ASTM F1642-2004 Standard Test Method for Glazing and Glazing Systems Subject to Airblast Loadings《强气流荷载下门窗玻璃和玻璃装配系统的标准试验方法》.pdf
《ASTM F1642-2004 Standard Test Method for Glazing and Glazing Systems Subject to Airblast Loadings《强气流荷载下门窗玻璃和玻璃装配系统的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1642-2004 Standard Test Method for Glazing and Glazing Systems Subject to Airblast Loadings《强气流荷载下门窗玻璃和玻璃装配系统的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1642 04Standard Test Method forGlazing and Glazing Systems Subject to Airblast Loadings1This standard is issued under the fixed designation F 1642; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last rev
2、ision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.INTRODUCTIONHistorical records show that fragments from glazing that has failed as the result of intentional oraccidental explosions pres
3、ent a serious threat of personal injury. Glazing failure also allows blastpressure to enter the interior of buildings thus resulting in additional threat of personal injury andfacility damage. These risks increase in direct proportion to the amount of glazing used on the buildingfacade. This test me
4、thod addresses only glazing and glazing systems. It assumes that the designer hasverified that other structural elements have been adequately designed to resist the anticipated airblastpressures.1. Scope1.1 This test method sets forth procedures for the evaluationof hazards of glazing or glazing sys
5、tems against airblastloadings. The specifying authority shall provide the airblastloading parameters.1.2 This test method allows for glazing to be tested andrated with or without framing systems.1.3 This test method is designed to test and rate all glazing,glazing systems, and glazing retrofit syste
6、ms including, but notlimited to, those fabricated from glass, plastic, glass-cladplastics, laminated glass, glass/plastic glazing materials, andfilm-backed glass.1.4 The values stated in SI units are to be regarded as thestandard. Values given in parentheses are for information only.For conversion o
7、f quantities in various systems of measure-ments to SI units, see SI 10.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine t
8、he applica-bility of regulatory limitations prior to use. See Section 9 forspecific hazards statements.2. Referenced Documents2.1 ASTM Standards:2E 997 Test Method for Structural Performance of Glass inExterior Windows, Curtain Walls, and Doors Under theInfluence of Uniform Static Loads by Destructi
9、ve MethodsSI 10 American National Standard for Use of the Interna-tional System of Units (SI): The Modern Metric System23. Terminology3.1 Definitions:3.1.1 ambient temperature24 6 11C (75 6 20F).3.1.2 blast mata steel or concrete pad upon which highexplosive may be detonated to reduce the incidence
10、of ejecta.3.1.3 effective positive phase duration (T)the duration ofan idealized triangular positive phase reflected airblast pressurehistory, having an instantaneous rise to the measured P, with alinear decay to ambient, such that the impulse of the idealizedpressure history equals i of the measure
11、d positive phasereflected airblast history.3.1.3.1 DiscussionThe idealized triangular airblast waveis considered to provide a reliable standard measure of thepositive phase airblast intensity.3.1.4 glazingtransparent materials used for windows,doors, or other panels.3.1.5 glazing systemthe assembly
12、comprised of the glaz-ing, its framing system, and anchorage devices.3.1.6 peak positive pressure (P)the maximum measuredpositive phase airblast pressure, kPa.3.1.7 positive phase impulse (i)the integral of the mea-sured positive phase reflected airblast pressure history, kPa-ms(psi-ms) (more correc
13、tly called the specific positive phaseimpulse).3.1.8 reflected airblast pressurethe pressure increase thata surface, oriented other than parallel to the line from thedetonation point to the surface, experiences due to the detona-tion of a high explosive charge.1This test method is under the jurisdic
14、tion of ASTM Committee F12 on SecuritySystems and Equipment and is the direct responsibility of Subcommittee F12.10 onSystems Products and Services.Current edition approved Feb. 1, 2004. Published March 2004. Originallyapproved in 1995. Last previous edition approved in 2003 as F 1642 03.2For refere
15、nced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West
16、Conshohocken, PA 19428-2959, United States.3.1.8.1 DiscussionThe reflected airblast pressure history,whether reflected or otherwise, as measured at a point on thesurface, consists of two separate phases. The positive phase ischaracterized by a nearly instantaneous rise to a maximumpressure followed
17、by an exponential decay to ambient pressure.In the negative phase, which follows immediately the positivephase, the pressure decreases below ambient for a period oftime before returning to ambient.3.1.9 simply supported glazingglazing supported in ac-cordance with Test Method E 997 with the edges of
18、 the glassextending a minimum of 3-mm (0.125-in.) beyond the neo-prene supports.3.1.10 test directorthe individual identified by the inde-pendent testing laboratory as being responsible to complete thespecified tests as required and to document the results, inaccordance with this test method.4. Summ
19、ary of Test Method4.1 This test method prescribes the required apparatus,procedures, specimens, and other requirements necessary todetermine the hazard rating of a glazing or glazing systemsubjected to an airblast loading.5. Significance and Use5.1 This test method provides a structured procedure to
20、establish the hazard rating of glazing and glazing systemssubjected to an airblast loading. Knowing the hazard ratingprovides the ability to assess the risk of personal injury andfacility damage.5.2 The hazard rating for a glazing or glazing material doesnot imply that a single specimen will resist
21、the specific airblastfor which it is rated with a probability of 1.0. The probabilitythat a single glazing or glazing construction specimen willresist the specific airblast for which it is rated increasesproportionally with the number of test specimens that success-fully resist the given level of ai
22、rblast to the hazard level forwhich it is rated.6. Number of Specimens6.1 Number of SpecimensA minimum of three test speci-mens representative of a glazing or glazing system, or a glazingretrofit system, shall be tested at a given level of airblast,defined in terms of P and i.7. Hazard Rating7.1 The
23、 hazard rating of the glazing or glazing system shallbe according to the rating criteria definitions provided belowand further demonstrated in Fig. 1. The hazard rating thatglazing or glazing systems receive is based upon the severity offragments generated during an airblast test. The fragmentseveri
24、ty is determined based upon the number, size andlocation of fragments observed during post-test data gathering.Fragments to be considered in rating the glazing or glazingsystem include those generated by the glazing, and any otherparts of the glazing system not considered to be part of the testfacil
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF16422004STANDARDTESTMETHODFORGLAZINGANDGLAZINGSYSTEMSSUBJECTTOAIRBLASTLOADINGS 气流 荷载 门窗 玻璃 装配 系统

链接地址:http://www.mydoc123.com/p-535305.html