ASTM E970-2007 Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source《用辐射热能源测量暴露屋顶层绝缘材料临界辐射通量用标准试验方法》.pdf
《ASTM E970-2007 Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source《用辐射热能源测量暴露屋顶层绝缘材料临界辐射通量用标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E970-2007 Standard Test Method for Critical Radiant Flux of Exposed Attic Floor Insulation Using a Radiant Heat Energy Source《用辐射热能源测量暴露屋顶层绝缘材料临界辐射通量用标准试验方法》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 970 07An American National StandardStandard Test Method forCritical Radiant Flux of Exposed Attic Floor Insulation Usinga Radiant Heat Energy Source1This standard is issued under the fixed designation E 970; the number immediately following the designation indicates the year oforigina
2、l adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This fire-test-response standard describes a procedurefor measuri
3、ng the critical radiant flux of exposed attic floorinsulation subjected to a flaming ignition source in a gradedradiant heat energy environment in a test chamber. Thespecimen is any attic floor insulation. This test method is notapplicable to those insulations that melt or shrink away whenexposed to
4、 the radiant heat energy environment or the pilotburner.1.2 This fire-test-response standard measures the criticalradiant flux at the point at which the flame advances thefarthest. It provides a basis for estimating one aspect of fireexposure behavior for exposed attic floor insulation. Theimposed r
5、adiant flux simulates the thermal radiation levelslikely to impinge on the floors of attics whose upper surfacesare heated by the sun through the roof or by flames from anincidental fire in the attic. This fire-test-response standard wasdeveloped to simulate an important fire exposure component offi
6、res that develop in attics, but is not intended for use inestimating flame spread behavior of insulation installed otherthan on the attic floor.1.3 The values stated in SI units are to be regarded asstandard. The values given in parentheses are for informationonly.1.4 The text of this standard refer
7、ences notes and footnotesthat provide explanatory information. These notes and foot-notes, excluding those in tables and figures, shall not beconsidered as requirements of this standard.1.5 This standard is used to measure and describe theresponse of materials, products, or assemblies to heat andfla
8、me under controlled conditions, but does not by itselfincorporate all factors required for fire hazard or fire riskassessment of the materials, products, or assemblies underactual fire conditions.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use
9、. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.7 The text of this standard references notes and footnoteswhich provide explanatory material. These notes and footnot
10、es(excluding those in tables and figures) shall not be consideredas requirements of the standard.2. Referenced Documents2.1 ASTM Standards:2C 665 Specification for Mineral-Fiber Blanket Thermal In-sulation for Light Frame Construction and ManufacturedHousingC 764 Specification for Mineral Fiber Loos
11、e-Fill ThermalInsulationE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE 122 Practice for Calculating Sample Size to Estimate,With a Specified Tolerable Error, the Average for aCharacteristic of a Lot or ProcessE 176 Terminology of Fire StandardsE 631 Terminology of Building
12、 ConstructionsE 648 Test Method for Critical Radiant Flux of Floor-Covering Systems Using a Radiant Heat Energy Source2.2 Federal Specifications:HH-I-515 Insulation Thermal (Loose Fill for Pneumatic orPoured Application), Cellulosic or Wood Fiber3HH-I-521, Insulation Blankets, Thermal (Mineral Fiber
13、, forAmbient Temperature)3HH-I-1030 Insulation, Thermal (Mineral Fiber, for Pneu-matic or Poured Application)33. Terminology3.1 For definitions of terms used in this test method andassociated with fire issues refer to the terminology contained inTerminology E 176.3.2 Definition:1This test method is
14、under the jurisdiction of ASTM Committee E05 on FireStandards and is the direct responsibility of Subcommittee E05.22 on SurfaceBurning.Current edition approved July 1, 2007. Published August 2007. Originallyapproved in 1983. Last previous edition approved in 2000 as E 970 00.2For referenced ASTM st
15、andards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from Standardization Documents Order Desk, DODSSP, Bldg. 4,Section D, 700
16、 Robbins Ave., Philadelphia, PA 19111-5098, http:/www.dodssp.daps.mil.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.2.1 attic, nan accessible enclosed space in a buildingimmediately below the roof and wholly or partly within ther
17、oof framing.3.2.2 See Terminology E 631 for additional definitions ofterms used in this test method.3.3 Definitions of Terms Specific to This Standard:3.3.1 critical radiant flux, nthe level of incident radiantheat energy on the attic floor insulation system at the mostdistant flame-out point. It is
18、 reported as W/cm2(or Btu/ft2s).3.3.2 radiant flux profile, nthe graph relating incidentradiant heat energy on the specimen plane to distance from thepoint of initiation of flaming ignition, that is, 0 mm.3.3.3 total flux metre, nthe instrument used to measure thelevel of radiant heat energy inciden
19、t on the specimen plane atany point.4. Summary of Test Method4.1 A horizontally mounted insulation specimen is exposedto the heat from an air-gas radiant heat energy panel locatedabove and inclined at 30 6 5 to the specimen. After a shortpreheat, the hottest end of the specimen is ignited with a sma
20、llcalibrated flame. The distance to the farthest advance offlaming is measured, converted to kilowatts per square meterfrom a previously prepared radiant flux profile graph, andreported as the critical radiant flux.5. Significance and Use5.1 This fire-test-response standard is designed to provide ab
21、asis for estimating one aspect of the fire exposure behavior toexposed insulation installed on the floors of building attics. Thetest environment is intended to simulate conditions that havebeen observed and defined in full-scale attic experiments.5.2 The test is intended to be suitable for regulato
22、ry statutes,specification acceptance, design purposes, or development andresearch.5.3 The fundamental assumption inherent in the test is thatcritical radiant flux is one measure of the surface burningcharacteristics of exposed insulation on floors or between joistsof attics.5.4 The test is applicabl
23、e to attic floor insulation specimensthat follow or simulate accepted installation practice.5.5 In this procedure, the specimens are subjected to one ormore specific sets of laboratory fire test exposure conditions. Ifdifferent test conditions are substituted or the anticipatedend-use conditions are
24、 changed, caution should be used topredict changes in the performance characteristics measured byor from this test. Therefore, the results are strictly valid onlyfor the fire test exposure conditions described in this procedure.5.5.1 If the test results obtained by this test method are to beconsider
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME9702007STANDARDTESTMETHODFORCRITICALRADIANTFLUXOFEXPOSEDATTICFLOORINSULATIONUSINGARADIANTHEATENERGYSOURCE

链接地址:http://www.mydoc123.com/p-533872.html