ASTM F1504-2002 Standard Specification for Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer and Conduit Rehabilitation《现有污水管和下水管修复用折叠式聚氯乙烯管的标准规范》.pdf
《ASTM F1504-2002 Standard Specification for Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer and Conduit Rehabilitation《现有污水管和下水管修复用折叠式聚氯乙烯管的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1504-2002 Standard Specification for Folded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewer and Conduit Rehabilitation《现有污水管和下水管修复用折叠式聚氯乙烯管的标准规范》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1504 02An American National StandardStandard Specification forFolded Poly(Vinyl Chloride) (PVC) Pipe for Existing Sewerand Conduit Rehabilitation1This standard is issued under the fixed designation F 1504; the number immediately following the designation indicates the year oforiginal
2、adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers requirements and test methodsfor material
3、s, dimensions, workmanship, flattening resistance,impact resistance, pipe stiffness, extrusion quality, and a formof marking for folded (vinyl chloride) (PVC) pipe for existingsewer and conduit rehabilitation.1.2 Pipe produced to this specification is for use in non-pressure sewer and conduit rehabi
4、litation where the foldedPVC pipe is inserted into and then expanded to conform to thewall of the original conduit forming a new structural pipe-within-a-pipe.NOTE 1An ASTM specification for the installation of folded PVCpipe is under preparation and will be referenced in this specification whenpubl
5、ished.1.3 This specification includes pipe made only from mate-rials specified in Section 6. This specification does not includepipe manufactured from reprocessed, recycled, or reclaimedPVC.1.4 The values stated in inch-pound units are to be regardedas the standard. The SI units given in parentheses
6、 are providedfor information only.1.5 The following precautionary statement pertains to thetest method portion only, Section 11, of this specification: Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this sta
7、ndard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:D 618 Practice for Conditioning Plastics for Testing2D 790 Test Methods for Flexural Properties of Unreinforcedand Reinforced Pl
8、astics and Electrical Insulating Materi-als2D 1600 Terminology for Abbreviated Terms Relating toPlastics2D 1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)Compounds and Chlorinated Poly(Vinyl Chloride)(CPVC) Compounds2D 2122 Test Method of Determining Dimensions of Ther-moplastic Pipe and Fit
9、tings3D 2152 Test Method for Adequacy of Fusion of ExtrudedPoly(Vinyl Chloride) (PVC) Pipe and Molded Fittings byAcetone Immersion3D 2412 Test Method of Determination of External LoadingCharacteristics of Plastic Pipe by Parallel-Plate Loading3D 2444 Test Method for Determination of Impact Resis-tan
10、ce of Thermoplastic Pipe and Fittings by Means of aTup (Falling Weight)3F 412 Terminology Relating to Plastic Piping Systems3F 1057 Practice for Estimating the Quality of ExtrudedPoly(Vinyl Chloride) (PVC) Pipe by the Heat ReversionTechnique32.2 Federal Standard:Fed. Std. No. 123 Marking for Shipmen
11、t (Civil Agencies)42.3 Military Standard:MIL-STD-129 Marking for Shipment and Storage43. Terminology3.1 GeneralAbbreviations used in this specification are inaccordance with Terminology D 1600 and definitions are inaccordance with Terminology F 412 unless otherwise indi-cated.3.2 Definitions of Term
12、s Specific to This Standard:3.2.1 folded pipepipe that has been manufactured in afolded shape or that is subsequently folded for use in existingsewer and conduit rehabilitation. See Fig. 1.3.2.2 rounded pipeA rounded pipe is a sample for testpurposes formed when the folded pipe has been inserted int
13、o acircular casing pipe and expanded with heat and pressure to fittightly to the casing pipe taking a circular cross section, inaccordance with Section 10. See Fig. 1.1This specification is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subc
14、ommittee F17.67 onTrenchless Plastic Pipeline Technology.Current edition approved Sept. 10, 2002. Published December 2002 Originallypublished as F 1504 94. Last previous edition F 1504 97e1.2Annual Book of ASTM Standards, Vol 08.01.3Annual Book of ASTM Standards, Vol 08.04.4Available from Standardiz
15、ation Documents Order Desk, Bldg. 4 Section D, 700Robbins Ave., Philadelphia, PA 19111-5094, Attn: NPODS.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4. Significance and Use4.1 The requirements of this specification are intended t
16、oprovide folded pipe suitable for the rehabilitation of existingpipelines and conduits conveying sewage, process flow, andstorm water, under gravity flow conditions, through the heat-ing, insertion, and expansion of the folded pipe.NOTE 2Industrial waste disposal lines should be installed only witht
17、he specific approval of the cognizant code authority since chemicals notcommonly found in drains and sewers and temperatures in excess of140F (60C) may be encountered.5. Application of Materials5.1 The nominal folded PVC pipe sizes specified in Section8 are applicable for a range of original pipe in
18、side diameters.Table 1 lists the recommended ranges for each nominal size.6. Materials and Manufacture6.1 Basic MaterialsThe pipe shall be made from virginPVC compound meeting all the requirements for cell classifi-cations 12334, or 13223 as defined in Specification D 1784.6.2 Rework MaterialClean r
19、ework material, generatedfrom the manufacturers own PVC sewer pipe production maybe used by the same manufacturer provided that the reworkmaterial meets the requirements of 6.1 and that the pipeproduced meets all the requirements of this specification.7. Other Requirements7.1 Pipe FlatteningThere sh
20、all be no evidence of split-ting, cracking, or breaking when the rounded pipe is tested inaccordance with 11.3.7.2 Pipe Impact StrengthThe impact strength of therounded pipe shall not be less than the values given in Table 2when tested in accordance with 11.4.NOTE 3This test is intended only for use
21、 as a quality-control test, notas a simulated service test.7.3 Pipe StiffnessPipe stiffness values for the roundedpipe shall comply with Table 3 when tested in accordance with11.6.7.4 Extrusion QualityThe extrusion quality of the pipeshall be evaluated by both of the following test methods.7.4.1 Ace
22、tone ImmersionThe pipe shall not flake or dis-integrate when tested in accordance with 11.6.1.7.4.2 Heat ReversionThe extrusion quality shall be esti-mated by heat reversion method in accordance with 11.6.2.7.5 Flexural PropertiesFlexural modulus of elasticityvalues for the rounded pipe shall comply
23、 with Table 4 whentested in accordance with 11.7.8. Dimensions, Mass, and Permissible Variations8.1 Rounded Pipe DiameterThe average outside diameterof the rounded pipe shall meet the requirements given in Table5 with a tolerance of 61.0 % when measured in accordancewith 11.2.1.8.2 Rounded Pipe Wall
24、 ThicknessThe minimum wallthickness of the rounded pipe, when measured in accordancewith 11.2.2, shall not be less than the values specified in Table5.9. Workmanship, Finish, and Appearance9.1 The rounded and folded pipes shall be homogeneousthroughout and free from visible cracks, holes, foreign in
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF15042002STANDARDSPECIFICATIONFORFOLDEDPOLYVINYLCHLORIDEPVCPIPEFOREXISTINGSEWERANDCONDUITREHABILITATION

链接地址:http://www.mydoc123.com/p-535020.html