ASTM F1500-1998(2008) Standard Test Method for Quantitating Non-UV-Absorbing Nonvolatile Extractables from Microwave Susceptors Utilizing Solvents as Food Simulants《利用溶剂作为食品模拟物定性测定.pdf
《ASTM F1500-1998(2008) Standard Test Method for Quantitating Non-UV-Absorbing Nonvolatile Extractables from Microwave Susceptors Utilizing Solvents as Food Simulants《利用溶剂作为食品模拟物定性测定.pdf》由会员分享,可在线阅读,更多相关《ASTM F1500-1998(2008) Standard Test Method for Quantitating Non-UV-Absorbing Nonvolatile Extractables from Microwave Susceptors Utilizing Solvents as Food Simulants《利用溶剂作为食品模拟物定性测定.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1500 98 (Reapproved 2008)Standard Test Method forQuantitating Non-UV-Absorbing Nonvolatile Extractablesfrom Microwave Susceptors Utilizing Solvents as FoodSimulants1This standard is issued under the fixed designation F 1500; the number immediately following the designation indicates t
2、he year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method is applicable to complete microw
3、avesusceptors.1.2 This test method covers a procedure for quantitatingnon-UV-absorbing nonvolatile compounds which are extract-able when the microwave susceptor is tested under simulateduse conditions for a particular food product.1.3 The values stated in SI units are to be regarded asstandard. No o
4、ther units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility
5、 of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 260 Practice for Packed Column Gas ChromatographyE 682 Practice for Liquid Chromatography Terms and Re-lationshipsE 685 Practice for Testing Fixed-Wavelength PhotometricDetectors Used in Liquid ChromatographyF 874 T
6、est Method for Temperature Measurement and Pro-filing for Microwave SusceptorsF 1317 Test Method for Calibration of Microwave OvensF 1349 Test Method for Nonvolatile Ultraviolet (UV) Ab-sorbing Extractables from Microwave Susceptors3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1
7、.1 microwave susceptorpackaging materials that,when placed in a microwave field, are designed to interact withthe field and provide substantial heat to the package contents.3.1.2 nonvolatile extractablesthose chemical specieswhich released from microwave food packaging under simu-lated use condition
8、s and are detected using an applicablenonvolatile extractables method.4. Summary of Test Method4.1 Nonvolatile extractables are determined by subjecting asample of the susceptor material to microwave heating undersimulated use conditions. The sample is washed with solventscovering a range of polarit
9、ies. The solvent washes are com-bined and the solvents evaporated just to dryness. The residueis redissolved in a measured quantity of chloroform and thesample split for gravimetric or other analyses, such as HPLC orIR. For the gravimetric determination, a measured portion ofthe sample is filtered a
10、nd evaporated and the residue weighed.For other analyses, the remainder of the sample is evaporatedand may be reconstituted in dimethylacetamide prior to injec-tion (see Test Method F 1349 for quantitation of UV-absorbingnonvolatiles by HPLC), or treated appropriately prior toexamination by other ch
11、romatographic or spectroscopic meth-ods.5. Significance and Use5.1 This test method was developed to measure non-UV-absorbing nonvolatile extractables that may be present andmigrate from a microwave susceptor material during use. Itmay be a useful procedure to assist in minimizing the amountof non-U
12、V-absorbing nonvolatile extractables either throughsusceptor design or manufacturing processes.5.2 Supplementation of this procedure with other analyticaltechnologies such as high-pressure liquid chromatography,supercritical fluid chromatography, or infrared or other formsof spectroscopy may provide
13、 the analyst with additionalinformation regarding the identification of the components ofthe non-UV-absorbing nonvolatile extractables in the suscep-tor.1This test method is under the jurisdiction of ASTM Committee F02 on FlexibleBarrier Packaging and is the direct responsibility of Subcommittee F02
14、.15 onChemical/Safety Properties.Current edition approved Oct. 1, 2008. Published November 2008. Originallyapproved in 1994. Last previous edition approved in 2003 as F 1500 98(2003).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.
15、org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6. Apparatus and Reagents6.1 Microwave Oven, 700 6 35 W, no tur
16、ntable, calibratedin accordance with Test Method F 1317.6.2 Extraction Cell, Waldorf, described in Test MethodF 1349.NOTE 1If the cell is not equipped with a PTFE gasket, cut a gasketring to match the size of the sleeve from a116-in. PTFE sheet. Use of thegasket between the sleeve and the sample red
17、uces damage to the sample.6.3 Microwave Temperature Measurement System.6.4 Temperature Probe, high temperature.6.5 Beaker, 400-mL borosilicate glass.6.6 Hexane, analytical reagent grade or better.6.7 Acetonitrile, analytical reagent grade or better.6.8 Methylene Chloride, analytical reagent grade or
18、 better.6.9 Chloroform, analytical reagent grade or better.6.10 Dimethylacetamide, HPLC grade or better.6.11 Methanol, analytical reagent grade or better, dried overanhydrous sodium sulfate.6.12 Distilled Water.6.13 Nitrogen, grade suitable for solvent evaporation pur-poses.6.14 Rotary Evaporator, o
19、r equivalent.6.15 Weighing Boat, aluminum, formed by shaping alumi-num foil into a round boat approximately 1.5 cm in diameter.6.16 Filter, 0.45 m, compatible with chloroform.6.17 Round-Bottom Flask, 250 mL, with neck to fit rotaryevaporator.6.18 Vial,20mL.6.19 Heat Lamp, 125 W, or equivalent.6.20 B
20、oiling Stones.6.21 Watchglass, 8.5 or 9.0-cm diameter.7. Sampling7.1 The sample of microwave susceptor selected for extrac-tion should be representative of the entire susceptor.7.2 The sample should be undamaged, that is, laminationintact, uncreased (unless this is the normal configuration) andunalt
21、ered.7.3 Carefully cut a circular portion of the susceptor largeenough to fit the Waldorf cell with the top threaded sleeveremoved. Be sure the sample is cut large enough to fill theentire bottom of the cell. Carefully trim away any frayed edgesbefore testing.7.4 Preclean the susceptor to remove dus
22、t and fibers byblowing a stream of nitrogen over the surface for a fewseconds, or by gently brushing the surface with a camel hairbrush.8. Procedure8.1 Calibrate the microwave oven in accordance with TestMethod F 1317 to ensure that it is 700 6 35 W.8.2 Determine the sample test conditions by using
23、themethod for temperature profiling of microwave susceptors inuse in accordance with Test Method F 874.8.3 Place the precut susceptor sample into the bottomsection of the Waldorf cell. Carefully place the polytetrafluo-roethylene polymer (PTFE) gasket on top of the susceptor toprevent tearing when t
24、he cell sleeve is threaded in. Thread thetop sleeve of the cell into the bottom section of the cell,trapping the susceptor sample securely between the gasket andthe bottom of the cell.8.4 Carefully insert a temperature probe (6.4) through thesmall temperature probe port opening of the cell and ensur
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF150019982008STANDARDTESTMETHODFORQUANTITATINGNONUVABSORBINGNONVOLATILEEXTRACTABLESFROMMICROWAVESUSCEPTORSUTILIZINGSOLVENTSASFOODSIMULANTS

链接地址:http://www.mydoc123.com/p-535014.html