ASTM F1092-2004(2010) Standard Specification for Fiberglass (GRP) Pultruded Open-Weather Storm and Guard Square Railing Systems《玻璃纤维挤拔制露天防风暴和方型护栏设备的标准规范》.pdf
《ASTM F1092-2004(2010) Standard Specification for Fiberglass (GRP) Pultruded Open-Weather Storm and Guard Square Railing Systems《玻璃纤维挤拔制露天防风暴和方型护栏设备的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1092-2004(2010) Standard Specification for Fiberglass (GRP) Pultruded Open-Weather Storm and Guard Square Railing Systems《玻璃纤维挤拔制露天防风暴和方型护栏设备的标准规范》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F1092 04 (Reapproved 2010)An American National StandardStandard Specification forFiberglass (GRP) Pultruded Open-Weather Storm andGuard, Square Railing Systems1This standard is issued under the fixed designation F1092; the number immediately following the designation indicates the year
2、oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification provides the material requirements,con
3、struction, installation, and testing requirements for open-weather deck, storm-and-guard, fiberglass square railing sys-tems. Components are to be manufactured by the pultrusionprocess.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathem
4、aticalconversions to SI units that are provided for information onlyand are not considered standard.1.3 The following safety hazards caveat pertains only to thetest methods portion, Section 9, of this specification: Thisstandard does not purport to address all of the safety concerns,if any, associat
5、ed with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:2D570 Test Method for Water Absorption of PlasticsD638 Test Meth
6、od for Tensile Properties of PlasticsD695 Test Method for Compressive Properties of RigidPlasticsD790 Test Methods for Flexural Properties of Unreinforcedand Reinforced Plastics and Electrical Insulating MaterialsD792 Test Methods for Density and Specific Gravity (Rela-tive Density) of Plastics by D
7、isplacementD3846 Test Method for In-Plane Shear Strength of Rein-forced PlasticsD3917 Specification for Dimensional Tolerance of Thermo-setting Glass-Reinforced Plastic Pultruded ShapesE84 Test Method for Surface Burning Characteristics ofBuilding Materials3. Terminology Definition3.1 pultrusionproc
8、ess of pulling fiberglass rovings(strands), mats, and other forms of reinforcements such aswoven fiberglass through baths of thermosetting liquid resin,and then through a heated forming die (made of steel) to forma completed composite fiberglass structural shape.3.1.1 DiscussionThe heated die causes
9、 a chemical reac-tion to be initiated in the resin. The liquid resin molecules willcross-link and develop into a hardened plastic that is reinforcedwith the fiberglass.4. Classification4.1 Handrails and stanchions shall be fiberglass pultrudedsquare tube available in the following two types:4.1.1 Ty
10、pe 1FThree-course railing systems, for use alongthe exposed peripheries of freeboards, weather decks, andsuperstructure decks.4.1.2 Type 2FTwo-course railing systems, for use onbridges, platforms, walkways, and elsewhere as needed.5. Ordering Information5.1 Orders for materials under this specificat
11、ion shall in-clude the following information:5.1.1 Quantity (lineal feet (metres) of railing system).5.1.2 Name of material (fiberglass pultruded square railingsystem).5.1.3 Type (See 4.1).5.1.4 Fiberglass coaming, if specified (lineal feet (metres).(See 6.2.5).5.1.5 Attachment method for stanchions
12、 (see 6.2.6).5.1.6 ASTM designation and year of issue.6. Materials and Manufacture6.1 Materials:6.1.1 The fiberglass (GRP) pultruded square tube shall be 23 2 314 in. (50 3 50 3 6.4 mm) with the outside cornerradius532 in. (4 mm). A synthetic surface veil shall be theoutermost layer of reinforcement
13、 covering the entire exteriorsurface. The resin used throughout the part shall be either a1This specification is under the jurisdiction of ASTM Committee F25 on Shipsand Marine Technology and is the direct responsibility of Subcommittee F25.03 onOutfitting and Deck Machinery.Current edition approved
14、 May 1, 2010. Published June 2010. Originallyapproved in 1987. Last previous edition approved in 2004 as F1092 04. DOI:10.1520/F1092-04R10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume
15、 information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.flame retardant isophthalic polyester or a flame retardant vinylester resin containing an ultra-violet radi
16、ation (UV) inhibitor.The fiberglass pultruded square tube shall achieve a flamespread index of 25 or less rating in accordance with TestMethod E84. In addition, the fiberglass pultruded square tubeshall achieve a smoke developed index of 450 or less. Theexterior of the pultruded square tubing shall
17、havea1mil(0.025 mm) minimum polyurethane protective coating foradded ultraviolet protection. The fiberglass pultruded squaretubing shall meet the properties specified in Table 1 anddimensional tolerances shall be in accordance with Specifica-tion D3917.6.1.2 Fiberglass sheet or solid fiberglass bar
18、shall be used tofabricate the internal connectors for the square tube. Theinternal connectors will be 112 3 112 in. (38.1 3 38.1 mm)with length and angularity variable to meet the requirements ofeach connection. Angular connections shall be fabricated fromfiberglass sheet bonded together using a bis
19、phenolA/epichlorohydrin epoxy resin with an amine curing agent togive a minimum thickness of 112 in. (38.1 mm). The angularconnections will be fabricated to the proper dimension from thefiberglass sheets that have been bonded together. Fiberglasssheet used for angular connections shall meet the prop
20、ertiesspecified in Table 1. Fiberglass solid bar, 112 3 112 in. (38.1 338.1 mm), shall be used for the straight connections and shallmeet the properties specified in Table 1.6.1.3 Rivets shall be nickel copper or nonmetallic.6.1.4 Bolts shall be12 in. (12.7 mm) diameter, 316 stainlesssteel.6.1.5 Adh
21、esive used to bond internal connectors to fiber-glass pultruded square tube shall be a bisphenolA/epichlorohydrin epoxy resin with an amine curing agent.6.2 Manufacture:6.2.1 There shall be a minimum clearance of 4 in. (101 mm)between rail or stanchion centerline and other structure exceptwhere a di
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF109220042010STANDARDSPECIFICATIONFORFIBERGLASSGRPPULTRUDEDOPENWEATHERSTORMANDGUARDSQUARERAILINGSYSTEMS

链接地址:http://www.mydoc123.com/p-534164.html