1、Designation: F1701 12 (Reapproved 2018)Standard Specification forUnused Rope with Special Electrical Properties1This standard is issued under the fixed designation F1701; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the requirements, sizes,construction, tests, and procedures for unused ropes for use byelect
3、rical utilities and related industries on energized linesoperating at voltages higher than 1 kV.1.2 This specification covers the minimum electrical,mechanical, and physical properties guaranteed by the manu-facturer and the detailed procedures by which such propertiesare to be determined. The purch
4、aser has the option to performor have performed any of these tests in order to verify theguarantee. Claims for failure to meet the specification aresubject to verification by the manufacturer.1.3 The rope to which this specification applies is designedto be used in a clean and dry condition, on or n
5、ear energizedlines.1.4 A margin of safety shall be allowed between themaximum voltage and working distances on which it is usedand the test voltage and lengths at which it is tested.1.5 It is common practice for the user of this type ofequipment to prepare complete instructions and regulations togov
6、ern in detail the correct and safe use of such equipment.1.6 The use and maintenance of this equipment is beyondthe scope of this specification.1.7 The values stated in SI units are to be regarded as thestandard.1.8 The following safety hazards caveat pertains only to thetest method portion, Section
7、 11, of this specification: Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety, health, andenvironmental practices and determine the applicability ofregulatory limit
8、ations prior to use. The test levels used in thisstandard are for testing under laboratory conditions and are notto be regarded as safe use levels.1.9 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision o
9、n Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C1500 Test Method for Nondestructive Assay of Plutoniumby Passive Neutron Multiplicity
10、CountingD1125 Test Methods for Electrical Conductivity and Resis-tivity of WaterD4268 Test Methods for Testing Fiber Ropes (Withdrawn2002)3E4 Practices for Force Verification of Testing MachinesF711 Specification for Fiberglass-Reinforced Plastic (FRP)Rod and Tube Used in Live Line Tools2.2 IEEE Sta
11、ndards:4IEEE Std 4 Standard Techniques for High Voltage Testing2.3 Other Standard:5Cordage Institute CI-1301 Polypropylene Fiber Rope3-Strand and 8-Strand Constructions (April 1999)3. Terminology3.1 GeneralThe terms used in this specification are com-mon to and well known by the industries that will
12、 be usingthem.4. Ordering Information4.1 Orders for rope under this specification should includethe following information:4.2 Manufacturers designation of the rope.4.3 Length of Coil or Reel:1This specification is under the jurisdiction of ASTM Committee F18 onElectrical Protective Equipment for Wor
13、kers and is the direct responsibility ofSubcommittee F18.35 on Tools (2) dry electrical (Refer to 11.3); (3) wet electrical (Refer to11.4); (4) mechanical/physical (Refer to 11.5).11.2 CautionIt is recommended that the test apparatus bedesigned to afford the operator full protection in performanceof
14、 his duties. Reliable means of deenergizing and groundingthe high-voltage circuit shall be provided.11.3 Electrical Test Procedure Dry TestThis is a dryspecimen test to be used on new rope prior to wet test.11.3.1 Specimen for TestWhen selected in accordancewith Section 8, the test specimen shall be
15、 at least 1.8 m (6 ft)long so that when the rope is held in a vertical position, therewill be 1.0 m (3 ft) of rope free from knots, eyes, or splices (seeFig. 1).11.3.2 Handling of SpecimenWhen the rope is handled, itshall always be outside the test footage (see Fig. 1).11.3.3 Electrodes:11.3.3.1 The
16、 electrodes shall be designed to shield out themajority of stray capacitive currents.11.3.3.2 The electrodes and configuration shall be the sameas those in Fig. 2, or the alternate setup in Fig. 3, which aresimilar to those specified in Specification F711 for testing FRPFIG. 1 Test Footage for Elect
17、rical TestF1701 12 (2018)2rod and tube (see Fig. 4). Electrical contact is made throughclamps that fit snugly around the rope. The electrodes shall bemounted in a suitable frame like Fig. 2 to allow the suspensionof the 305 mm (12 in.) 6 13 mm (12 in.) test section betweenthe electrodes. A 4.5 kg (1
18、0 lb) weight shall be attached to therope to maintain good electrical contact. (See Fig. 5 for clampand plate details of Fig. 2).11.3.4 Dry Test Leakage ReadingsThe 60 Hz voltage shallbe raised from 0 to 100 kV rms in not less than 5 nor more than15 s. The voltage shall be held at 100 kV rms for 5 m
19、in. If atthe end of 5 min the current is stable or dropping and has notexceeded 100 A at any time during the test, or flashed over,the specimen has passed the test. If at the end of 5 min thecurrent is rising and not stable but does not exceed 100 A, orflashover, the test shall continue for an addit
20、ional 25 min. If atthe end of that time the rope has not flashed over and thecurrent has stabilized at less than 100 A, the specimen haspassed.11.4 Electrical Test Procedure-Wet Test:11.4.1 Specimen for TestWhen selected in accordancewith Section 8, the test specimen shall be at least 1.8 m (6 ft)lo
21、ng so that when the rope is held in a vertical position, therewill be 1.0 m (3 ft) of rope free from knots, eyes, or splices (seeFig. 1).11.4.2 Handling of SpecimenWhen the rope is handled, itshall always be outside the test footage (see Fig. 1).11.4.3 Electrodes:11.4.3.1 The electrodes shall be des
22、igned to shield out themajority of stray capacitive currents.11.4.3.2 The electrodes and configuration shall be the sameas those in Fig. 2, or the alternate setup in Fig. 3, which aresimilar to those specified in Specification F711 for testing FRProd and tube (see Fig. 4). Electrical contact is made
23、 throughclamps that fit snugly around the rope. The electrodes shall bemounted in a suitable frame like Fig. 2 to allow the suspensionof the 305 mm (12 in.) 6 13 mm (12 in.) test section betweenthe electrodes. A 4.5 kg (10 lb) weight shall be attached to therope to maintain good electrical contact.
24、(See Fig. 5 for clampand plate details of Fig. 2).11.4.4 Conditioning of Specimen:11.4.4.1 The weight of the preconditioned sample should betaken and recorded to the nearest milligram. Loss of hydro-phobic coating could reduce weight saturation and should beconsidered a failure.11.4.4.2 The entire r
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF170120122018STANDARDSPECIFICATIONFORUNUSEDROPEWITHSPECIALELECTRICALPROPERTIESPDF

链接地址:http://www.mydoc123.com/p-535447.html