ASTM E878-2011 3125 Standard Test Method for Determination of Titanium in Iron Ores and Related Materials by Diantipyrylmethane Ultraviolet Spectrometry 《用二安替比林基甲烷紫外分光法测定铁矿石和相关材料中钛.pdf
《ASTM E878-2011 3125 Standard Test Method for Determination of Titanium in Iron Ores and Related Materials by Diantipyrylmethane Ultraviolet Spectrometry 《用二安替比林基甲烷紫外分光法测定铁矿石和相关材料中钛.pdf》由会员分享,可在线阅读,更多相关《ASTM E878-2011 3125 Standard Test Method for Determination of Titanium in Iron Ores and Related Materials by Diantipyrylmethane Ultraviolet Spectrometry 《用二安替比林基甲烷紫外分光法测定铁矿石和相关材料中钛.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E878 11Standard Test Method forDetermination of Titanium in Iron Ores and RelatedMaterials by Diantipyrylmethane Ultraviolet Spectrometry1This standard is issued under the fixed designation E878; the number immediately following the designation indicates the year oforiginal adoption or,
2、 in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of titanium iniron ores, concentrates,
3、 and agglomerates in the compositionalrange from 0.01 % to 6.0 % titanium.NOTE 1As used in this test method (except as related to the termrelative standard deviation), percent or “%” refers to mass fraction(wt/wt) of the form g/100g.1.2 The values stated in SI units are to be regarded asstandard. No
4、 other units of measurement are included in thisstandard.1.3 This test method has been evaluated in accordance withPractice E1601 and Guide E1763. Unless otherwise noted in13, the lower limit in the scope of each method specifies thelowest analyte content that may be analyzed with acceptableerror (d
5、efined as a nominal 5 % risk of obtaining a 50 % orlarger relative difference in results on the same test sample intwo laboratories).1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to estab
6、lish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D1193 Specification for Reagent WaterE50 Practices for Apparatus, Reagents, and Safety Consid-erations for Chemical Analysis of Metals, Ore
7、s, andRelated MaterialsE135 Terminology Relating to Analytical Chemistry forMetals, Ores, and Related MaterialsE877 Practice for Sampling and Sample Preparation of IronOres and Related Materials for Determination of ChemicalCompositionE882 Guide for Accountability and Quality Control in theChemical
8、Analysis LaboratoryE1601 Practice for Conducting an Interlaboratory Study toEvaluate the Performance of an Analytical MethodE1763 Guide for Interpretation and Use of Results fromInterlaboratory Testing of Chemical Analysis Methods3. Terminology3.1 For definitions of terms used in this test method, r
9、efer toTerminology E135.4. Summary of Test Method4.1 The sample is decomposed by treatment with hydro-chloric, nitric, and sulfuric acids, or by sintering with sodiumperoxide, or by fusion with sodium tetraborate and sodiumcarbonate. Iron is reduced in an acid medium with ascorbicacid, the color is
10、developed with diantipyrylmethane, and theabsorbance is measured at approximately 385 nm.5. Significance and Use5.1 This test method is intended to be used for compliancewith compositional specifications for titanium content. It isassumed that all who use these procedures will be trainedanalysts cap
11、able of performing common laboratory proceduresskillfully and safely. It is expected that work will be performedin a properly equipped laboratory and that proper wastedisposal procedures will be followed. Appropriate qualitycontrol practices must be followed such as those described inGuide E882.6. I
12、nterferences6.1 None of the elements normally found in iron oresinterfere.7. Reagents and Materials7.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents conform to the specifications of the Committee on1This test method i
13、s under the jurisdiction of ASTM Committee E01 onAnalytical Chemistry for Metals, Ores, and Related Materials and is the directresponsibility of Subcommittee E01.02 on Ores, Concentrates, and Related Metal-lurgical Materials.Current edition approved Dec. 15, 2011. Published January 2012. Originallya
14、pproved in 1982. Last previous edition approved in 2005 as E878 01 (2005).DOI: 10.1520/E0878-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Docume
15、nt Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Analytical Reagents of the American Chemical Society wheresuch specifications are available.3Other grades may be used,provided it is first ascertained
16、 that the reagent is of sufficienthigh purity to permit its use without lessening the accuracy ofthe determination.7.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water conformingto Type I or II of Specification D1193. Type III or IV may beused i
17、f they effect no measurable change in the blank orsample.7.3 Ascorbic Acid Solution (10 g/100 mL) (C6H8O6)Dissolve 10 g of ascorbic acid (C6H8O6) in water and dilute to100 mL. Prepare fresh as needed.7.4 Diantipyrylmethane Solution (15 g/L) C23H24O2N4H2ODissolve 15 g of the reagent in about 300 mL o
18、f waterand 30 mL of (H2SO4) (1 + 1) and dilute to 1 L with water. Ifa residue remains, filter and store the filtrate in a brown bottle.7.5 Ferric Ammonium Sulfate (100 g/L)Dissolve 100 g offerric ammonium sulfate Fe2(SO4)3(NH4)2SO4in 800 mL ofwater containing 5 mL of H2SO4(1 + 1) and dilute to 1 L w
19、ithwater.7.6 Potassium Pyrosulfate (K2S2O7).7.7 Sodium Tetraborate (Anhydrous) (Na2B4O7)Dry thecommercial sodium tetraborate at 60 C to 70 C, then at 160C, and finally calcine at 400 C.7.8 Sodium Tetraborate/Sodium Carbonate (Na2B4O7/Na2CO3) Fusion Mixture Mix 1 part of Na2B4O7and 1 partof Na2CO3and
20、 store in an airtight container.7.9 Standard Titanium Solution:7.9.1 Solution A (1 mL = 0.1 mg Ti)Transfer 0.1670 g ofTiO2(previously calcined at 900 C) to a platinum crucible,add3gto4gofK2S2O7, cover, and fuse at a temperature of600 C until a clear melt is obtained. Place the cooled crucibleand cov
21、er into a 250-mLbeaker, add 50 mLto 60 mLof H2SO4(1 + 9), and heat to dissolve the melt. Wash crucible and coverwith H2SO4(1 + 9) and remove, adding the washings to the250-mL beaker. Transfer the solution of a 1-L volumetric flask,dilute to volume with H2SO4(1 + 9), and mix.7.9.2 Solution B (1 mL =
22、0.02 mg Ti)Transfer 50.0 mL ofstandard titanium Solution A to a 250-mL volumetric flask,dilute to volume with H2SO4(1 + 9), and mix.8. Hazards8.1 For precautions to be observed in this test method, referto Practices E50.9. Sampling and Sample Preparation9.1 SamplingThe gross sample shall be collecte
23、d andprepared in accordance with Practice E877.9.2 Sample PreparationPulverize the laboratory sampleto pass a No. 100 (150-m) sieve.NOTE 2To facilitate decomposition, some ores such as specularhematite require grinding to pass a No. 200 (75-m) sieve.10.4.10. ProcedureNOTE 3If the procedure is based
24、on acid decomposition, use steps in10.1. If the procedure is based on alkaline sintering, use steps in 10.2.Ifthe procedure is based on alkaline fusion, use steps in 10.3.10.1 Acid Decomposition:10.1.1 Weigh approximately the amount of the test samplespecified in the table below into a small weighin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME87820113125STANDARDTESTMETHODFORDETERMINATIONOFTITANIUMINIRONORESANDRELATEDMATERIALSBYDIANTIPYRYLMETHANEULTRAVIOLETSPECTROMETRY

链接地址:http://www.mydoc123.com/p-533713.html