《ASTM F1815-2006 Standard Test Methods for Saturated Hydraulic Conductivity Water Retention Porosity and Bulk Density of Putting Green and Sports Turf Root Zones《小型高尔夫球场绿呢和运动草皮根层的饱和.pdf》由会员分享,可在线阅读,更多相关《ASTM F1815-2006 Standard Test Methods for Saturated Hydraulic Conductivity Water Retention Porosity and Bulk Density of Putting Green and Sports Turf Root Zones《小型高尔夫球场绿呢和运动草皮根层的饱和.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1815 06An American National StandardStandard Test Methods forSaturated Hydraulic Conductivity, Water Retention, Porosity,and Bulk Density of Putting Green and Sports Turf RootZones1This standard is issued under the fixed designation F 1815; the number immediately following the designa
2、tion indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the mea
3、surements of saturatedhydraulic conductivity, water retention, porosity (includingdistribution of capillary and air-filled porosity at a known soilsuction), and bulk density on sand-based root zone mixes to beused for construction and topdressing of golf course puttinggreens including United States
4、Golf Association (USGA)recommended greens, golf course tees, sand-based sportsfields, or other highly trafficked turfgrass areas. These testmethods are designed for sand-based mixes and are notintended for use with fine or medium textured soils, forexample, sandy loams and loams.1.2 The values state
5、d in SI units are to be regarded as thestandard. The inch-pound units given in parentheses are forinformation only.1.3 This standard does not purport to address all of thesafety concerns associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and
6、health practices and determine the applicability of regulatorylimitations prior to its use.2. Referenced Documents2.1 ASTM Standards:2D 854 Test Methods for Specific Gravity of Soil Solids byWater PycnometerD 2216 Test Methods for Laboratory Determination of Wa-ter (Moisture) Content of Soil and Roc
7、k by MassD 2974 Test Methods for Moisture, Ash, and Organic Mat-ter of Peat and Other Organic SoilsD 4643 Test Method for Determination of Water (Moisture)Content of Soil by the Microwave Oven MethodD 4959 Test Method for Determination of Water (Moisture)Content of Soil By Direct Heating MethodD 555
8、0 Test Method for Specific Gravity of Soil Solids byGas PycnometerE 11 Specification for Wire Cloth and Sieves for TestingPurposesF 1647 Test Methods for Organic Matter Content of PuttingGreen and Sports Turf Root Zone Mixes3. Summary of Test Method3.1 Test Method ASaturated hydraulic conductivity i
9、sdetermined on compacted, saturated mix or sand soil cores.Water flow through the core is maintained at a constanthydraulic head until a steady flow rate is achieved, at whichtime aliquots of the outflow are collected.3.2 Test Method BWater retention is obtained at a soilsuction as defined by the de
10、sign architect or engineer in thespecifications. In lieu of a specification, or if testing for USGAgreens, the water retention shall be determined at a soil suctionof 30 cm. The water shall be extracted from a prepared core bymeans of a tension table or other water extraction apparatus.When equilibr
11、ium is achieved, the weight is recorded. The coreis oven dried at 105C until a constant weight is obtained.Water retention is calculated on an oven dried basis. Bulkdensity is calculated from the mix or sand dry weight andvolume.3.3 Test Method CTotal porosity is calculated from thebulk density and
12、particle density.3.4 Test Method DCapillary porosity is calculated fromthe bulk density and water retention information. Air-filled oraeration porosity is calculated from the difference of total andcapillary porosity.4. Apparatus4.1 Cylinders, made of metal, PVC, or similar rigid mate-rials shall ha
13、ve an inside diameter of 51 or 76+2mm(2or3+ 0.08 in.), and a height of 76+2mm(3+0.08 in.).4.2 Compactor, shall be such as to exert a total potentialenergy of 3.03 J/cm2(14.3 ft-lb/in.2) across the cross-sectionalarea of the core. Fig. 1 shows an example of such a devicewhere a weighted hammer is dro
14、pped 15 times from a height of305+2mm(12+0.08 in.).A51 mm (2 in.) diameter core will1These test methods are under the jurisdiction of ASTM Committee F08 onSports Equipment and Facilities and are the direct responsibility of SubcommitteeF08.64 on Natural Playing Surfaces.Current edition approved Nov.
15、 15, 2006. Published December 2006. Originallyapproved in 1997. Last previous edition approved in 1997 as F 1815 97 which waswithdrawn in August 2006 and reinstated in December 2006.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.o
16、rg. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.require 15 drops of a 1.36 kg (3 lb) hammer from a height of305
17、mm (12 in.). A 76 mm core will require 15 drops of a 3.02kg (6.7 lb) hammer from a height of 305 mm (12 in). The dropsshall be completed within 1 min. The compactor shall rest ona rigid foundation such as a cube of concrete with a mass of notless than 40 kg (90 lb). Secure the base of the compactor
18、to thefoundation. The diameter of the compaction foot should besufficient to prevent binding with the inside wall of thecylinder, but no more than 2 mm smaller in diameter than theinside diameter of the cylinder. The clearance between bush-ings and the guide rod should be sufficient to prevent bindi
19、ng,but should be no greater than 2 mm.4.3 Permeameter, capable of maintaining a constant head ofwater for several hours.4.4 Tension or Porous Plate Apparatus, capable of extract-ing water out of the cores at a soil suction of up to 4 kPa (40cm suction). Fig. 2 shows an example of a tension table.4.5
20、 Oven, capable of maintaining a constant temperature of105 6 5C.4.6 BalanceA balance sensitive to 0.1 g.4.7 Thermometer, accurate to 0.5C.4.8 Sieves, No. 5 (4 mm).5. Preparation of Samples5.1 Premixed Samples:5.1.1 The cylinders should be prepared by attaching adouble layer of cheesecloth or other s
21、uitable cloth material,including brass, stainless steel, or fiberglass, onto the bottom ofeach cylinder. The cheesecloth or other material should betrimmed to a consistent size prior to or after placement on thecylinder. Weigh and record the weight of each cylinder.5.1.2 Screen the root zone mixture
22、 through a No. 5 (4 mm)sieve to remove peat clods and other debris. Peat clods shouldbe broken up and returned to the sample.5.1.3 In mixes containing peat or other organic amend-ments, determine percent organic matter using one of themethods in Test Methods F 1647 to quantify organic mattercontent
23、on a weight basis. This value and the method usedshould be reported so that field checks of mixes can be madeto assure that the mix corresponds to that developed in thelaboratory5.1.4 The gravimetric water content of the sample shall bedetermined by a referenced (Test Methods D 2216, D 4643,D 4959)
24、or other appropriate method. The water content of thesample shall be adjusted to 8 + 0.5 % by adding water to thesample by misting if the antecedent water content is below8 %, or by air drying the sample if the antecedent water contentis above 8 %. Water content is expressed on a dry weight basis(wt
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF18152006STANDARDTESTMETHODSFORSATURATEDHYDRAULICCONDUCTIVITYWATERRETENTIONPOROSITYANDBULKDENSITYOFPUTTINGGREENANDSPORTSTURFROOTZONES

链接地址:http://www.mydoc123.com/p-535742.html