ASTM F1042-1987(2004) Standard Practice for Estimating Toner and Dispersant Usage in Copiers Utilizing Liquid Developers《评定复印机超荷液体显影剂中的调色剂和分散剂》.pdf
《ASTM F1042-1987(2004) Standard Practice for Estimating Toner and Dispersant Usage in Copiers Utilizing Liquid Developers《评定复印机超荷液体显影剂中的调色剂和分散剂》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1042-1987(2004) Standard Practice for Estimating Toner and Dispersant Usage in Copiers Utilizing Liquid Developers《评定复印机超荷液体显影剂中的调色剂和分散剂》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1042 87 (Reapproved 2004)Standard Practice forEstimating Toner and Dispersant Usage in Copiers UtilizingLiquid Developers1This standard is issued under the fixed designation F 1042; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、 of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice describes a procedure for estimating thenumber of copies that can be produced
3、 for a given unit of toner,and a given unit of dispersant in a copier utilizing liquiddeveloper.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health p
4、ractices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F 335 Terminology Relating to Electrostatic CopyingF 596 Practice for Comparative Evaluation of the ImagingProperties of Dry Electrostatic TonersF 875 Test Method for Evaluatio
5、n of Large Area Densityand Background on Office CopiersF 995 Test Method for Estimating Toner Usage in CopiersUtilizing Dry Two-Component Developer3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 dispersantan organic liquid in a liquid developersystem that conveys toner particl
6、es. (See Terminology F 335.)3.1.2 dispersant usageamount of dispersant (milligramsper copy) removed from the system during the copyingprocess.3.1.3 liquid tonera toner dispersed in an organic liquidcarrier used for developing electrostatic images in copiers.3.1.4 toner usageamount of toner (milligra
7、ms per copy)removed from the system during the copying process.4. Summary of Practice4.1 A copier is set up to standard operating parameters andoperated under a controlled job stream and environment for alength of time sufficient for stable performance. A known orestimated quantity of toner and disp
8、ersant used to replenish thetoner bath over the length of the test, along with the totalnumber of copies generated, is used to estimate the number ofcopies produced per unit of toner and per unit of dispersant.5. Significance and Use5.1 This practice can be used to evaluate the performance ofdiffere
9、nt lots of toner in a common machine. It can also be usedto evaluate the economics of toner and dispersant usage whenmaking machine-to-machine comparisons.5.2 This practice provides only a point estimate that issubject to a significant number of variables that are not easilymeasured. Those making de
10、cisions based on the results of thispractice should carefully consider the accuracy of the resultsand other pertinent data.5.3 Actual use of the copier in normal operating conditionswill most likely result in toner and dispersant usage valuesdifferent from those generated using this practice.6. Inte
11、rferences6.1 Variations in toner usage can occur for many of thefollowing reasons: machine adjustments, operating environ-ment, varying use of special copy controls, number of copieson photoconductor and toner bath, variations in copy paper,operator variability, batch-to-batch toner variability, mac
12、hine-to-machine variability, and use of different area of coverage oforiginal documents.6.2 Machine-to-machine comparisons should be made, ifpossible, with the same manufacturing lot of toner and dispers-ant.6.3 The test conditions used when making comparisonsbetween machines or toners should be car
13、efully considered andwell documented.6.4 The test must be controlled as described in this practice.A casual use of the copier during the test may affect the results.1This practice is under the jurisdiction of ASTM Committee F05 on BusinessCopy Products and is the direct responsibility of Subcommitte
14、e F05.04 onElectrostatic Copy Products.Current edition approved May 15, 1987. Published July 1987.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Docu
15、ment Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.5 The toner and dispersant usage estimated with thispractice may not accurately predict actual field results. Actualresults will depend not only o
16、n those listed in 6.1 but on anumber of additional variables: type of originals used (percentarea of coverage), machine and service variability, users imagequality requirements, and number of copies per original.7. Apparatus7.1 Refer to Test Method F 875 for required instruments.7.2 Balance, reading
17、 to the nearest tenth of a gram.8. Reagents and Materials8.1 Sufficient quantities of paper, toner, dispersant andphotoconductor, to run the evaluation. (See 10.7.)8.2 Test Targets:8.2.1 Chart for 4 % CoverageAs shown in Fig. 1 of TestMethod F 995.38.2.2 Chart for 8 % CoverageAs shown in Fig. 2 of T
18、estMethod F 995.38.2.3 Density and Background Test SheetAs shown inFig. 1 of Test Method F 875.49. Conditioning9.1 Condition the paper, toner, dispersant, photoconductor,and copier in the test environment for 24 h prior to initiatingthe test.10. Procedure10.1 Control the environment in which the fol
19、lowing pro-cedure is carried out to reduce variation. Control the tempera-ture6 5F (62.75C) around the mean temperature selectedfor the test. Control the relative humidity (RH) 610 % aroundthe mean RH selected for this test. Measure and record theactual temperature and RH periodically during the tes
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF104219872004STANDARDPRACTICEFORESTIMATINGTONERANDDISPERSANTUSAGEINCOPIERSUTILIZINGLIQUIDDEVELOPERS

链接地址:http://www.mydoc123.com/p-534022.html