.3 Transparent Cover, with 0.5 in. (12 mm) flangesaround the perimeter, approximately 0.5 ft2(460 6 46 cm2), asmeasured between the inside of the flanges,
19、 is required to sealthe test area of the floor. The plastic cover shall have a depthgreater than the height of the container of anhydrous calciumchloride. The height of the container shall be 112 in. 6 0.125(38 6 3.2 mm).5.1.4 Strip of Sealant, to secure the plastic cover to the floorin an airtight
20、fashion.5.1.5 Brightly Colored Warning Label, to be placed on theplastic cover as a protective warning while the test is beingconducted.5.1.6 Mailing Bag, for the return of the sample to the partyresponsible for calculating the test results.5.2 Gram Scale, capable of measuring 0.1 g. This scale will
21、be used to weigh the calcium chloride container at the start andend of the test. On-site measurement is preferred to mailing thecontainer back to the supplier for results.5.3 Thermometer, capable of measuring room temperature.5.4 Hygrometer, capable of measuring the relative humidityof the test site
22、.6. Conditioning6.1 The test site should be at the same temperature andhumidity expected during normal use. If this is not possible,then the test conditions should be 75 6 10F (23.9 6 5.5C)and 50 6 10 % relative humidity. Maintain these conditions 48h prior to, and during testing.6.2 Prior to placem
23、ent of the anhydrous calcium chloridetests, the actual test area shall be clean and free of all foreignsubstances. All residual adhesives, curing compounds, sealers,paints, floor coverings, etc. shall be removed. Removal shall beaccomplished using approved OSHA work practices. Forremoval of existing
24、 resilient floorings or residual adhesive,strictly observe the Warning that follows and Notes 1 and 2.(WarningDo not sand, dry sweep, dry scrape, drill, saw,beadblast, or mechanically chip or pulverize existing resilientflooring, backing, lining felt, or asphaltic cut-back adhesives.These products m
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF18692009STANDARDTESTMETHODFORMEASURINGMOISTUREVAPOREMISSIONRATEOFCONCRETESUBFLOORUSINGANHYDROUSCALCIUMCHLORIDEPDF

链接地址:http://www.mydoc123.com/p-535901.html