ASTM E999-2010 0000 Standard Guide for Controlling the Quality of Industrial Radiographic Film Processing《工业射线摄影胶片加工的质量控制的标准指南》.pdf
《ASTM E999-2010 0000 Standard Guide for Controlling the Quality of Industrial Radiographic Film Processing《工业射线摄影胶片加工的质量控制的标准指南》.pdf》由会员分享,可在线阅读,更多相关《ASTM E999-2010 0000 Standard Guide for Controlling the Quality of Industrial Radiographic Film Processing《工业射线摄影胶片加工的质量控制的标准指南》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E999 10Standard Guide forControlling the Quality of Industrial Radiographic FilmProcessing1This standard is issued under the fixed designation E999; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi
2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This guide2establishes guidelines that may be used forthe control and maintenance of industrial radiographic filmprocessing equ
3、ipment and materials. Effective use of theseguidelines aid in controlling the consistency and quality ofindustrial radiographic film processing.1.2 Use of this guide is limited to the processing of films forindustrial radiography. This guide includes procedures forwet-chemical processes and dry proc
4、essing techniques.1.3 The necessity of applying specific control proceduressuch as those described in this guide is dependent, to a certainextent, on the degree to which a facility adheres to goodprocessing practices as a matter of routine procedure.1.4 If a nondestructive testing agency as describe
5、d inPractice E543 is used to perform the examination, the testingagency shall meet the requirements of Practice E543.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priat
6、e safety, health, and environmental practices and deter-mine the applicability of federal and local codes prior to use.2. Referenced Documents2.1 ASTM Standards:3E94 Guide for Radiographic ExaminationE543 Specification for Agencies Performing Nondestruc-tive TestingE1079 Practice for Calibration of
7、Transmission Densitom-etersE1254 Guide for Storage of Radiographs and UnexposedIndustrial Radiographic FilmsE1316 Terminology for Nondestructive Examinations2.2 ISO Standards:4ISO 11699-2 Nondestructive testingIndustrial Radio-graphic Film. Part 2: Control of film processing by meansof references va
8、lues.ISO 18917 PhotographyDetermination of residual thio-sulfate and other related chemicals in processed photo-graphic materialsMethods using iodine amylase, meth-ylene blue, and silver sulfide2.3 CEN Standards:EN 584-2 Nondestructive TestingIndustrial RadiographicFilm. Part 2: Control of film proc
9、essing by means ofreference values42.4 ANSI Standards:IT 2.26 PhotographyPhotographic Materials Determina-tion of Safelight Conditions43. Terminology3.1 DefinitionsFor definitions of terms used in this guide,see Terminology E1316.4. Significance and Use4.1 The provisions in this guide are intended t
10、o control thereliability or quality of the image development process only.The acceptability or quality of industrial radiographic filmsprocessed in this manner as well as the materials or productsradiographed remain at the discretion of the user, or inspector,or both. It is further intended that thi
11、s guide be used as anadjunct to and not a replacement for Guide E94.5. Chemical Mixing for Manual and Automatic Processes5.1 Any equipment that comes in contact with processingsolutions should be made of glass, hard rubber, polyethylene,PVC, enameled steel, stainless steel, or other chemically inert
12、materials. This includes materials such as plumbing, mixingimpellers, and the cores of filter cartridges. Do not allowmaterials such as tin, copper, steel, brass, aluminum, or zinc tocome into contact with processing solutions. These materialscan cause solution contamination that may result in filmf
13、ogging or rapid oxidation.5.2 Mixing Chemicals:1This guide is under the jurisdiction of ASTM Committee E07 on Nondestruc-tive Testing and is the direct responsibility of Subcommittee E07.01 on Radiology(X and Gamma) Method.Current edition approved June 1, 2010. Published July 2010. Originally approv
14、edin 1990. Last previous edition approved in 2005 as E999 - 05. DOI: 10.1520/E0999-10.2For ASME Boiler and Pressure Vessel Code applications see related Specifi-cation SE-999 in Section II of that Code.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Serv
15、ice at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.4Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.1Copyright ASTM International, 1
16、00 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2.1 Do not mix powdered chemicals in processor tanks,since undissolved particles may be left in the square corners ofthe tank. Mix solutions in separate containers made frommaterials specified in 5.1.5.2.2 Carefully
17、 follow the manufacturers package direc-tions or formulas for mixing the chemicals. Start with thecorrect volume of water at the temperature specified in theinstructions, and add chemicals in the order listed. During themixing and use of radiographic film processing chemicals, besure to observe all
18、precautionary information on chemicalcontainers and in instructions.5.2.3 Proper mixing of chemicals can be verified withmeasurements of pH and specific gravity.5.3 Contamination of Solutions:5.3.1 Thoroughly clean all mixing equipment immediatelyafter use to avoid contamination when the next soluti
19、on ismixed. When mixing fixer from powder, make sure to add thepowder carefully to the water in the mixing tank so fixer dustdoes not get into other processing solutions. When mixing anychemical, protect nearby tank solutions with floating lids anddust covers. The use of a vent hood is recommended a
20、s a safetyprecaution.5.3.2 The water supply should either be de-ionized orfiltered to 50 microns or better, so it is clean and sediment-free.5.3.3 If large tanks are used for mixing, carefully mark thevolume levels to be certain that volumes are correct.5.3.4 Use separate mixers for developer soluti
21、on and forfixer solution. If only one mixer is available, thoroughly rinsethe mixer after each mix to avoid cross-contamination ofchemicals. Use of impeller-type mixers provides rapid, thor-ough mixing. When positioning the impeller special cautionshould be taken in choosing angle and depth to minim
22、ize theamount of air being drawn into the solution. Over-mixing ofthe solutions can cause oxidation, especially with developers,and should be avoided. Rinse the shaft, impeller, and mountingclamp with water after use.5.4 Maintaining Equipment:5.4.1 Immediately clean all mixing equipment after use.5.
23、4.2 In addition to cleaning equipment immediately afteruse, wash any mixing apparatus that has been idle for a longperiod of time to eliminate dust and dirt that may haveaccumulated.5.4.3 Processing hangers and tanks should be free of corro-sion and chemical deposits. Encrusted deposits that accumul
24、atein tanks, trays, and processing equipment which are difficult toremove by conventional cleaning, can be removed by using thespecially formulated cleaning agents recommended by thechemical or equipment manufacturer.6. Storage of Solutions6.1 In Original ContainersFollow the manufacturersstorage an
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME99920100000STANDARDGUIDEFORCONTROLLINGTHEQUALITYOFINDUSTRIALRADIOGRAPHICFILMPROCESSING 工业 射线 摄影

链接地址:http://www.mydoc123.com/p-533936.html