ASTM F1443-1993(2003) Standard Practice for Using 0 008-in (0 203-mm) Aperture Reflectometers as Test Instruments for Measuring Visual Image Quality of Business Copy Images《作为测量商业拷.pdf
《ASTM F1443-1993(2003) Standard Practice for Using 0 008-in (0 203-mm) Aperture Reflectometers as Test Instruments for Measuring Visual Image Quality of Business Copy Images《作为测量商业拷.pdf》由会员分享,可在线阅读,更多相关《ASTM F1443-1993(2003) Standard Practice for Using 0 008-in (0 203-mm) Aperture Reflectometers as Test Instruments for Measuring Visual Image Quality of Business Copy Images《作为测量商业拷.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1443 93 (Reapproved 2003)Standard Practice forUsing 0.008-in. (0.203-mm) Aperture Reflectometers as TestInstruments for Measuring Visual Image Quality of BusinessCopy Images1This standard is issued under the fixed designation F 1443; the number immediately following the designation in
2、dicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the use of the ref
3、lectance-typeoptical character testers with a 0.008-in. (0.203-mm) apertureas test instruments for measuring image quality.1.2 Although other systems may be available, this practicecovers two of the most commonly used instruments; theClearwave 082 Optical Character Tester2and the MacbethPrint Contra
4、st Meter.31.3 These instruments also have the capability of predictingmachine readability of documents. This practice does notaddress this capability.1.4 The values stated in inch-pound units are to be regardedas the standard. The SI units given in parentheses are forinformation only.1.5 This standa
5、rd does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 AST
6、M Standards:F 497 Practice for Use of the Electric Typewriter as a TestInstrument4F 597 Practice for Evaluation of One-Time Carbon Paper inCarbon-Interleaved Business Forms by Use of an ElectricTypewriter4F 686 Practice for Evaluation of Image Quality Produced bya Carbonless Copy Paper with an Elect
7、ric and ElectronicTypewriter4F 1033 Test Method for Comparing Lift-Off CorrectionMedia4F 1125 Terminology of Image Quality in Impact PrintingSystems4F 1174 Practice for Using a Personal Computer as a TestInstrument4F 1175 Practice for Using the Computer Impact Print-OutUnit as a Test Instrument for
8、Manifold Comparison43. Terminology3.1 DefinitionsRefer to Terminology F 1125 for defini-tions of terms applicable to this practice.4. Summary Of Practice4.1 This practice describes the use of small-aperture (0.008-in.) (0.203-mm) reflectance meters in evaluating business copyimages from any source i
9、ncluding but not limited to copiers,printers, typewriters, and facsimile machines. Image qualitycharacteristics common to all systems include reflectance,sharpness, cleanliness, and character width. Other characteris-tics may be evaluated depending on the imaging method.4.2 The 0.008-in. (0.203-mm)
10、optical character testersequipped with a one-to-one lens option have the ability toexamine large areas for average reflectance in the 13 modeand make measurements of small localized spots within theseareas in the 203 mode. The graduated projection viewingscreen allows accurate measurements of object
11、s within theviewing area in the 53 or 203 mode.4.3 Place the sample so that the image to be measured isover the 0.008-in. (0.203-mm) target area as observed on theviewing screen or in the viewing port. Reflectance values canbe read out directly on the digital meter. This capability may beused to mea
12、sure reflectance of printed characters, base paper,or areas in which characters have been corrected, or combina-tion thereof.4.4 Images for evaluation are produced by various systemsusing ASTM standards where available. When standards arenot available, knowledge of the imaging system and itscharacte
13、ristics should be applied. Although the test pattern1This practice is under the jurisdiction of ASTM Committee F05 on BusinessImaging Products and is the direct responsibility of Subcommittee F05.03onResearch.Current edition approved April 15, 1993. Published August 1993. Originallypublished as F 14
14、43 92. Last previous edition F 1443 92.2Formerly manufactured by Moore, this tester is currently available fromClearwave Inc., 8701 Buffalo Ave., Niagara Falls, NY 14304.3Available from Macbeth, Division of Kollmorgen Instruments Corp., 405 LittleBritain Rd., New Windsor, NY 12553-6148.4Annual Book
15、of ASTM Standards, Vol 15.09.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.used will depend on the ASTM standard being used, a typicalpattern is shown in Fig. 1.5. Significance and Use5.1 This practice enables image quality evaluat
16、ion onsamples generated by various imaging systems. It can be usedto conduct investigations, including image reflectance, sharp-ness, voids, character width, and degradation of materials. Thetest instruments can be used for research and developmentprojects as well as for manufacturing control.6. Int
17、erferences6.1 Variations in paper surfaces and thickness will affectsome print quality parameters. If sheeted paper is used, the usershould be aware that sheet to sheet smoothness and brightnessvariations within a ream may have a significant effect, particu-larly on reflectance readings. Most papers
18、 contain a felt and awire side that have different surface smoothness levels and thisin turn can also affect test results.6.2 The frequency between calibration may affect reflec-tance readings. The use of a voltage regulator for those nothaving one built in will minimize drift and eliminate variatio
19、nsin line voltage which could affect reflectance measurements.6.3 Evaluation equipment cleanliness is important for accu-rate readings. Users should follow manufacturers recom-mended cleaning procedures.6.4 Imaging system used, and the various settings on it canaffect the results.6.5 Differences in
20、the skill level of the tester and differencesbetween instruments may affect the measurements.6.6 Some reflectance type optical character testers containoptical filters. The spectral response of filters can change withtime. Although the calibration procedure guarantees calibrationwhen reading black/w
21、hite images, it does not on coloredimages.6.7 Heat generated by the lamps of both the 082A2andPCM II3can damage samples that contain thermally sensitivematerials such as direct thermal paper and samples employingtoners for the image. Reflectance readings can be taken butcare must be employed to prev
22、ent damage or alteration to thesamples during the measurement.6.8 Care must be maintained when moving the imagedspecimen on the instrument, so as not to mar the image.7. Apparatus and Materials7.1 Clearwave Optical Character Tester:7.1.1 Clearwave 082A,5with the 203 magnification andone-to-one lens
23、options (see Fig. 2),7.1.2 Voltage Regulator (115 or 230 V), for the availableline voltage (optional), and7.1.3 Barium Sulfate Calibration Standard and White Ce-ramic Tile.7.2 Macbeth Print Contrast Meter:7.2.1 Macbeth PCM II6(see Fig. 3), and7.2.2 Barium Sulfate Calibration Standard.8. Test Specime
24、ns8.1 Prepare the test specimens using the procedure outlinedin 10.2 for the imaging system. A type font should be selectedso the 0.008-in. (0.203-mm) aperture area will fit within theprinted character boundaries.8.2 Generate the test specimen in accordance with theinstructions given in the test pro
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF144319932003STANDARDPRACTICEFORUSING0008IN0203MMAPERTUREREFLECTOMETERSASTESTINSTRUMENTSFORMEASURINGVISUALIMAGEQUALITYOFBUSINESSCOPYIMAGES

链接地址:http://www.mydoc123.com/p-534893.html