《ASTM F1504-2010 Standard Specification for Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer and Conduit Rehabilitation《现有污水管和下水管修复用波纹聚乙烯(氯乙烯)(聚氯乙烯)管的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1504-2010 Standard Specification for Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer and Conduit Rehabilitation《现有污水管和下水管修复用波纹聚乙烯(氯乙烯)(聚氯乙烯)管的标准规范》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1504 10An American National StandardStandard Specification forFolded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewerand Conduit Rehabilitation1This standard is issued under the fixed designation F1504; the number immediately following the designation indicates the year oforiginal ad
2、option or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers requirements and test methodsfor materials,
3、 dimensions, workmanship, flattening resistance,impact resistance, pipe stiffness, extrusion quality, and a formof marking for folded (vinyl chloride) (PVC) pipe for existingsewer and conduit rehabilitation.1.2 Pipe produced to this specification is for use in non-pressure sewer and conduit rehabili
4、tation where the foldedPVC pipe is inserted into and then expanded to conform to thewall of the original conduit forming a new structural pipe-within-a-pipe.NOTE 1For installation procedures refer to Practice F1947.1.3 This specification includes pipe made only from mate-rials specified in Section 6
5、. This specification does not includepipe manufactured from reprocessed, recycled, or reclaimedPVC.1.4 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not consid
6、ered standard.1.5 The following precautionary statement pertains to thetest method portion only, Section 11, of this specification: Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish a
7、ppropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD790 Test Methods for Flexural Properties of Unreinforcedand Reinforced Plastics and Electrical
8、Insulating MaterialsD1600 Terminology for Abbreviated Terms Relating toPlasticsD1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)Compounds and Chlorinated Poly(Vinyl Chloride)(CPVC) CompoundsF1947 Practice for Installation of Folded Poly (Vinyl Chlo-ride) (PVC) Pipe into Existing Sewers and Co
9、nduitsD2122 Test Method for Determining Dimensions of Ther-moplastic Pipe and FittingsD2152 Test Method for Adequacy of Fusion of ExtrudedPoly(Vinyl Chloride) (PVC) Pipe and Molded Fittings byAcetone ImmersionD2412 Test Method for Determination of External LoadingCharacteristics of Plastic Pipe by P
10、arallel-Plate LoadingD2444 Test Method for Determination of the Impact Resis-tance of Thermoplastic Pipe and Fittings by Means of aTup (Falling Weight)F412 Terminology Relating to Plastic Piping SystemsF1057 Practice for Estimating the Quality of Extruded Poly(Vinyl Chloride) (PVC) Pipe by the Heat
11、Reversion Tech-nique2.2 Federal Standard:Fed. Std. No. 123 Marking for Shipment (Civil Agencies)32.3 Military Standard:MIL-STD-129 Marking for Shipment and Storage33. Terminology3.1 GeneralAbbreviations used in this specification are inaccordance with Terminology D1600 and definitions are inaccordan
12、ce with Terminology F412 unless otherwise indicated.3.2 Definitions of Terms Specific to This Standard:3.2.1 folded pipepipe that has been manufactured in afolded shape or that is subsequently folded for use in existingsewer and conduit rehabilitation. See Fig. 1.3.2.2 rounded pipeA rounded pipe is
13、a sample for testpurposes formed when the folded pipe has been inserted into acircular casing pipe and expanded with heat and pressure to fittightly to the casing pipe taking a circular cross section, inaccordance with Section 10. See Fig. 1.1This specification is under the jurisdiction of ASTM Comm
14、ittee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.67 onTrenchless Plastic Pipeline Technology.Current edition approved Nov. 15, 2010. Published January 2011. Originallyapproved in 1994. Last previous edition approved in 2002 as F1504 02. DOI:10.1520/F1504-10.2Fo
15、r referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Standardization Documents Order Desk, DODSSP, Bl
16、dg. 4,Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http:/dodssp.daps.dla.mil.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4. Significance and Use4.1 Th
17、e requirements of this specification are intended toprovide folded pipe suitable for the rehabilitation of existingpipelines and conduits conveying sewage, process flow, andstorm water, under nonpressure conditions, through the heat-ing, insertion, and expansion of the folded pipe.NOTE 2Industrial w
18、aste disposal lines should be installed only withthe specific approval of the cognizant code authority since chemicals notcommonly found in drains and sewers and temperatures in excess of140F (60C) may be encountered.5. Application of Materials5.1 The nominal folded PVC pipe sizes specified in Secti
19、on8 are applicable for a range of original pipe inside diameters.Table 1 lists the recommended ranges for each nominal size.6. Materials and Manufacture6.1 Basic MaterialsThe pipe shall be made from virginPVC compound meeting all the requirements for cell classifi-cations 12334, or 13223 as defined
20、in Specification D1784.6.2 Rework MaterialClean rework material, generatedfrom the manufacturers own PVC sewer pipe production maybe used by the same manufacturer provided that the reworkmaterial meets the requirements of 6.1 and that the pipeproduced meets all the requirements of this specification
21、.7. Other Requirements7.1 Pipe FlatteningThere shall be no evidence of split-ting, cracking, or breaking when the rounded pipe is tested inaccordance with 11.3.7.2 Pipe Impact StrengthThe impact strength of therounded pipe shall not be less than the values given in Table 2when tested in accordance w
22、ith 11.4.NOTE 3This test is intended only for use as a quality-control test, notas a simulated service test.7.3 Pipe StiffnessPipe stiffness values for the roundedpipe shall comply with Table 3 when tested in accordance with11.6.7.4 Extrusion QualityThe extrusion quality of the pipeshall be evaluate
23、d by both of the following test methods.7.4.1 Acetone ImmersionThe pipe shall not flake or dis-integrate when tested in accordance with 11.6.1.7.4.2 Heat ReversionThe extrusion quality shall be esti-mated by heat reversion method in accordance with 11.6.2.7.5 Flexural PropertiesFlexural modulus of e
24、lasticityvalues for the rounded pipe shall comply with Table 4 whentested in accordance with 11.7.8. Dimensions, Mass, and Permissible Variations8.1 Rounded Pipe DiameterThe average outside diameterof the rounded pipe shall meet the requirements given in Table5 with a tolerance of 61.0 % when measur
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF15042010STANDARDSPECIFICATIONFORFOLDEDPOLYVINYLCHLORIDEPVCPIPEFOREXISTINGSEWERANDCONDUITREHABILITATION

链接地址:http://www.mydoc123.com/p-535021.html