1、Designation: F1416 96 (Reapproved 2014)Standard Guide forSelection of Time-Temperature Indicators1This standard is issued under the fixed designation F1416; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide covers information on the selection ofcommercially available time-temperature indicators (TTIs) fornoninvasive external p
3、ackage use on perishable products, suchas food and pharmaceuticals. When attached to the package ofa perishable product, TTIs are used to measure the combinedtime and temperature history of the product in order to predictthe remaining shelf life of the product or to signal the end of itsusable shelf
4、 life. It is the responsibility of the processor of theperishable product to determine the shelf life of a product at theappropriate temperatures and to consult with the indicatormanufacturer to select the available indicator which mostclosely matches the quality of the product as a function of time
5、and temperature.NOTE 1Besides time-temperature indicator, TTI is also an abbrevia-tion for time-temperature monitor and time-temperature integrator.1.2 Time-temperature indicators may be integrated into aHazard Analysis and Critical Control Point (HACCP) plan.Appropriate instructions should be estab
6、lished for handlingproducts for which either the indicator has signaled the end ofusable shelf life or the shelf life of the product at its normalstorage temperature has been reached.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is there
7、sponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Terminology2.1 Definitions:2.1.1 activation energythe quantity commonly used todescribe the dependence of the shelf life of a pro
8、duct (or therate of a reaction) on temperature, as given by the Arrheniusrelationship.2.1.1.1 DiscussionThe higher the activation energy, themore the shelf life of a product changes with temperature. Ifthe shelf life of a product is known at two temperatures, theactivation energy is given by the fol
9、lowing formula:Ea5lnLIFE1/LIFE2!1T121T23 R (1)where LIFE1and LIFE2= shelf lives at temperaturesT1and T2.2.1.2 all-temperature time-temperature indicator a TTIthat continues to change at some rate at all temperatures.2.1.3 Arrhenius plota plot of the logarithm of the shelf lifeof a product versus the
10、 reciprocal of temperature (1T).2.1.3.1 DiscussionIf the shelf life of a product exhibitsArrhenius behavior, then an Arrhenius plot of the shelf life willbe a straight line. The activation energy of the shelf life is equalto the slope of the line times R (see 2.1.1.1). It is more accurateto use a re
11、gression analysis to determine the slope based on thedata from at least three temperatures than to use only twopoints as in the previous equation. A blank Arrhenius plot isshown in Fig. 1. The plot axes are the log10of the shelf life andthe reciprocal of temperature. For ease of use, the Fahrenheita
12、nd Celsius temperatures are shown on the graph instead of theinverse temperature.2.1.4 Arrhenius relationshipa relationship that describesthe dependence of the rate of a chemical reaction on tempera-ture as follows:k 5 A0e 2SEaRTD(2)where:k = rate constant,A0= constant with the same time units as k,
13、T = temperature, K (C + 273), andR = universal gas constant.When R = 0.001987 kcal/(mol deg), the activation energy,Ea, is given in units of kcal/mol.When R = 0.00831 kJ/(mol deg), the activation energy, Ea,is given in units of kJ/mol.2.1.4.1 DiscussionThis relationship also describes the de-pendenc
14、e of the shelf life of many TTIs and perishableproducts on the effective average temperature to which they areexposed. Since the shelf life is the time for the reaction to1This guide is under the jurisdiction of ASTM Committee F02 on FlexibleBarrier Packaging and is the direct responsibility of Subc
15、ommittee F02.15 onChemical/Safety Properties.Current edition approved April 1, 2014. Published April 2014. Originallyapproved in 1996. Last previous edition approved in 2008 as F1416 96(2008).DOI: 10.1520/F1416-96R14.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken
16、, PA 19428-2959. United States1proceed to a specific extent, theArrhenius relationship for shelflife is given by the following formula:LIFE 5 BeSEaRTD(3)where B = constant with the same time units as LIFE.2.1.5 dual function time-temperature indicator a TTI thatcombines both all-temperature and thre
17、shold-temperatureresponses, overlaid in a single indicator in order to modify thetotal time-temperature response.2.1.6 effective average temperaturethe single constanttemperature that would have the same effect on the shelf life ofa product as the actual temperature profile has for the sametime peri
18、od.2.1.7 hazard analysis and critical control points(HACCP)a method to control food quality and safety byidentifying and controlling those processing and distributionsteps where a food safety hazard may be prevented, eliminated,or reduced to acceptable levels.2.1.8 shelf lifethe time required for va
19、rious changes to aproduct to accumulate to the point where the product no longermeets predetermined criteria and is no longer consideredsuitable for its original purpose.2.1.8.1 DiscussionIn some cases, such as where patho-genic microbial growth is involved, there may be a serioushealth risk in usin
20、g a product past its shelf life. In such cases,the shelf life to be monitored should be conservative enough sothat its expiration is signaled well before a health concerndevelops. It may be desirable to indicate even short occur-rences of undesirably high temperatures. Other changes mayalso occur, s
21、uch as in color, texture, or rancidity, which rendera product unacceptable for its original use. For most perishableproducts, the shelf life decreases with increasing temperature.2.1.9 threshold-temperature time-temperature indicatoraTTI that only changes at temperatures above a specific thresh-old.
22、2.1.10 time-temperature indicator (TTI)a device that canbe affixed to the package of a perishable product and thatexhibits a change in a physically measurable or visuallymeasurable property as a combined function of both time andtemperature. For example, properties that change include color,light re
23、flectance, or a moving boundary between two colors.2.1.11 time-temperature integratorsee time-temperatureindicator.2.1.11.1 DiscussionThis term emphasizes the fact that theindicators response is an integration of the effects of both timeand temperature.2.1.12 time-temperature monitorsee time-tempera
24、ture in-dicator.2.2 Definitions of Terms Specific to This Standard:2.2.1 activation methodthe method by which an inactiveTTI is changed to an active state.2.2.1.1 DiscussionThis may include a physical activationmethod, such as removing or breaking a barrier, or may requireraising the temperature to
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF141619962014STANDARDGUIDEFORSELECTIONOFTIMETEMPERATUREINDICATORS 时间 温度 指示器 选择 标准 指南 PDF

链接地址:http://www.mydoc123.com/p-534840.html